EN ISO 14403-2:2012
Current
The latest, up-to-date edition.
Water quality - Determination of total cyanide and free cyanide using flow analysis (FIA and CFA) - Part 2: Method using continuous flow analysis (CFA) (ISO 14403-2:2012)
15-07-2012
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Interferences
5 Principle
6 Reagents
7 Apparatus
8 Sampling and sample preparation
9 Procedure
10 Calculation
11 Expression of results
12 Test report
Annex A (informative) - Examples of flow systems
Annex B (normative) - Determination of the real
cyanide concentration in the potassium
cyanide solution
Annex C (informative) - Example for the determination
of total cyanide and free cyanide by
continuous flow analysis (CFA) with
gas diffusion and amperometric detection
Annex D (informative) - Performance data
Bibliography
ISO 14403-2:2012 specifies methods for the determination of cyanide in various types of water (such as ground, drinking, surface, leachate, and waste water) with cyanide concentrations usually from 2 µg/l to 500 µg/l expressed as cyanide ions in the undiluted sample. The range of application can be changed by varying the operation conditions, e.g. by diluting the original sample or changing the pathlength of the flow cell.In this method, a suitable mass concentration range from10 µg/l to 100 µg/l is described.Seawater can be analysed with possible changes in sensitivity and adaptation of the reagent and calibration solutions to the salinity of the samples.
Committee |
CEN/TC 230
|
DevelopmentNote |
Supersedes EN ISO 14403. (07/2012)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Supersedes |
Standards | Relationship |
UNE-EN ISO 14403-2:2013 | Identical |
DIN EN ISO 14403-2:2012-10 | Identical |
UNI EN ISO 14403-2 : 2013 | Identical |
NEN EN ISO 14403-2 : 2012 | Identical |
SS-EN ISO 14403-2:2012 | Identical |
SN EN ISO 14403-2 : 2012 | Identical |
NF EN ISO 14403-2 : 2012 | Identical |
ISO 14403-2:2012 | Identical |
NS EN ISO 14403-2 : 2012 | Identical |
NBN EN ISO 14403-2 : 2012 | Identical |
I.S. EN ISO 14403-2:2012 | Identical |
PN EN ISO 14403-2 : 2012 | Identical |
BS EN ISO 14403-2:2012 | Identical |
UNE-EN 15002:2015 | Characterization of waste - Preparation of test portions from the laboratory sample |
I.S. EN 15002:2015 | CHARACTERIZATION OF WASTE - PREPARATION OF TEST PORTIONS FROM THE LABORATORY SAMPLE |
13/30291099 DC : 0 | BS EN 15002 - CHARACTERIZATION OF WASTE - PREPARATION OF TEST PORTIONS FROM THE LABORATORY SAMPLE |
DIN EN 15002:2015-07 | CHARACTERIZATION OF WASTE - PREPARATION OF TEST PORTIONS FROM THE LABORATORY SAMPLE |
EN 15002:2015 | Characterization of waste - Preparation of test portions from the laboratory sample |
BS EN 15002:2015 | Characterization of waste. Preparation of test portions from the laboratory sample |
ISO 5667-3:2012 | Water quality Sampling Part 3: Preservation and handling of water samples |
ISO 8466-2:2001 | Water quality — Calibration and evaluation of analytical methods and estimation of performance characteristics — Part 2: Calibration strategy for non-linear second-order calibration functions |
ISO 5725-2:1994 | Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method |
ISO 3696:1987 | Water for analytical laboratory use — Specification and test methods |
NEN 6655 : 1997 | WATER AND SOIL - PHOTOMETRIC DETERMINATION OF THE CONTENT OF TOTAL AND FREE CYANIDE BY CONTINUOUS FLOW ANALYSIS |
ISO 8466-1:1990 | Water quality Calibration and evaluation of analytical methods and estimation of performance characteristics Part 1: Statistical evaluation of the linear calibration function |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.