• Shopping Cart
    There are no items in your cart

EN ISO 15587-1:2002

Current

Current

The latest, up-to-date edition.

Water quality - Digestion for the determination of selected elements in water - Part 1: Aqua regia digestion (ISO 15587-1:2002)

Published date

01-03-2002

Sorry this product is not available in your region.

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Principle
5 Reagents
6 Apparatus
7 Sampling
8 Procedure
9 Test report
Annex A (informative) Digestion in an open system using
        electrical heating
Annex B (informative) Digestion in an open system using
        microwave-assisted heating
Annex C (informative) Digestion in a closed system
        using microwave-assisted heating
Annex D (informative) Digestion in a closed system using
        an autoclave
Annex E (informative) Performance checks
Annex ZA (normative) Normative references to International
         Publications with their relevant European publications
Bibliography

This part of ISO 15587 specifies a method for extracting trace elements from a water sample using aqua regia as a digestion agent. The method is applicable to all types of waters with a suspended solids mass concentration of less than 20 g/l and a mass concentration of total organic carbon (TOC) expressed as carbon of less than 5 g/l. The aqua regia digestion method is empirical and it might not release elements completely. However, for most environmental applications, the result is fit for purpose.Aqua regia digestion is suitable for the release of: Ag, Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, Hg, K, Mg, Mn, Mo, Na, Ni, P, Pb, Sb, Se, Sn, Sr, Tl, V, Zn. It is not suitable for the digestion of refractory compounds such as SiO 2, TiO2 and Al2O3. The presence of chloride in the digestion solution may limit the application of analytical techniques.The method is generic and may be implemented using a wide variety of equipment provided the digestion composition is unchanged, the digestion temperature is known, and the digestion duration is in accordance with this temperature.

Committee
CEN/TC 230
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current

I.S. EN 1483:2007 WATER QUALITY - DETERMINATION OF MERCURY - METHOD USING ATOMIC ABSORPTION SPECTROMETRY
S.R. CLC/TS 50625-3-2:2016 COLLECTION, LOGISTICS & TREATMENT REQUIREMENTS FOR WEEE - PART 3-2: TECHNICAL SPECIFICATION FOR DE-POLLUTION - LAMPS
DIN EN 1483:2007-07 WATER QUALITY - DETERMINATION OF MERCURY - METHOD USING ATOMIC ABSORPTION SPECTROMETRY
BS 6068-2.84(2003) : 2003 WATER QUALITY - DETERMINATION OF TRACE ELEMENTS USING ATOMIC ABSORPTION SPECTROMETRY WITH GRAPHITE FURNACE
S.R. CLC/TS 50625-3-5:2017 COLLECTION, LOGISTICS & TREATMENT REQUIREMENTS FOR WEEE - PART 3-5: TECHNICAL SPECIFICATION FOR DE-POLLUTION - PHOTOVOLTAIC PANELS
07/30162524 DC : 0 BS ISO 7971-2 - CEREALS - DETERMINATION OF BULK DENSITY, CALLED MASS PER HECTOLITRE - PART 2: METHOD OF TRACEABILITY FOR MEASURING INSTRUMENTS THROUGH REFERENCE TO THE INTERNATIONAL STANDARD INSTRUMENT
CLC/TS 50625-3-5:2017 Collection, logistics & Treatment requirements for WEEE - Part 3-5: Technical specification for de-pollution - Photovoltaic panels
CLC/TS 50625-3-3:2017 Collection, logistics & treatment requirements for WEEE - Part 3-3: Specification for de-pollution - WEEE containing CRTs and flat panel displays
CLC/TS 50625-3-2:2016 Collection, logistics & Treatment requirements for WEEE - Part 3-2: Technical specification for de-pollution - Lamps
DIN EN 1483:1997-08 WATER QUALITY - DETERMINATION OF MERCURY - METHOD USING ATOMIC ABSORPTION SPECTROMETRY
S.R. CLC/TS 50625-3-3:2017 COLLECTION, LOGISTICS & TREATMENT REQUIREMENTS FOR WEEE - PART 3-3: SPECIFICATION FOR DE-POLLUTION - WEEE CONTAINING CRTS AND FLAT PANEL DISPLAYS
PD CLC/TS 50625-3-5:2017 Collection, logistics & Treatment requirements for WEEE Technical specification for de-pollution. Photovoltaic panels
PD CLC/TS 50625-3-3:2017 Collection, logistics & treatment requirements for WEEE Specification for de-pollution. WEEE containing CRTs and flat panel displays
BS 6068-2.89(2003) : 2003 WATER QUALITY - APPLICATION OF INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY (ICP-MS) - PART 2: DETERMINATION OF 62 ELEMENTS
BS EN 1483:2007 Water quality. Determination of mercury. Method using atomic absorption spectrometry
PD CLC/TS 50625-3-2:2016 Collection, logistics & treatment requirements for WEEE Technical specification for de-pollution. Lamps
CEI CLC/TS 50625-3-2 : 1ED 2017 COLLECTION, LOGISTICS & TREATMENT REQUIREMENTS FOR WEEE - PART 3-2: TECHNICAL SPECIFICATION FOR DE-POLLUTION - LAMPS
ISO 15586:2003 Water quality — Determination of trace elements using atomic absorption spectrometry with graphite furnace
EN ISO 15586:2003 Water quality - Determination of trace elements using atomic absorption spectrometry with graphite furnace (ISO 15586:2003)
EN 1483:2007 Water quality - Determination of mercury - Method using atomic absorption spectrometry
BS EN ISO 15586:2003 Water quality. Determination of trace elements using atomic absorption spectrometry with graphite furnace
DIN EN ISO 15586:2004-02 WATER QUALITY - DETERMINATION OF TRACE ELEMENTS USING ATOMIC ABSORPTION SPECTROMETRY WITH GRAPHITE FURNACE

ISO 11466:1995 Soil quality — Extraction of trace elements soluble in aqua regia
ISO 5667-3:2012 Water quality Sampling Part 3: Preservation and handling of water samples
EN 13346:2000 Characterization of sludges - Determination of trace elements and phosphorus - Aqua regia extraction methods
EN ISO 5667-3:2012 Water quality - Sampling - Part 3: Preservation and handling of water samples (ISO 5667-3:2012)
ISO 3696:1987 Water for analytical laboratory use — Specification and test methods
EN ISO 3696:1995 Water for analytical laboratory use - Specification and test methods (ISO 3696:1987)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.