EN ISO 15680:2003
Current
The latest, up-to-date edition.
Water quality - Gas-chromatographic determination of a number of monocyclic aromatic hydrocarbons, naphthalene and several chlorinated compounds using purge-and-trap and thermal desorption (ISO 15680:2003)
01-11-2003
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Principle
5 Interferences
6 Reagents
7 Apparatus
8 Sample collection, preservation and preparation
9 Analytical procedure
10 Calibration
11 Calculation
12 Expression of results
13 Precision data
14 Test report
Annex A (informative) - Application of purge-and-trap
concentration to the GC analysis of
volatile compounds in water - Example 1:
Validation study in the UK
Annex B (informative) - Application of purge-and-trap concentration
to the GC-analysis of volatile compounds
in water - Example 2: Data provided by DIN
Annex C (informative) - Application of purge-and-trap
concentration to the GC-analysis of
volatile compounds in water - Example 3:
Validation study in the Netherlands
Annex D (normative) - Criteria for the GC-MS identification
of target compounds
Annex E (informative) - Procedures for the cleaning of
glassware and the preparation of
contaminant-free water
Annex F (informative) - Preparation of standard solutions of
volatile organic compounds
Annex G (informative) - Determination of the (absolute)
recovery of substances analysed by
purge-and-trap concentration
Bibliography
ISO 15680:2003 specifies a general method for the determination of volatile organic compounds (VOCs) in water by purge-and-trap isolation and gas chromatography (GC). Annexes A, B and C provide examples of analytes that can be determined using ISO 15680:2003. They range from difluorodichloromethane (R-12) up to trichlorobenzene, including all non-polar organic compounds of intermediate volatility.Detection is preferably carried out by mass spectrometry in the electron impact mode (EI), but other detectors may be applied as well.The limit of detection largely depends on the detector in use and the operational parameters. Typically detection limits as low as 10 ng/l can be achieved. The working range typically is up to 100 micrograms per litre.ISO 15680:2003 is applicable to drinking water, ground water, surface water, seawater and to (diluted) waste water.
Committee |
CEN/TC 230
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
NF EN ISO 15680 : 2004 | Identical |
PN EN ISO 15680 : 2008 | Identical |
I.S. EN ISO 15680:2004 | Identical |
BS 6068-2.85(2003) : 2003 | Identical |
ISO 15680:2003 | Identical |
UNE-EN ISO 15680:2004 | Identical |
BS EN ISO 15680:2003 | Identical |
SN EN ISO 15680 : 2004 | Identical |
NBN EN ISO 15680 : 2004 | Identical |
NEN EN ISO 15680 : 2003 | Identical |
UNI EN ISO 15680 : 2005 | Identical |
NS EN ISO 15680 : 1ED 2004 | Identical |
DIN EN ISO 15680:2004-04 | Identical |
BS 6920-4:2001 | Suitability of non-metallic products for use in contact with water intended for human consumption with regard to their effect on the quality of the water Method for the GCMS identification of water leachable organic substances |
ISO 11423-1:1997 | Water quality — Determination of benzene and some derivatives — Part 1: Head-space gas chromatographic method |
ISO 5667-3:2012 | Water quality Sampling Part 3: Preservation and handling of water samples |
ISO 10301:1997 | Water quality — Determination of highly volatile halogenated hydrocarbons — Gas-chromatographic methods |
ISO 3696:1987 | Water for analytical laboratory use — Specification and test methods |
ISO 8466-1:1990 | Water quality Calibration and evaluation of analytical methods and estimation of performance characteristics Part 1: Statistical evaluation of the linear calibration function |
EN ISO 3696:1995 | Water for analytical laboratory use - Specification and test methods (ISO 3696:1987) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.