EN ISO 16000-9:2006
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Indoor air - Part 9: Determination of the emission of volatile organic compounds from building products and furnishing - Emission test chamber method (ISO 16000-9:2006)
01-08-2006
01-02-2006
ISO 16000-9:2006 specifies a general laboratory test method for determination of the area specific emission rate of volatile organic compounds (VOCs) from newly produced building products or furnishing under defined climate conditions. The method can also, in principle, be applied to aged products. The emission data obtained can be used to calculate concentrations in a model room. ISO 16000-9:2006 applies to various emission test chambers used for determination of the emission of volatile organic compounds from building products or products. A general description of an emission test chamber is given. ISO 16000-9:2006 is also applicable to wood-based panels and other building products, in order to determine the emission rate of formaldehyde.
Committee |
CEN/TC 264
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Withdrawn
|
Standards | Relationship |
UNE-EN ISO 16000-9:2006 | Identical |