EN ISO 23500-2:2019
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Preparation and quality management of fluids for haemodialysis and related therapies - Part 2: Water treatment equipment for haemodialysis applications and related therapies (ISO 23500-2:2019)
30-09-2019
20-03-2019
1.1 General This document is addressed to the manufacturer and/or supplier of water treatment systems and/or devices used for the express purpose of providing water for haemodialysis or related therapies.1.2 Inclusions This document covers devices used to treat potable water intended for use in the delivery of haemodialysis and related therapies, including water used for: a) the preparation of concentrates from powder or other highly concentrated media at a dialysis facility; b) the preparation of dialysis fluid, including dialysis fluid that can be used for the preparation of substitution fluid; c) the reprocessing of dialysers intended for single use where permitted for multiple uses, d) the reprocessing of dialysers not specifically marked as intended for single use. This document includes all devices, piping and fittings between the point at which potable water is delivered to the water treatment system, and the point of use of the dialysis water. Examples of the devices are water purification devices, online water quality monitors (such as conductivity monitors), and piping systems for the distribution of dialysis water.1.3 Exclusions This document excludes dialysis fluid supply systems that proportion water and concentrates to produce dialysis fluid, sorbent dialysis fluid regeneration systems that regenerate and recirculate small volumes of the dialysis fluid, dialysis concentrates, haemodiafiltration systems, haemofiltration systems, systems that process dialysers for multiple uses, and peritoneal dialysis systems. Some of these devices, such as dialysis fluid delivery systems and concentrates, are addressed in other documents such as ISO 23500-4 and ISO 23500‑5, This document also excludes the on-going surveillance of the purity of water used for dialysis fluid, concentrate preparation, or dialyser reprocessing which is addressed in ISO 23500‑1.
Committee |
CEN/TC 205
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Withdrawn
|
Supersedes |
Standards | Relationship |
DS/EN ISO 23500-2:2019 | Identical |
ISO 23500-2:2019 | Identical |
UNE-EN ISO 23500-2:2019 | Identical |
NEN-EN-ISO 23500-2:2019 | Identical |
ÖNORM EN ISO 23500-2:2019 09 15 | Identical |
SS-EN ISO 23500-2:2019 | Identical |
BS EN ISO 23500-2:2019 | Identical |
DIN EN ISO 23500-2:2019-11 | Identical |
SN EN ISO 23500-2:2019 | Identical |
NS-EN ISO 23500-2:2019 | Identical |
PN-EN ISO 23500-2:2019-07 | Identical |
I.S. EN ISO 23500-2:2019 | Identical |
UNI EN ISO 23500-2:2019 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.