0 Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
5 General requirements
6 Test rig and equipment
7 Qualification of test rig and apparatus
8 Test materials
9 Test procedure
10 Uncertainty calculation of the test results
11 Reporting
Annex A (normative) - Conditioning test procedure
Annex B (informative) - Shedding from filter elements
Annex C (informative) - Commentary
Annex D (normative) - Pressure drop calculation
Annex E (normative) - Net Area Calculation
Bibliography
ISO 29461 specifies methods and procedures for determining the performance of particulate air filters used in air intake filter systems for rotary machinery such as stationary gas turbines, compressors and other stationary internal combustion engines. It applies to air filters having an initial particle efficiency up to 99,9 % with respect to 0,4 µm particles. Filters with higher initial particle efficiencies are tested and classified according to other standards (e.g. EN 1822). These procedures are intended for filters which operating at flow rates within the range 0,25 m3/s (900 m3/h) up to 1,67 m3/s (6000 m3/h).ISO 29461-1:2013 refers to static (barrier) filter systems but can be applied to other filter types and systems in appropriate circumstances.Two methods of determining the efficiency are used in ISO 29461-1:2013:particulate efficiency (measured with respect to particle number and size); gravimetric efficiency (percentage weighted mass removal of loading dust. Also a flat sheet media sample or media pack sample from an identical filter is conditioned (discharged) to provide information about the intensity of the electrostatic removal mechanism.After determination of its initial particle efficiency, the untreated filter is loaded with dust in steps until its final test pressure drop is reached. Information on the loaded performance of the filter is then obtained.The performance results obtained in accordance with ISO 29461-1:2013 cannot be quantitatively applied (by themselves) to predict performance in service with regard to efficiency and lifetime. Other factors influencing performance to be taken into account are described in the annexes.
Committee |
CEN/TC 195
|
DevelopmentNote |
Supersedes PREN ISO 29461-1. (04/2013)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NS-EN ISO 29461-1:2021 | Identical |
ONORM EN ISO 29461-1 : 2014 | Identical |
NBN EN ISO 29461-1 : 2013 | Identical |
BS EN ISO 29461-1:2013 | Identical |
DIN EN ISO 29461-1:2014-03 | Identical |
NF EN ISO 29461-1 : 2013 | Identical |
I.S. EN ISO 29461-1:2013 | Identical |
NEN EN ISO 29461-1 : 2013 | Identical |
ISO 29461-1:2013 | Identical |
UNE-EN ISO 29461-1:2014 | Identical |
SN EN ISO 29461-1:2013 | Identical |
PN EN ISO 29461-1 : 2013 | Identical |
NS EN ISO 29461-1 : 2013 | Identical |
UNI EN ISO 29461-1 : 2013 | Identical |
ASTM F 328 : 1998 | Standard Practice for Calibration of an Airborne Particle Counter Using Monodisperse Spherical Particles |
ASHRAE 52.2 : 2017 | METHOD OF TESTING GENERAL VENTILATION AIR-CLEANING DEVICES FOR REMOVAL EFFICIENCY BY PARTICLE SIZE |
ISO 2854:1976 | Statistical interpretation of data — Techniques of estimation and tests relating to means and variances |
ASTM F 649 : 2001 | Standard Practice for Secondary Calibration of Airborne Particle Counter Using Comparison Procedures (Withdrawn 2007) |
EN 779:2012 | Particulate air filters for general ventilation - Determination of the filtration performance |
IEST RP CC001.4 : 2005 | HEPA AND ULPA FILTERS |
IEST RP CC014.2 : 2010 | CALIBRATION AND CHARACTERIZATION OF OPTICAL AIRBORNE PARTICLE COUNTERS |
ISO 14644-3:2005 | Cleanrooms and associated controlled environments Part 3: Test methods |
ASME MFC 3M : 2004 | MEASUREMENT OF FLUID FLOW IN PIPES USING ORIFICE, NOZZLE, AND VENTURI |
EN 1822-3:2009 | High efficiency air filters (EPA, HEPA and ULPA) - Part 3: Testing flat sheet filter media |
ISO/TS 21220:2009 | Particulate air filters for general ventilation Determination of filtration performance |
ISO 21501-4:2007 | Determination of particle size distribution Single particle light interaction methods Part 4: Light scattering airborne particle counter for clean spaces |
ISO 12103-1:2016 | Road vehicles — Test contaminants for filter evaluation — Part 1: Arizona test dust |
ISO 21501-1:2009 | Determination of particle size distribution — Single particle light interaction methods — Part 1: Light scattering aerosol spectrometer |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.