• Shopping Cart
    There are no items in your cart

EN ISO 5840-3:2013

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Cardiovascular implants - Cardiac valve prostheses - Part 3: Heart valve substitutes implanted by transcatheter techniques (ISO 5840-3:2013)

Superseded date

12-02-2021

Superseded by

EN ISO 5840-3:2021

Published date

06-03-2013

Sorry this product is not available in your region.

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Abbreviations
5 Fundamental requirements
6 Device description
7 Design verification testing and analysis/design
  validation
Annex A (informative) - Rationale for the provisions
        of this part of ISO 5840
Annex B (informative) - Examples of transcatheter heart
        valve substitutes, components and delivery systems
Annex C (normative) - Packaging
Annex D (normative) - Product labels, instructions for
        use and training
Annex E (normative) - Sterilization
Annex F (informative) - Valve description
Annex G (informative) - Transcatheter heart valve substitute
        hazards, associated failure modes and
        evaluation methods
Annex H (informative) - In vitro test guidelines for
        paediatric devices
Annex I (informative) - Statistical procedures when
        using performance criteria
Annex J (informative) - Examples and definitions of
        some physical and material properties of
        transcatheter heart valve substitutes and
        their components
Annex K (informative) - Examples of standards applicable
        to testing of materials and components of
         transcatheter heart valve substitutes
Annex L (informative) - Raw and post-conditioning
        mechanical properties for support structure
        materials
Annex M (informative) - Corrosion assessment
Annex N (informative) - Guidelines for verification of
        hydrodynamic performance
Annex O (informative) - Durability testing
Annex P (informative) - Fatigue assessment
Annex Q (informative) - Preclinical in vivo evaluation
Annex R (normative) - Adverse event classification
        during clinical investigation
Annex S (informative) - Echocardiographic protocol
Bibliography
Annex ZA (informative) - Relationship between this
         European Standard and the Essential
         Requirements of EU Directive 93/42/EEC

ISO 5840-3:2013 outlines an approach for verifying/validating the design and manufacture of a transcatheter heart valve substitute through risk management. The selection of appropriate verification/validation tests and methods are to be derived from the risk assessment. The tests may include those to assess the physical, chemical, biological and mechanical properties of heart valve substitutes and of their materials and components. The tests can also include those for preclinical in vivo evaluation and clinical evaluation of the finished heart valve substitute.ISO 5840-3:2013 defines operational conditions and performance requirements for transcatheter heart valve substitutes where adequate scientific and/or clinical evidence exists for their justification. ISO 5840-3:2013 is applicable to all devices intended for implantation in human hearts as a transcatheter heart valve substitute.ISO 5840-3:2013 is applicable to both newly developed and modified transcatheter heart valve substitutes and to the accessory devices, packaging and labelling required for their implantation and for determining the appropriate size of heart valve substitute to be implanted.

Committee
CEN/TC 285
DevelopmentNote
Supersedes PREN ISO 5840-3. (03/2013)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Superseded
SupersededBy

ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
ISO 11137-1:2006 Sterilization of health care products Radiation Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices
ISO 11607-2:2006 Packaging for terminally sterilized medical devices Part 2: Validation requirements for forming, sealing and assembly processes
ISO 14160:2011 Sterilization of health care products Liquid chemical sterilizing agents for single-use medical devices utilizing animal tissues and their derivatives Requirements for characterization, development, validation and routine control of a sterilization process for medical devices
ISO 5840:2005 Cardiovascular implants Cardiac valve prostheses
ASTM F 2503 : 2013 : REDLINE Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment
ISO 13485:2016 Medical devices Quality management systems Requirements for regulatory purposes
ISO 14937:2009 Sterilization of health care products General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices
ISO 10993-2:2006 Biological evaluation of medical devices — Part 2: Animal welfare requirements
ISO 25539-1:2017 Cardiovascular implants — Endovascular devices — Part 1: Endovascular prostheses
ISO 22442-1:2015 Medical devices utilizing animal tissues and their derivatives Part 1: Application of risk management
IEC 62366:2007+AMD1:2014 CSV Medical devices - Application of usability engineering to medical devices
ISO 11135-1:2007 Sterilization of health care products Ethylene oxide Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices
ISO 14630:2012 Non-active surgical implants — General requirements
ASTM F 2052 : 2015 : REDLINE Standard Test Method for Measurement of Magnetically Induced Displacement Force on Medical Devices in the Magnetic Resonance Environment
ISO 8601:2004 Data elements and interchange formats Information interchange Representation of dates and times
ISO/TS 11139:2006 Sterilization of health care products Vocabulary
ISO 11137-3:2017 Sterilization of health care products — Radiation — Part 3: Guidance on dosimetric aspects of development, validation and routine control
ASTM F 2213 : 2017 : REDLINE Standard Test Method for Measurement of Magnetically Induced Torque on Medical Devices in the Magnetic Resonance Environment
ISO 11137-2:2013 Sterilization of health care products — Radiation — Part 2: Establishing the sterilization dose
ISO 10993-1:2009 Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process
ISO 10555-1:2013 Intravascular catheters — Sterile and single-use catheters — Part 1: General requirements
ISO 22442-2:2015 Medical devices utilizing animal tissues and their derivatives Part 2: Controls on sourcing, collection and handling
ISO 14155:2011 Clinical investigation of medical devices for human subjects Good clinical practice
ISO 22442-3:2007 Medical devices utilizing animal tissues and their derivatives — Part 3: Validation of the elimination and/or inactivation of viruses and transmissible spongiform encephalopathy (TSE) agents
ISO/TS 11135-2:2008 Sterilization of health care products Ethylene oxide Part 2: Guidance on the application of ISO 11135-1
ISO 14971:2007 Medical devices Application of risk management to medical devices
ISO 11607-1:2006 Packaging for terminally sterilized medical devices Part 1: Requirements for materials, sterile barrier systems and packaging systems
ISO 17665-1:2006 Sterilization of health care products — Moist heat — Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.