Neurosurgical implants - Sterile, single-use hydrocephalus shunts and components (ISO 7197:2006, including Cor 1:2007)
21-03-2010
13-05-2009
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements for shunts
5 Specific requirements for components
6 Marking and labeling for shunts
7 Packaging
8 Information supplied by the manufacturer
Bibliography
Annex ZA (informative) - Relationship between this European
Standard and the Essential Requirements
of EU Directive 93/42/EEC
ISO 7197:2006 specifies safety and performance requirements for sterile, single-use non-active hydrocephalus shunts and components. This includes the components used in shunts, like valves, tubes and reservoirs.For manufacturing, ISO 7197:2006 defines the mechanical and technical requirements. This International Standard defines the technical information of the valve, to be given by the manufacturer. In respect to the different principles of the valve types, specific characteristics are defined for each group as declared by the manufacturer.The benefit of ISO 7197:2006 for the surgeon and the patient is to understand the information given by the manufacturer and to obtain standardized information about the performance of a well working product with new design characteristics. The benefit for the manufacturer is to define the important requirements for shunts as a basis for investigations during development as well as for quality control during manufacture.
Committee |
CEN/TC 285
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Withdrawn
|
Standards | Relationship |
ISO 7197:2006 | Identical |
NBN EN ISO 7197 : 2009 | Identical |
NEN EN ISO 7197 : 2009 | Identical |
NS EN ISO 7197 : 2009 | Identical |
I.S. EN ISO 7197:2009 | Identical |
PN EN ISO 7197 : 2009 | Identical |
SN EN ISO 7197 : 2009 | Identical |
UNI EN ISO 7197 : 2009 | Identical |
UNE-EN ISO 7197:2009 | Identical |
BS EN ISO 7197:2009 | Identical |
NF EN ISO 7197 : 2009 | Identical |
DIN EN ISO 7197:2009-08 | Identical |
DS EN ISO 7197 : 2009 | Identical |
ISO 14155-2:2003 | Clinical investigation of medical devices for human subjects Part 2: Clinical investigation plans |
ISO 11135:2014 | Sterilization of health-care products — Ethylene oxide — Requirements for the development, validation and routine control of a sterilization process for medical devices |
ASTM F 2503 : 2013 : REDLINE | Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment |
ISO 14155-1:2003 | Clinical investigation of medical devices for human subjects Part 1: General requirements |
ISO 14630:2012 | Non-active surgical implants — General requirements |
ISO 10993-1:2009 | Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process |
ISO 11134:1994 | Sterilization of health care products — Requirements for validation and routine control — Industrial moist heat sterilization |
ISO 14971:2007 | Medical devices Application of risk management to medical devices |
ISO 11137:1995 | Sterilization of health care products Requirements for validation and routine control Radiation sterilization |
ASTM F 640 : 2012 : REDLINE | Standard Test Methods for Determining Radiopacity for Medical Use |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.