EN ISO 7393-2:2018
Current
The latest, up-to-date edition.
Water quality - Determination of free chlorine and total chlorine - Part 2: Colorimetric method using N,N-dialkyl-1,4-phenylenediamine, for routine control purposes (ISO 7393-2:2017)
31-01-2018
European foreword
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Principle
5 Interferences
6 Reagents
7 Apparatus
8 Sampling
9 Procedure
10 Calculation
11 Expression of results
12 Test report
Annex A (informative) - Separate determinations of combined
chlorine of the monochloramine type, combined
chlorine of the dichloramine type and of
combined chlorine in the form of nitrogen trichloride
Annex B (informative) - Performance data
Annex C (informative) - Disposable planar reagent-filled
cuvettes using a mesofluidic channel pump/colorimeter
Bibliography
ISO 7393-2:2017 specifies a method for the determination of free chlorine and total chlorine in water, readily applicable to lab- and field-testing. It is based on measurement of the absorption, the red DPD colour complex in a photometer or the colour intensity by visual comparison of the colour with a scale of standards that is regularly calibrated.This method is appropriate for drinking water and other waters, where additional halogens like bromine, iodine and other oxidizing agents are present in almost negligible amounts. Seawater and waters containing bromides and iodides comprise a group for which special procedures are to be carried out.This method is in practice applicable to concentrations, in terms of chlorine (Cl2), from, for example, 0,000 4 mmol/l to 0,07 mmol/l (e.g. 0,03 mg/l to 5 mg/l) total chlorine. For higher concentrations, the test portion is diluted.Commonly, the method is applied as a field method with mobile photometers and commercially available ready-for-use reagents (liquid reagents, powders and tablets). It is essential that those reagents comply with minimum requirements and contain the essential reagents and a buffer system suitable to adjust the measurement solution to a pH range of typically 6,2 to 6,5. If there is doubt that water samples have uncommon pH values and/or buffer capacities, the user has to check and, if necessary, to adjust the sample pH to the required range. The pH of the sample is within the range of pH 4 and 8. Adjust, if necessary, with sodium hydroxide solution or sulfuric acid before the test.A procedure for the differentiation of combined chlorine of the monochloramine type, combined chlorine of the dichloramine type and combined chlorine in the form of nitrogen trichloride is presented in Annex A. In Annex C, a procedure is presented for the determination of free and total chlorine in drinking and other low polluted waters, for disposable planar reagent-filled cuvettes using a mesofluidic channel pump/colorimeter.
Committee |
CEN/TC 230
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
DIN EN ISO 7393-2:2019-03 | Identical |
DIN EN ISO 7393-2:2000-04 | Identical |
SS-EN ISO 7393-2 : 2018 | Identical |
BS EN ISO 7393-2:2000 | Identical |
PN EN ISO 7393-2 : 2018 | Identical |
NF EN ISO 7393-2 : 2018 | Identical |
NS EN ISO 7393-2 : 2018 | Identical |
SN EN ISO 7393-2 : 2000 | Identical |
ONORM EN ISO 7393-2 : 2000 | Identical |
ONORM EN ISO 7393-2 : 2019 | Identical |
UNI EN ISO 7393-2 : 2002 | Identical |
I.S. EN ISO 7393-2:2018&LC:2018 | Identical |
BS 6068-2.26(1986) : 1986 AMD 10870 | Identical |
NBN EN ISO 7393-2 : 2000 | Identical |
UNI EN ISO 7393-2 : 2018 | Identical |
NEN EN ISO 7393-2 : 2018 | Identical |
ISO 7393-2:1985 | Identical |
SN EN ISO 7393-2:2018 | Identical |
ISO 7393-2:2017 | Identical |
I.S. EN ISO 7393-2:2000 | Identical |
UNE-EN ISO 7393-2:2000 | Identical |
UNE-EN ISO 7393-2:2019 | Identical |
BS EN ISO 7393-2:2018 | Identical |
ISO 5667-3:2012 | Water quality Sampling Part 3: Preservation and handling of water samples |
ISO 5667-1:2006 | Water quality Sampling Part 1: Guidance on the design of sampling programmes and sampling techniques |
ISO 3696:1987 | Water for analytical laboratory use — Specification and test methods |
ISO 8466-1:1990 | Water quality Calibration and evaluation of analytical methods and estimation of performance characteristics Part 1: Statistical evaluation of the linear calibration function |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.