EN ISO 9073-12:2004
Current
The latest, up-to-date edition.
Textiles - Test methods for nonwovens - Part 12: Demand absorbency (ISO 9073-12:2002)
22-12-2004
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Principle
5 Apparatus
6 Assembly of the apparatus
7 Preparation and conditioning of test pieces
8 Procedure
9 Expression of the results
10 Test report
Annex A (normative) Determination of flow through
the porous medium using the data acquisition
system
Annex B (informative) MAR calculation explanation
Annex C (informative) Precision
ISO 9073-12 describes a method for the evaluation of the absorbency of fabrics when one side is in contact with a liquid and the fabric is under mechanical pressure.This test is designed to allow comparison of absorbent materials such as nonwovens and is not intended to simulate in-use conditions of finished products.Demand absorbency is also called demand wettability.
Committee |
CEN/TC 248
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
NF EN ISO 9073-12 : 2005 | Identical |
ISO 9073-12:2002 | Identical |
UNE-EN ISO 9073-12:2005 | Identical |
I.S. EN ISO 9073-12:2005 | Identical |
SN EN ISO 9073-12 : 2005 | Identical |
UNI EN ISO 9073-12 : 2005 | Identical |
NBN EN ISO 9073-12 : 2005 | Identical |
NEN EN ISO 9073-12 : 2005 | Identical |
SS-EN ISO 9073-12:2005 | Identical |
PN EN ISO 9073-12 : 2006 | Identical |
NS EN ISO 9073-12 : 1ED 2005 | Identical |
DIN EN ISO 9073-12:2005-03 | Identical |
BS ISO 9073-12:2002 | Identical |
PREN 13795-1 : DRAFT 2017 | SURGICAL CLOTHING AND DRAPES - REQUIREMENTS AND TEST METHODS - PART 1: SURGICAL DRAPES AND GOWNS |
17/30358658 DC : 0 | BS EN 13795-1 - SURGICAL CLOTHING AND DRAPES - REQUIREMENTS AND TEST METHODS - PART 1: SURGICAL DRAPES AND GOWNS |
BS EN 13795:2011+A1:2013 | Surgical drapes, gowns and clean air suits, used as medical devices for patients, clinical staff and equipment. General requirements for manufacturers, processors and products, test methods, performance requirements and performance levels |
UNI EN 13795 : 2013 | SURGICAL DRAPES, GOWNS AND CLEAN AIR SUITS, USED AS MEDICAL DEVICES FOR PATIENTS, CLINICAL STAFF AND EQUIPMENT - GENERAL REQUIREMENTS FOR MANUFACTURERS, PROCESSORS AND PRODUCTS, TEST METHODS, PERFORMANCE REQUIREMENTS AND PERFORMANCE LEVELS |
DIN EN 13795:2013-10 | SURGICAL DRAPES, GOWNS AND CLEAN AIR SUITS, USED AS MEDICAL DEVICES FOR PATIENTS, CLINICAL STAFF AND EQUIPMENT - GENERAL REQUIREMENTS FOR MANUFACTURERS, PROCESSORS AND PRODUCTS, TEST METHODS, PERFORMANCE REQUIREMENTS AND PERFORMANCE LEVELS |
09/30190221 DC : 0 | BS EN 13795 - SURGICAL DRAPES, GOWNS AND CLEAN AIR SUITS, USED AS MEDICAL DEVICES, FOR PATIENTS, CLINICAL STAFF AND EQUIPMENT - GENERAL REQUIREMENTS FOR MANUFACTURERS, PROCESSORS AND PRODUCTS, TEST METHODS, PERFORMANCE REQUIREMENTS AND PERFORMANCE LEVELS |
I.S. EN 13795:2011 | SURGICAL DRAPES, GOWNS AND CLEAN AIR SUITS, USED AS MEDICAL DEVICES FOR PATIENTS, CLINICAL STAFF AND EQUIPMENT - GENERAL REQUIREMENTS FOR MANUFACTURERS, PROCESSORS AND PRODUCTS, TEST METHODS, PERFORMANCE REQUIREMENTS AND PERFORMANCE LEVELS |
UNE-EN 13795:2011 | Surgical drapes, gowns and clean air suits, used as medical devices for patients, clinical staff and equipment - General requirements for manufacturers, processors and products, test methods, performance requirements and performance levels |
EN 13795:2011+A1:2013 | Surgical drapes, gowns and clean air suits, used as medical devices for patients, clinical staff and equipment - General requirements for manufacturers, processors and products, test methods, performance requirements and performance levels |
ISO 3696:1987 | Water for analytical laboratory use — Specification and test methods |
ISO 139:2005 | Textiles — Standard atmospheres for conditioning and testing |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.