ENV 1452-6 : DRAFT 2001
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 6: GUIDANCE FOR INSTALLATION
20-05-2010
12-01-2013
Introduction
1 Scope
2 Normative references
3 Definitions, symbols and abbreviations
4 Parameters influencing design
4.1 Allowable operating pressure
4.2 Ring stiffness of pipes
4.3 Precautions
5 Hydraulic properties
5.1 Loss of head
5.2 Internal diameter
6 Assembly methods
6.1 General
6.2 Integral rubber ring joints
6.3 Solvent cement joints
6.4 Mechanical joints
7 Cold bending on site
8 Storage, handling and transport of pipes
8.1 Storage
8.2 Handling
8.3 Transportation of loose pipes
9 Storage, handling and transport of fittings,
valves and ancillaries
10 Installation
10.1 General
10.2 Installation below ground
10.3 Installation above ground
10.4 Installation in ducts
11 Site pressure testing
11.1 General
11.2 Preparation for test
11.3 Test press
11.4 Applying the test
11.5 Interpretation of results
12 Corrosion protection
13 Pressure surge
14 Repairs
15 Pipeline detection
Annex A (informative) Hydraulic flow chart
Annex B (normative) Figures and tables referred to
in this prestandard
Provides recommended practices for installation of unplasticized poly(vinyl chloride) (PVC-U) pipes, fittings, valves and ancillaries when used in piping systems conveying water under pressure.
Committee |
TC 155
|
DocumentType |
Draft
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Withdrawn
|
Standards | Relationship |
DIN V ENV 1452-6:2002-03 | Identical |
NBN ENV 1452-6 : 2002 | Identical |
NF ENV 1452-6 : 2002 XP | Identical |
PN ENV 1452-6 : 2002 | Identical |
UNE-ENV 1452-6:2002 | Identical |
NEN NVN ENV 1452-6 : 2001 | Identical |
DD ENV 1452-6:2002 | Identical |
I.S. ENV 1452-6:2002 | Identical |
UNI ENV 1452-6 : 2003 | Identical |
BS EN 1452-2 : 2000 | PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 2: PIPES |
BS EN 1452-4 : 2000 | PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 4: VALVES AND ANCILLARY EQUIPMENT |
DIN EN 1452-5:1999-09 | PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 5: FITNESS FOR PURPOSE OF THE SYSTEM |
DIN EN 1452-4:1999-09 | PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 4: VALVES AND ANCILLARY EQUIPMENT |
DIN EN 1456-1:2001-12 | PLASTICS PIPING SYSTEMS FOR BURIED AND ABOVE-GROUND DRAINAGE AND SEWERAGE UNDER PRESSURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPING COMPONENTS AND THE SYSTEM |
DIN EN 1452-2:1999-09 | PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 2: PIPES |
DIN EN 1452-3:1999-09 | PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 3: FITTINGS |
08/30168702 DC : DRAFT JULY 2008 | BS EN ISO 1452-5 - PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE-GROUND DRAINAGE AND SEWERAGE UNDER PRESSURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 5: FITNESS FOR PURPOSE OF THE SYSTEM |
08/30168675 DC : DRAFT JULY 2008 | BS EN ISO 1452-2 - PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE-GROUND DRAINAGE AND SEWERAGE UNDER PRESSURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC U) - PART 2: PIPES |
DIN EN 12842:2012-11 | Ductile iron fittings for PVC-U or PE piping systems - Requirements and test methods |
I.S. EN 12842:2012 | DUCTILE IRON FITTINGS FOR PVC-U OR PE PIPING SYSTEMS - REQUIREMENTS AND TEST METHODS |
08/30185535 DC : DRAFT JULY 2008 | BS EN ISO 1452-1 - PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE-GROUND DRAINAGE AND SEWERAGE UNDER PRESSURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC U) - PART 1: GENERAL |
08/30168693 DC : DRAFT JULY 2008 | BS EN ISO 1452-4 - PLASTICS PIPING SYSTEMS FOR WATER SUPPLY AND FOR BURIED AND ABOVE-GROUND DRAINAGE AND SEWERAGE UNDER PRESSURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC U) - PART 4: VALVES |
BS EN 1452-3 : 2000 | PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 3: FITTINGS |
UNE-EN 12842:2013 | Ductile iron fittings for PVC-U or PE piping systems - Requirements and test methods |
UNI EN 12842 : 2012 | DUCTILE IRON FITTINGS FOR PVC-U OR PE PIPING SYSTEMS - REQUIREMENTS AND TEST METHODS |
EN 1456-1 : 2001 | PLASTICS PIPING SYSTEMS FOR BURIED AND ABOVE-GROUND DRAINAGE AND SEWERAGE UNDER PRESSURE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: SPECIFICATIONS FOR PIPING COMPONENTS AND THE SYSTEM |
EN 1452-4 : 1999 | PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 4: VALVES AND ANCILLARY EQUIPMENT |
EN 1452-2 : 1999 | PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 2: PIPES |
EN 12842:2012 | Ductile iron fittings for PVC-U or PE piping systems - Requirements and test methods |
EN 1452-3 : 1999 | PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 3: FITTINGS |
EN 1452-5 : 1999 | PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 5: FITNESS FOR PURPOSE OF THE SYSTEM |
BS EN 1452-5 : 2000 | PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 5: FITNESS FOR PURPOSE OF THE SYSTEM |
BS EN 12842:2012 | Ductile iron fittings for PVC-U or PE piping systems. Requirements and test methods |
ISO 7387-1:1983 | Adhesives with solvents for assembly of PVC-U pipe elements Characterization Part 1: Basic test methods |
EN 1452-4 : 1999 | PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 4: VALVES AND ANCILLARY EQUIPMENT |
EN 1452-1 : 1999 | PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: GENERAL |
EN 1452-2 : 1999 | PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 2: PIPES |
EN 1452-3 : 1999 | PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 3: FITTINGS |
ENV 1046:2001 | Plastics piping and ducting systems - Systems outside building structures for the conveyance of water or sewage - Practices for installation above and below ground |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.