Foreword
1 Scope
2 Normative references
3 Definitions
4 Test installation
      4.1 Test rig
      4.2 Impacting unit
      4.3 Impactor
      4.4 Test room climate
      4.5 Measuring equipment
5 Test specimen
      5.1 General
      5.2 Preparation and examination of the test specimen
6 Procedure
      6.1 Impact points
      6.2 Impact direction
      6.3 Loading procedure
      6.4 Measurement procedure
      6.5 Tolerances
7 Test results
8 Test report

This European Prestandard specifies a test method for the determination of resistance to dynamic loading in order to assess the burglar resistant properties of doors, windows and shutters.

Committee
CEN/TC 33
DocumentType
Standard Recommendation
PublisherName
Comite Europeen de Normalisation
Status
Withdrawn
SupersededBy

Standards Relationship
DD ENV 1629:1999 Identical
NF ENV 1629 : 99 XP Identical
UNI ENV 1629 : 2000 Identical
DIN V ENV 1629:1999-04 Identical
I.S. ENV 1629:1999 Identical
NEN ENV 1629 : 1999 Identical
PN ENV 1629 : 2006 Identical
NBN ENV 1629 : 1999 Identical
UNE-ENV 1629:2000 Identical
DD ENV 1628:1999 Identical

CEN/TR 16705:2014 Perimeter protection - Performance classification methodology
ENV 1628:1999 Windows, doors, shutters - Burglar resistance - Test method for the determination of resistance under static loading
I.S. EN 13126-1:2011 BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 1: REQUIREMENTS COMMON TO ALL TYPES OF HARDWARE
EN 13126-1:2011 Building hardware - Hardware for windows and door height windows - Requirements and test methods - Part 1: Requirements common to all types of hardware
CEN/TS 13126-1:2004 Building hardware, fittings for windows and door height windows - Requirements and test methods - Part 1: Requirements common to all types of fittings
UNI EN 13126-1 : 2012 BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 1: REQUIREMENTS COMMON TO ALL TYPES OF HARDWARE
ENV 1627:1999 Windows, doors, shutters - Burglar resistance - Requirements and classification
10/30218923 DC : DRAFT JUNE 2010 BS EN 13126-1 - BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 1: REQUIREMENTS COMMON TO ALL TYPES OF HARDWARE
PD CEN/TR 16705:2014 Perimeter protection. Performance classification methodology
DD CEN/TS 14383-3:2005 Prevention of crime. Urban planning and building design Dwellings
S.R. CEN/TS 14383-3:2005 PREVENTION OF CRIME - URBAN PLANNING AND BUILDING DESIGN - PART 3: DWELLINGS
I.S. EN 14351-1:2006 WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 1: WINDOWS AND EXTERNAL PEDESTRIAN DOORSETS WITHOUT RESISTANCE TO FIRE AND/OR SMOKE LEAKAGE CHARACTERISTICS
BS 6510:2005 Steel-framed windows and glazed doors
DD ENV 1630:1999 Windows, doors, shutters. Burglar resistance. Test method for the determination of resistance to manual burglary attempts
UNI CEN/TS 14383-3 : 2006 PREVENTION OF CRIME - URBAN PLANNING AND BUILDING DESIGN - PART 3: DWELLINGS
I.S. ENV 1627:1999 WINDOWS, DOORS, SHUTTERS - BURGLAR RESISTANCE - REQUIREMENTS AND CLASSIFICATION
I.S. TS 13126-1:2004 BUILDING HARDWARE, FITTINGS FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 1: REQUIREMENTS COMMON TO ALL TYPES OF FITTINGS
DIN EN 13126-1:2012-02 Building hardware - Hardware for windows and door height windows - Requirements and test methods - Part 1: Requirements common to all types of hardware
UNE-EN 13126-1:2012 Building hardware - Hardware for windows and door height windows - Requirements and test methods - Part 1: Requirements common to all types of hardware
11/30241851 DC : 0 BS EN 13659 - SHUTTERS AND EXTERNAL VENETIAN BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY
04/30100932 DC : DRAFT AUG 2004 BS 6510 - STEEL-FRAMED WINDOWS AND GLAZED DOORS
DD CEN/TS 13126-1:2004 Building hardware, fittings for windows and door height windows. Requirements and test methods Requirements common to all types of fittings
DD ENV 1627:1999 Windows, doors, shutters. Burglar resistance. Requirements and classification
S.R. CEN/TR 16705:2014 PERIMETER PROTECTION - PERFORMANCE CLASSIFICATION METHODOLOGY
BS EN 13126-1:2011 Building hardware. Hardware for windows and door height windows. Requirements and test methods Requirements common to all types of hardware
BS EN 14351-1 : 2006 WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 1: WINDOWS AND EXTERNAL PEDESTRIAN DOORSETS
EN 14351-1:2006+A2:2016 Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets
ENV 1630:1999 Windows, doors, shutters - Burglar resistance - Test method for the determination of resistance to manual burglary attempts
DD ENV 1628:1999 Windows, doors, shutters. Burglar resistance. Test method for the determination of resistance under static loading
UNE-CEN/TS 14383-3:2011 EX Prevention of crime - Urban planning and building design - Part 3: Dwellings
CEN/TS 14383-3:2005 Prevention of crime - Urban planning and building design - Part 3: Dwellings
UNE-EN 14351-1:2006 Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets without resistance to fire and/or smoke leakage characteristics

ENV 1630:1999 Windows, doors, shutters - Burglar resistance - Test method for the determination of resistance to manual burglary attempts
ENV 1628:1999 Windows, doors, shutters - Burglar resistance - Test method for the determination of resistance under static loading
ENV 1627:1999 Windows, doors, shutters - Burglar resistance - Requirements and classification

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.