• There are no items in your cart

ENV 1629:1999

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by

Windows, doors, shutters - Burglar resistance - Test method for the determination of resistance under dynamic loading

Withdrawn date

07-03-2023

Superseded by

EN 1629:2011+A1:2015

Published date

20-01-1999

Sorry this product is not available in your region.

Foreword
1 Scope
2 Normative references
3 Definitions
4 Test installation
      4.1 Test rig
      4.2 Impacting unit
      4.3 Impactor
      4.4 Test room climate
      4.5 Measuring equipment
5 Test specimen
      5.1 General
      5.2 Preparation and examination of the test specimen
6 Procedure
      6.1 Impact points
      6.2 Impact direction
      6.3 Loading procedure
      6.4 Measurement procedure
      6.5 Tolerances
7 Test results
8 Test report

This European Prestandard specifies a test method for the determination of resistance to dynamic loading in order to assess the burglar resistant properties of doors, windows and shutters.

Committee
CEN/TC 33
DocumentType
Standard Recommendation
PublisherName
Comite Europeen de Normalisation
Status
Withdrawn
SupersededBy

Standards Relationship
DD ENV 1629:1999 Identical
NF ENV 1629 : 99 XP Identical
UNI ENV 1629 : 2000 Identical
DIN V ENV 1629:1999-04 Identical
I.S. ENV 1629:1999 Identical
NEN ENV 1629 : 1999 Identical
PN ENV 1629 : 2006 Identical
NBN ENV 1629 : 1999 Identical
UNE-ENV 1629:2000 Identical
DD ENV 1628:1999 Identical

CEN/TR 16705:2014 Perimeter protection - Performance classification methodology
ENV 1628:1999 Windows, doors, shutters - Burglar resistance - Test method for the determination of resistance under static loading
I.S. EN 13126-1:2011 BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 1: REQUIREMENTS COMMON TO ALL TYPES OF HARDWARE
EN 13126-1:2011 Building hardware - Hardware for windows and door height windows - Requirements and test methods - Part 1: Requirements common to all types of hardware
CEN/TS 13126-1:2004 Building hardware, fittings for windows and door height windows - Requirements and test methods - Part 1: Requirements common to all types of fittings
UNI EN 13126-1 : 2012 BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 1: REQUIREMENTS COMMON TO ALL TYPES OF HARDWARE
ENV 1627:1999 Windows, doors, shutters - Burglar resistance - Requirements and classification
10/30218923 DC : DRAFT JUNE 2010 BS EN 13126-1 - BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 1: REQUIREMENTS COMMON TO ALL TYPES OF HARDWARE
PD CEN/TR 16705:2014 Perimeter protection. Performance classification methodology
DD CEN/TS 14383-3:2005 Prevention of crime. Urban planning and building design Dwellings
S.R. CEN/TS 14383-3:2005 PREVENTION OF CRIME - URBAN PLANNING AND BUILDING DESIGN - PART 3: DWELLINGS
I.S. EN 14351-1:2006 WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 1: WINDOWS AND EXTERNAL PEDESTRIAN DOORSETS WITHOUT RESISTANCE TO FIRE AND/OR SMOKE LEAKAGE CHARACTERISTICS
BS 6510:2005 Steel-framed windows and glazed doors
DD ENV 1630:1999 Windows, doors, shutters. Burglar resistance. Test method for the determination of resistance to manual burglary attempts
UNI CEN/TS 14383-3 : 2006 PREVENTION OF CRIME - URBAN PLANNING AND BUILDING DESIGN - PART 3: DWELLINGS
I.S. ENV 1627:1999 WINDOWS, DOORS, SHUTTERS - BURGLAR RESISTANCE - REQUIREMENTS AND CLASSIFICATION
I.S. TS 13126-1:2004 BUILDING HARDWARE, FITTINGS FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 1: REQUIREMENTS COMMON TO ALL TYPES OF FITTINGS
DIN EN 13126-1:2012-02 Building hardware - Hardware for windows and door height windows - Requirements and test methods - Part 1: Requirements common to all types of hardware
UNE-EN 13126-1:2012 Building hardware - Hardware for windows and door height windows - Requirements and test methods - Part 1: Requirements common to all types of hardware
11/30241851 DC : 0 BS EN 13659 - SHUTTERS AND EXTERNAL VENETIAN BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY
04/30100932 DC : DRAFT AUG 2004 BS 6510 - STEEL-FRAMED WINDOWS AND GLAZED DOORS
DD CEN/TS 13126-1:2004 Building hardware, fittings for windows and door height windows. Requirements and test methods Requirements common to all types of fittings
DD ENV 1627:1999 Windows, doors, shutters. Burglar resistance. Requirements and classification
S.R. CEN/TR 16705:2014 PERIMETER PROTECTION - PERFORMANCE CLASSIFICATION METHODOLOGY
BS EN 13126-1:2011 Building hardware. Hardware for windows and door height windows. Requirements and test methods Requirements common to all types of hardware
BS EN 14351-1 : 2006 WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 1: WINDOWS AND EXTERNAL PEDESTRIAN DOORSETS
EN 14351-1:2006+A2:2016 Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets
ENV 1630:1999 Windows, doors, shutters - Burglar resistance - Test method for the determination of resistance to manual burglary attempts
DD ENV 1628:1999 Windows, doors, shutters. Burglar resistance. Test method for the determination of resistance under static loading
UNE-CEN/TS 14383-3:2011 EX Prevention of crime - Urban planning and building design - Part 3: Dwellings
CEN/TS 14383-3:2005 Prevention of crime - Urban planning and building design - Part 3: Dwellings
UNE-EN 14351-1:2006 Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets without resistance to fire and/or smoke leakage characteristics

ENV 1630:1999 Windows, doors, shutters - Burglar resistance - Test method for the determination of resistance to manual burglary attempts
ENV 1628:1999 Windows, doors, shutters - Burglar resistance - Test method for the determination of resistance under static loading
ENV 1627:1999 Windows, doors, shutters - Burglar resistance - Requirements and classification

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.