ENVIRONMENTAL ENGINEERING (EE); MONITORING AND CONTROL INTERFACE FOR INFRASTRUCTURE EQUIPMENT (POWER, COOLING AND ENVIRONMENT SYSTEMS USED IN TELECOMMUNICATION NETWORKS); PART 2: DC POWER SYSTEM CONTROL AND MONITORING INFORMATION MODEL

Available format(s)

Hardcopy , PDF

Language(s)

English

€17.53
Excluding VAT

Intellectual Property Rights
Foreword
1 Scope
2 References
  2.1 Normative references
  2.2 Informative references
3 Definitions and abbreviations
  3.1 Definitions
  3.2 Abbreviations
4 DC power supply system
Annex A (normative): Summary of mandatory monitoring/supervision
        information and functions
      A.1 DC POWER SUPPLY SYSTEMS
Annex B (informative): Summary of non-mandatory
        monitoring/supervision information and functions
      B.1 DC power supply system without back-up
      B.2 DC power supply system with back-up
      B.3 DC power supply rectifier
Annex C (normative): Mandatory XML structure and elements
      C.1 Structure of an XML document for a DC power supply system
      C.2 The specific XML elements of a DC power supply system
Annex D (informative): Examples of XML elements for a DC power
        supply system
      D.1 The elements of a DC power supply system
      D.2 The elements of a DC power supply system
      D.3 The elements of a DC power supply system
      D.4 The elements of a DC power supply system
      D.5 The elements of a DC power supply system
      D.6 The elements of a DC power supply system
      D.7 The elements of a DC power supply system
      D.8 The elements of a DC power supply rectifier
      D.9 The elements of a DC power supply rectifier
      D.10 The elements of a DC power supply rectifier
      D.11 The elements of a DC power supply rectifier
      D.12 The elements of a DC power supply rectifier
      D.13 The elements of a DC power supply rectifier
Annex E (informative): Bibliography
History

Applicable to monitoring and control of DC power supply systems for telecommunication equipment.

Committee
EE 02
DocumentType
Standard
Pages
26
PublisherName
European Telecommunications Standards Institute
Status
Current

ES 202 336-6 : 1.1.1 ENVIRONMENTAL ENGINEERING (EE); MONITORING AND CONTROL INTERFACE FOR INFRASTRUCTURE EQUIPMENT (POWER, COOLING AND BUILDING ENVIRONMENT SYSTEMS USED IN TELECOMMUNICATION NETWORKS); PART 6: AIR CONDITIONING SYSTEM CONTROL AND MONITORING INFORMATION MODEL
ES 202 336-5 : 1.1.1 ENVIRONMENTAL ENGINEERING (EE); MONITORING AND CONTROL INTERFACE FOR INFRASTRUCTURE EQUIPMENT (POWER, COOLING AND BUILDING ENVIRONMENT SYSTEMS USED IN TELECOMMUNICATION NETWORKS); PART 5: AC DIESEL BACK-UP GENERATOR SYSTEM CONTROL AND MONITORING INFORMATION MODEL
ES 202 336-10 : 1.1.1 ENVIRONMENTAL ENGINEERING (EE); MONITORING AND CONTROL INTERFACE FOR INFRASTRUCTURE EQUIPMENT (POWER, COOLING AND BUILDING ENVIRONMENT SYSTEMS USED IN TELECOMMUNICATION NETWORKS); PART 10: AC INVERTER POWER SYSTEM CONTROL AND MONITORING INFORMATION MODEL
ES 202 336-4 : 1.1.1 ENVIRONMENTAL ENGINEERING (EE); MONITORING AND CONTROL INTERFACE FOR INFRASTRUCTURE EQUIPMENT (POWER, COOLING AND BUILDING ENVIRONMENT SYSTEMS USED IN TELECOMMUNICATION NETWORKS); PART 4: AC DISTRIBUTION POWER SYSTEM CONTROL AND MONITORING INFORMATION MODEL
ES 202 336-1 : 1.2.1 ENVIRONMENTAL ENGINEERING (EE); MONITORING AND CONTROL INTERFACE FOR INFRASTRUCTURE EQUIPMENT (POWER, COOLING AND BUILDING ENVIRONMENT SYSTEMS USED IN TELECOMMUNICATION NETWORKS) - PART 1: GENERIC INTERFACE
ES 202 336-3 : 1.1.1 ENVIRONMENTAL ENGINEERING (EE); MONITORING AND CONTROL INTERFACE FOR INFRASTRUCTURE EQUIPMENT (POWER, COOLING AND BUILDING ENVIRONMENT SYSTEMS USED IN TELECOMMUNICATION NETWORKS); PART 3: AC UPS POWER SYSTEM CONTROL AND MONITORING INFORMATION MODEL
ES 202 336-12 : 1.1.1 ENVIRONMENTAL ENGINEERING (EE); MONITORING AND CONTROL INTERFACE FOR INFRASTRUCTURE EQUIPMENT (POWER, COOLING AND BUILDING ENVIRONMENT SYSTEMS USED IN TELECOMMUNICATION NETWORKS); PART 12: ICT EQUIPMENT POWER, ENERGY AND ENVIRONMENTAL PARAMETERS MONITORING INFORMATION MODEL
ES 202 336-9 : 1.1.1 ENVIRONMENTAL ENGINEERING (EE); MONITORING AND CONTROL INTERFACE FOR INFRASTRUCTURE EQUIPMENT (POWER, COOLING AND BUILDING ENVIRONMENT SYSTEMS USED IN TELECOMMUNICATION NETWORKS); PART 9: ALTERNATIVE POWER SYSTEMS

EN 300 132-2 : 2.4.6 ENVIRONMENTAL ENGINEERING (EE); POWER SUPPLY INTERFACE AT THE INPUT TO TELECOMMUNICATIONS AND DATACOM (ICT) EQUIPMENT; PART 2: OPERATED BY -48 V DIRECT CURRENT (DC)
EN 300 132-3 : 1.2.1 ENVIRONMENTAL ENGINEERING (EE); POWER SUPPLY INTERFACE AT THE INPUT TO TELECOMMUNICATIONS EQUIPMENT; PART 3: OPERATED BY RECTIFIED CURRENT SOURCE, ALTERNATING CURRENT SOURCE OR DIRECT CURRENT SOURCE UP TO 400 V
ES 202 336-1 : 1.2.1 ENVIRONMENTAL ENGINEERING (EE); MONITORING AND CONTROL INTERFACE FOR INFRASTRUCTURE EQUIPMENT (POWER, COOLING AND BUILDING ENVIRONMENT SYSTEMS USED IN TELECOMMUNICATION NETWORKS) - PART 1: GENERIC INTERFACE
TR 102 336 : 1.1.1 ENVIRONMENTAL ENGINEERING (EE); POWER AND COOLING SYSTEM CONTROL AND MONITORING GUIDANCE
ISO 8879:1986 Information processing Text and office systems Standard Generalized Markup Language (SGML)
EN 302 099 : 2.1.1 ENVIRONMENTAL ENGINEERING (EE); POWERING OF EQUIPMENT IN ACCESS NETWORK

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.