AUTOMATIC EDDY-CURRENT TESTING OF TUBES - VERIFICATION OF HYDRAULIC LEAK TIGHTNESS OF STEEL TUBES

Superseded date

23-07-2013

Published date

12-01-2013

Sorry this product is not available in your region.

Specifies the procedures to be used for full peripheral eddy-current testing of seamless and welded steel tubes for verification of hydraulic leak tightness. Two different eddy-current testing methods, designated Method A and Method B, are specified, together with acceptance criteria reference standards and to establish the required level of test sensitivity. There is no restriction on tube diameter, with the exception that Method A is limited to a maximum tube diameter of 180 mm. It is intended that the Purchaser will specify in the relevant Product Specification which test method will be applied for tube diameters up to 180 mm.

DocumentType
Standard
PublisherName
Energy Networks Association (UK)
Status
Superseded
SupersededBy

ESI 23-4 : ISSUE 2 SEAMLESS STEEL FEED WATER HEATER TUBES FOR HIGH PRESSURE APPLICATIONS
ESI 68-1 : ISSUE 2 TUBES AND TUBE ASSEMBLIES FOR BOILERS

ESI 98-3 : ISSUE 1 REGISTRATION OF NON-DESTRUCTIVE TESTING PERSONNEL