ETSI EN 300 330-1 V1.8.1 (2015-03)
Current
The latest, up-to-date edition.
Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Part 1: Technical characteristics and test methods
Hardcopy , PDF
English
01-03-2015
Intellectual Property Rights
Foreword
Modal verbs terminology
Introduction
1 Scope
2 References
3 Definitions, symbols and abbreviations
4 Technical requirements specifications
5 Test conditions, power sources and ambient
temperatures
6 General conditions
7 Transmitter requirements
8 Receiver requirement
9 Measurement uncertainty
10 Interpretation of results
Annex A (normative) - Radiated measurement
Annex B (normative) - H-field limit correction factor
for generated E-fields
Annex C (normative) - Customized loop antennas
Annex D (informative) - Test fixture for measuring
inductive transmitter carrier and harmonic
currents by use of an artificial antenna
(Product Class 3 only)
Annex E (informative) - E-fields in the near field at
low frequencies
Annex F (normative) - H-field measurements and limits
at 3 m and 30 m
Annex G (normative) - Transmitter emission levels and
spectrum mask measurements
Annex H (normative) - Generic inductive loop limits in
the frequency range 148,5 kHz to 30 MHz
Annex I (informative) - Determination and use of the
measurement bandwidth
Annex J (informative) - Other limits
Annex K (informative) - Bibliography
History
Includes requirements for radiated emissions below as well as above 30 MHz.
| DocumentType |
Standard
|
| Pages |
68
|
| PublisherName |
European Telecommunications Standards Institute
|
| Status |
Current
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| DS EN 300330-1 : 2015 | Identical |
| NBN EN 300 330-1 : 2015 | Identical |
| PN EN 300 330-1 : 2015 | Identical |
| DIN EN 300330-1:2015-08 | Identical |
| NF EN 300330-1 : 2015 | Identical |
| NEN EN 300330-1 : 2015 | Identical |
| 10/30201740 DC : 0 | BS ISO/IEC 18046-2 - INFORMATION TECHNOLOGY - RADIO FREQUENCY IDENTIFICATION DEVICE PERFORMANCE TEST METHODS - PART 2: TEST METHODS FOR INTERROGATOR PERFORMANCE |
| BS ISO/IEC 18046-2:2011 | Information technology. Radio frequency identification device performance test methods Test methods for interrogator performance |
| ETSI EN 301 489-3 V1.6.1 (2013-08) | Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 3: Specific conditions for Short-Range Devices (SRD) operating on frequencies between 9 kHz and 246 GHz |
| 14/30295940 DC : 0 | BS ISO/IEC 18046-4 - INFORMATION TECHNOLOGY - RADIO FREQUENCY IDENTIFICATION DEVICE PERFORMANCE TEST METHODS - PART 4: TEST METHODS FOR PERFORMANCE OF RFID GATES IN LIBRARIES |
| BS ISO/IEC 18046-4:2015 | Information technology. Radio frequency identification device performance test methods Test methods for performance of RFID gates in libraries |
| VDI 4478 Blatt 1:2013-07 | Test procedure for standardizing the definition of performance of RFID gates for use in libraries |
| ISO/IEC 18046-2:2011 | Information technology — Radio frequency identification device performance test methods — Part 2: Test methods for interrogator performance |
| IEEE/ANSI C63.26-2015 | IEEE/ANSI Standard for Compliance Testing of Transmitters Used in Licensed Radio Services |
| ISO/IEC 18046-4:2015 | Information technology — Radio frequency identification device performance test methods — Part 4: Test methods for performance of RFID gates in libraries |
| ETSI EN 302 195-1 V1.1.1 (2004-03) | Electromagnetic compatibility and Radio spectrum Matters (ERM); Radio equipment in the frequency range 9 kHz to 315 kHz for Ultra Low Power Active Medical Implants (ULP-AMI) and accessories; Part 1: Technical characteristics and test methods |
| ETSI EN 300 330-2 V1.6.1 (2015-03) | Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Part 2: Harmonized EN covering the essential requirements of article 3.2 of the R&TTE Directive |
| ETSI EN 302 510-1 V1.1.1 (2007-07) | Electromagnetic compatibility and Radio spectrum Matters (ERM); Radio equipment in the frequency range 30 MHz to 37,5 MHz for Ultra Low Power Active Medical Membrane Implants and Accessories; Part 1: Technical characteristics and test methods |
| 2006/95/EC : 2006 | DIRECTIVE 2006/1995/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 12 DECEMBER 2006 ON THE HARMONISATION OF THE LAWS OF MEMBER STATES RELATING TO ELECTRICAL EQUIPMENT DESIGNED FOR USE WITHIN CERTAIN VOLTAGE LIMITS (CODIFIED VERSION) (TEXT WITH EEA RELEVANCE) |
| EN 62311:2008 | Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz) |
| CISPR 16-1-4:2010+AMD1:2012+AMD2:2017 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements |
| 1989/336/EEC : 1989 | COUNCIL DIRECTIVE OF 3 MAY 1989 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ELECTROMAGNETIC COMPATIBILITY |
| 2004/108/EC : 2004 | DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 15 DECEMBER 2004 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ELECTROMAGNETIC COMPATIBILITY AND REPEALING DIRECTIVE 89/336/EC |
| ETSI EN 301 489-3 V1.6.1 (2013-08) | Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 3: Specific conditions for Short-Range Devices (SRD) operating on frequencies between 9 kHz and 246 GHz |
| ETSI EN 300 328 V2.1.1 (2016-11) | Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz ISM band and using wide band modulation techniques; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU |
| EN 55022:2010/AC:2011 | INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008) |
| EN 62479:2010 | Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz) |
| ANSI C63.5 : 2006 | ELECTROMAGNETIC COMPATIBILITY - RADIATED EMISSION MEASUREMENTS IN ELECTROMAGNETIC INTERFERENCE (EMI) CONTROL - CALIBRATION AND QUALIFICATION OF ANTENNAS (9 KHZ TO 40 GHZ) |
| ETSI EN 301 489-17 V2.2.1 (2012-09) | ELECTROMAGNETIC COMPATIBILITY (EMC) STANDARD FOR RADIO EQUIPMENT AND SERVICES; PART 17: SPECIFIC CONDITIONS FOR BROADBAND DATA TRANSMISSION SYSTEMS; HARMONISED STANDARD COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.1(B) OF DIRECTIVE 2014/53/EU |
| 119999/5/EC : 1999 | DIRECTIVE 1999/5/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 9 MARCH 1999 ON RADIO EQUIPMENT AND TELECOMMUNICATIONS TERMINAL EQUIPMENT AND THE MUTUAL RECOGNITION OF THEIR CONFORMITY |
| ETSI TR 102 273-4 V1.2.1 (2001-12) | Electromagnetic compatibility and Radio spectrum Matters (ERM); Improvement on Radiated Methods of Measurement (using test site) and evaluation of the corresponding measurement uncertainties; Part 4: Open area test site |
| ETSI EN 300 330 V1.2.2 (1999-05) | ElectroMagnetic Compatibility and Radio Spectrum Matters (ERM); Short Range Devices (SRD); Technical characteristics and test methods for radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz |
| ETSI EN 301 489-1 V2.1.1 (2017-02) | ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements; Harmonised Standard covering the essential requirements of article 3.1(b) of Directive 2014/53/EU and the essential requirements of article 6 of Directive 2014/30/EU |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.