ETSI EN 300 385 V1.2.1 (1999-10)
Current
The latest, up-to-date edition.
Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for fixed radio links and ancillary equipment
Hardcopy , PDF
English
01-10-1999
Intellectual Property Rights
Foreword
1 Scope
2 References
3 Definitions and abbreviations
3.1 Definitions
3.2 Abbreviations
4 General test conditions
4.1 Test conditions and configurations
4.2 Exclusion bands
5 Performance assessment
5.1 General
5.2 Equipment which can provide a communications
link
5.3 Equipment which does not provide a communications
link
5.4 Ancillary equipment
6 Performance criteria for immunity tests
6.1 General performance criterion A (continuous
phenomena)
6.2 General performance criterion B (transient
phenomena)
6.3 General performance criterion C (interruptions)
6.4 Specific performance criteria
7 Applicability overview tables
7.1 Emission
7.2 Immunity
8 Test methods and limits for emission tests
8.1 Enclosure port
8.2 DC power input/output port
8.3 AC mains power input/output port
8.4 Antenna port
9 Test methods and levels for immunity tests
9.1 Radio frequency electromagnetic field
(80 MHz to 1 000 MHz)
9.2 Electrostatic discharge
9.3 Fast transients common mode
9.4 RF common mode, 0,15 MHz to 80 MHz
9.5 Voltage dips and interruptions
9.6 Surges common and differential mode
Annex A (normative): Clauses and/or subclauses of
the present document relevant for compliance
with the essential requirements of EC Council
Directives
Annex B (informative): Point to Multipoint fixed radio
links general system architecture
History
Revision of EN 300 385 to include: Specific fixed link standards prepared by TM4 Point to multipoint systems. Fixed link equipment with capacities below 2 Mbit/s. Analogue equipment Equipment operating at frequencies below 1 GHz.
| DocumentType |
Standard
|
| Pages |
31
|
| PublisherName |
European Telecommunications Standards Institute
|
| Status |
Current
|
| Standards | Relationship |
| NEN EN 300385 : 1999 | Identical |
| NF EN 300385 : 2001 | Identical |
| UNE-EN 300385 V1.2.1 | Identical |
| UNE-EN 300385 V1.2.1:2006 | Identical |
| NF EN 302063 : 2003 | FIXED RADIO SYSTEMS - MULTIPOINT EQUIPMENT - MULTIPOINT DIGITAL RADIO SYSTEMS OPERATING IN THE 31,0 GHZ TO 33,4 GHZ (32 GHZ) FREQUENCY RANGE |
| NF EN 301021 : 2004 | FIXED RADIO SYSTEMS - POINT-TO-MULTIPOINT EQUIPMENT - TIME DIVISION MULTIPLE ACCESS (TDMA) - POINT-TO-MULTIPOINT DIGITAL RADIO SYSTEMS IN FREQUENCY BANDS IN THE RANGE 3 GHZ TO 11 GHZ |
| NF EN 300408 : 2003 | TELECOMMUNICATIONS - FIXED RADIO SYSTEMS - POINT-TO-POINT EQUIPMENT - PARAMETERS FOR DIGITAL RADIO SYSTEMS FOR THE TRANSMISSION OF DIGITAL SIGNALS AND ANALOGUE VIDEO SIGNALS OPERATING AT AROUND 58 GHZ, WHICH DO NOT REQUIRE CO-ORDINATED FREQUENCY PLANNING |
| NF EN 301751 : 2003 | FIXED RADIO SYSTEMS - POINT-TO-POINT EQUIPMENTS AND ANTENNAS - GENERIC HARMONIZED STANDARD FOR POINT-TO-POINT DIGITAL FIXED RADIO SYSTEMS AND ANTENNAS COVERING THE ESSENTIAL REQUIREMENTS UNDER ARTICLE 3.2 OF THE 1999/5/EC DIRECTIVE |
| ETSI TR 102 937 V1.1.1 (2011-03) | eCall communications equipment; Conformance to EU vehicle regulations, R&TTE, EMC & LV Directives, and EU regulations for eCall implementation |
| NF EN 301997-1 : 2002 | TRANSMISSION AND MULTIPLEXING (TM) - MULTIPOINT EQUIPMENT - RADIO EQUIPMENT FOR USE IN MULTIMEDIA WIRELESS SYSTEMS (MWS) IN THE FREQUENCY BAND 40,5 GHZ TO 43,5 GHZ - PART 1: GENERAL REQUIREMENTS |
| NF EN 301127 : 2002 | FIXED RADIO SYSTEMS - POINT-TO-POINT EQUIPMENT - HIGH CAPACITY DIGITAL RADIO SYSTEMS CARRYING SDH SIGNALS (UP TO 2 X STM-1) IN FREQUENCY BANDS WITH ABOUT 30 MHZ CHANNEL SPACING AND USING CO-POLAR ARRANGEMENTS OR CO-CHANNEL DUAL POLARIZED (CCDP) OPERATION |
| NF EN 300198 : 2006 | FIXED RADIO SYSTEMS - POINT-TO-POINT EQUIPMENT - PARAMETERS FOR RADIO SYSTEMS FOR THE TRANSMISSION OF DIGITAL SIGNALS OPERATING AT 23 GHZ |
| ETSI EN 300 639 V1.3.1 (2001-02) | Fixed Radio Systems; Point-to-point equipment; Sub-STM-1 digital radio systems operating in the 13 GHz, 15 GHz and 18 GHz frequency bands with about 28 MHz co-polar and 14 MHz cross-polar channel spacing |
| ETSI EN 300 431 V1.4.1 (2002-07) | Fixed Radio Systems; Point-to-point equipment; Parameters for radio system for the transmission of digital signals operating in the frequency range 24,50 GHz to 29,50 GHz |
| EN 50081-1:1992 | Electromagnetic compatibility - Generic emission standard - Part 1: Residential, commercial and light industry |
| EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
| EN 61000-3-3:2013 | Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current |
| 1989/336/EEC : 1989 | COUNCIL DIRECTIVE OF 3 MAY 1989 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ELECTROMAGNETIC COMPATIBILITY |
| EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
| EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
| EN 55022:2010/AC:2011 | INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008) |
| EN 61000-3-2:2014 | Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) |
| EN 61000-4-4:2012 | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
| EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
| CISPR 16-1:1999+AMD1:2002 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1: Radio disturbance and immunity measuring apparatus |
| EN 50082-1:1997 | Electromagnetic compatibility - Generic immunity standard - Part 1: Residential, commercial and light industry |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.