• FM 4880 : 2017

    Current The latest, up-to-date edition.

    EVALUATING THE FIRE PERFORMANCE OF INSULATED BUILDING PANEL ASSEMBLIES AND INTERIOR FINISH MATERIALS

    Available format(s): 

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Factory Mutual Research Corporation

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 INTRODUCTION
    2 GENERAL INFORMATION
    3 APPLICABLE DOCUMENTS AND GLOSSARY
    4 GENERAL REQUIREMENTS
    5 PERFORMANCE REQUIREMENTS
    APPENDIX A - PERFORMANCE REQUIREMENTS BASED ON PRODUCT
                 TYPE AND DESIRED RATINGS
    APPENDIX B - CONVERSION OF MEASUREMENT UNITS
    APPENDIX C - ROOM TEST
    APPENDIX D - 16 FT (4.9 M) HIGH PARALLEL PANEL TEST
    APPENDIX E - 25 FT (7.6 M) HIGH CORNER TEST
    APPENDIX F - 50 FT (15.2 M) HIGH CORNER TEST

    Abstract - (Show below) - (Hide below)

    Describes to the fire performance requirements for a Class 1 fire rating of building panels or interior finish materials.

    General Product Information - (Show below) - (Hide below)

    Development Note 2015 Edition is still active. (02/2017)
    Document Type Standard
    Publisher Factory Mutual Research Corporation
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    NFPA 275 : 2017 STANDARD METHOD OF FIRE TESTS FOR THE EVALUATION OF THERMAL BARRIERS
    NFPA 5000 : 2018 BUILDING CONSTRUCTION AND SAFETY CODE
    ICC 2009 INT. RESI.CODE & COMM.-I1 : 2009 2009 INTERNATIONAL RESIDENTIAL CODE & COMMENTARY - VOLUME 2: CHAPTERS 12 TO 44
    FM 4472 : 2016 CEMENTITIOUS PANEL ROOF DECKS
    FM 4451 : 2012 PROFILED STEEL PANELS FOR USE AS DECKING IN CLASS 1 INSULATED ROOF CONSTRUCTION
    FM 4431 : 2006 SKYLIGHTS
    ICC IRC Code and Commentary Volume 1 : 2015 IRC® Code and Commentary, Volume 1
    ICC 2012 INTERNATIONAL BUILDING CODE : 2012 INTERNATIONAL BUILDING CODE
    NFPA 1 : 2021 FIRE CODE
    FM 4350 : 2006 WINDSTORM RESISTANT FENESTRATIONS
    FM 4881 : 2017 EVALUATING EXTERIOR WALL SYSTEMS
    FM 4411 : 2016 CAVITY WALLS AND RAINSCREENS
    NFPA 101 : 2018 LIFE SAFETY CODE
    ICC IRC CODE AND COMMENTARY VOLUME 2 : 2015 IRC® Code and Commentary, Volume 2
    ICC IBC CODE AND COMMENTARY VOLUME 2 : 2015 IBC® Code and Commentary, Volume 2
    ASTM E 603 : 2017 : REDLINE Standard Guide for Room Fire Experiments
    ICC 2012 INTERNATIONAL RESI. CODE : 2012 INTERNATIONAL RESIDENTIAL CODE FOR ONE- AND TWO-FAMILY DWELLINGS
    FM 4882 : 2016 CLASS 1 INTERIOR WALL AND CEILING MATERIALS OR SYSTEMS FOR SMOKE SENSITIVE OCCUPANCIES
    FM 4471 : 2010 CLASS 1 PANEL ROOFS
    ASCE/SEI 30 14 : 2014 GUIDELINE FOR CONDITION ASSESSMENT OF THE BUILDING ENVELOPE
    NFPA 1 : 2018 FIRE CODE

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 9705:1993 Fire tests Full-scale room test for surface products
    ISO 1716:2010 Reaction to fire tests for products Determination of the gross heat of combustion (calorific value)
    ASTM D 792 : 2013 : REDLINE Standard Test Methods for Density and Specific Gravity (Relative Density) of Plastics by Displacement
    IEEE/ASTM SI_10-2010 American National Standard for Metric Practice
    NFPA 265 : 2015 METHODS OF FIRE TESTS FOR EVALUATING ROOM FIRE GROWTH CONTRIBUTION OF TEXTILE OR EXPANDED VINYL WALL COVERINGS ON FULL HEIGHT PANELS AND WALLS
    NFPA 286 : 2015 STANDARD METHODS OF FIRE TESTS FOR EVALUATING CONTRIBUTION OF WALL AND CEILING INTERIOR FINISH TO ROOM FIRE GROWTH
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective