• HD 22.16 : 200S2

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 16: WATER RESISTANT POLYCHLOROPRENE OR EQUIVALENT SYNTHETIC ELASTOMER SHEATHED CABLES

    Available format(s): 

    Superseded date:  01-05-2011

    Language(s): 

    Published date:  12-01-2013

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Scope
    2 Normative references
    3 Water-resistant polychloroprene or other equivalent
      synthetic elastomer sheathed flexible cable
    4 Water-resistant polychloroprene or other equivalent
      synthetic elastomer sheathed flexible cable with more
      than five conductors (Multicore cables)
    Annex A (normative) Requirements for compatibility test
    Annex B (normative) Water resistance test for H07RN8-F
            flexible cables - Electrical test
    Annex C (normative) Water resistance test for H07RN8-F
            flexible cables - Mechanical properties of sheath
            after water immersion
    Bibliography

    Abstract - (Show below) - (Hide below)

    Provides the particular specifications for water resistant EPR insulated, polychloroprene or other equivalent synthetic elastomer sheathed flexible cables of rated voltages up to and including 450/750 V.

    General Product Information - (Show below) - (Hide below)

    Committee TC 20
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    CLC/TR 50424:2004 Electric cables - List of residual recognised national types
    NF EN 15869-2 : 2010 INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 2: ONSHORE UNIT, SAFETY REQUIREMENTS
    03/320456 DC : DRAFT JAN 2004 CLC/PRTR 50424 - LIST OF RESIDUAL RECOGNISED NATIONAL TYPES
    DIN EN 15869-3:2010-06 INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 3: ON-BOARD UNIT, SAFETY REQUIREMENTS
    UNE-EN 15869-2:2011 Inland navigation vessels - Electrical shore connection, three phase current 400 V, up to 63 A, 50 Hz - Part 2: Onshore unit, safety requirements
    DIN EN 15869-2:2010-06 INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 2: ONSHORE UNIT, SAFETY REQUIREMENTS
    BS EN 15869-3:2010 INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 3: ON-BOARD UNIT, SAFETY REQUIREMENTS
    BS 7919:2001 ELECTRIC CABLES - FLEXIBLE CABLES RATED UP TO 450/750 V, FOR USE WITH APPLIANCES AND EQUIPMENT INTENDED FOR INDUSTRIAL AND SIMILAR ENVIRONMENTS
    I.S. EN 15869-3:2010 INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 3: ON-BOARD UNIT, SAFETY REQUIREMENTS
    PD CLC/TR 50424:2004 ELECTRIC CABLES - LIST OF RESIDUAL RECOGNISED NATIONAL TYPES
    I.S. EN 15869-2:2010 INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 2: ONSHORE UNIT, SAFETY REQUIREMENTS
    BS EN 15869-2:2010 INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 2: ONSHORE UNIT, SAFETY REQUIREMENTS
    EN 15869-2:2010 Inland navigation vessels - Electrical shore connection, three phase current 400 V, up to 63 A, 50 Hz - Part 2: Onshore unit, safety requirements
    EN 15869-3:2010 Inland navigation vessels - Electrical shore connection, three phase current 400 V, up to 63 A, 50 Hz - Part 3: On-board unit, safety requirements
    S.R. CLC/TR 50424:2004 ELECTRIC CABLES - LIST OF RESIDUAL RECOGNISED NATIONAL TYPES
    I.S. HD 384.7.702:2002 ELECTRICAL INSTALLATIONS OF BUILDINGS - REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - SWIMMING POOLS AND OTHER BASINS
    NF EN 15869-3 : 2010 INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION THREE PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 3: ON-BOARD UNIT, SAFETY REQUIREMENTS
    UNI EN 15869-3 : 2010 INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE-PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 3: ON-BOARD UNIT, SAFETY REQUIREMENTS
    HD 384.7.702 : 200S2 ELECTRICAL INSTALLATIONS OF BUILDINGS - REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - SWIMMING POOLS AND OTHER BASINS

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 60719:1993 Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V
    IEC 60228:2004 Conductors of insulated cables
    IEC 60502-1:2004+AMD1:2009 CSV Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV(Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV)
    EN 60228:2005 COR 2005 CONDUCTORS OF INSULATED CABLES
    EN 60332-1-2:2004/A11:2016 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004/A1:2015)
    IEC 60332-1-2:2004+AMD1:2015 CSV Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame
    IEC 60719:1992 Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V
    HD 516 S2:1997/A2:2008 GUIDE TO USE OF LOW VOLTAGE HARMONIZED CABLES
    EN 50395 : 2005 AMD 1 2011 ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
    EN 50363-1:2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 1: Cross-linked elastomeric insulating compounds
    HD 384.3 : 200S2 ELECTRICAL INSTALLATIONS OF BUILDINGS - ASSESSMENT OF GENERAL CHARACTERISTICS
    EN 50334:2001 Marking by inscription for the identification of cores of electric cables
    EN 50363-2-1 : 2005 AMD 1 2011 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 2-1: CROSS-LINKED ELASTOMERIC SHEATHING COMPOUNDS
    EN 50396 : 2005 AMD 1 2011 NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective