HD 60364-4-443:2016

Current

Current

The latest, up-to-date edition.

Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances - Clause 443: Protection against transient overvoltages of atmospheric origin or due to switching

Published date

19-02-2016

Sorry this product is not available in your region.
Summarise this standard

FOREWORD
INTRODUCTION
440.1 Scope
440.2 Normative references
441 (Vacant)
442 Protection of low-voltage installations against
    temporary overvoltages due to earth faults in the
    high-voltage system and due to faults in the low-
    voltage system
443 Protection against transient overvoltages of
     atmospheric origin or due to switching
444 Measures against electromagnetic influences
445 Protection against undervoltage
Annex A (informative) - Examples of calculated
        risk level CRL for the use of SPDs
Annex B (informative) - Guidance on overvoltage
        control by SPDs applied to overhead lines
Bibliography
Annex ZA (normative) - Special national conditions
Annex ZB (informative) - A-deviations

The rules of IEC 60364-4-44 are intended to provide requirements for the safety of electrical installations in the event of voltage disturbances and electromagnetic disturbances generated for different specified reasons.The rules of this IEC 60364-4-44 are not intended to apply to systems for distribution of energy to the public, or power generation and transmission for such systems (see the scope of IEC 60364-1) although such disturbances may be conducted into or between electrical installations via these supply systems.Clause 443 specifies requirements for protection of electrical installations against transient overvoltages of atmospheric origin transmitted by the supply distribution system including direct strikes to the supply system and against switching overvoltages. Clause 443 does not specify requirements for protection against transient overvoltage due to direct or nearby lightning strokes on the structure.NOTEFor risk management for protection against transient overvoltage due to direct or nearby lightning strokes on the structure, see IEC 62305-2.