HD 607 : 200S1
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
BUSBAR BUSHINGS UP TO 1 KV AND FROM 1,25 KA TO 5 KA, FOR LIQUID FILLED TRANSFORMERS
01-11-2002
12-01-2013
Committees responsible
National foreword
Foreword
Introduction
1 Scope
2 Definitions
2.1 Moulded indoor busbar bushing
3 Requirements
3.1 Application
3.2 Standard value of rated voltage (Ur)
3.3 Standard values of rated current (Ir)
3.4 Minimum nominal creepage distance
3.5 Dielectric characteristics
3.6 Dimensions
Deals with moulded indoor busbar bushings with rated currents from 1250A up to 5000A, frequencies from 15Hz up to 60Hz, and rated voltages not exceeding 1000V, for insulating liquid filled transformers.
Committee |
CENELEC TC 36A
|
DocumentType |
Standard
|
PublisherName |
Harmonization Documents
|
Status |
Superseded
|
Standards | Relationship |
DIN 42543:1997-03 | Identical |
DIN 42543:1997-03 | Corresponds |
BS 7877:1999 | Identical |
SN HD 607 : 200S1 | Identical |
NEN HD 607 : 1996 | Identical |
CEI 36-17 : 1ED 1998 | Identical |
UNE 21607:1997 | Similar to |
NFC 66 522 : 1996 | Identical |
BS 7821-2.2:1998 | Three phase oil-immersed distribution transformers, 50 Hz, from 50 to 2500 kVA with highest voltage for equipment not exceeding 36 kV. Distribution transformers with cable boxes on the high voltage and/or low voltage side Cable boxes of type 1 for use on distribution transformers meeting the requirements of BS 7821-2.1 |
I.S. HD 428-2-2:1999 | THREE-PHASE OIL-IMMERSED DISTRIBUTION TRANSFORMERS 50 HZ, FROM 50 TO 2500 KVA WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 2: DISTRIBUTION TRANSFORMERS WITH CABLE BOXES ON THE HIGH-VOLTAGE AND/OR LOW VOLTAGE SIDE - SECTION 2: CABLE BOXES TYPE 1 FOR USE ON DISTRIBUTION TRANSFORMERS MEETING THE REQUIREMENTS OF HD 428.2.1 S1 |
HD 428.2.2 : 200S1 | THREE-PHASE OIL-IMMERSED DISTRIBUTION TRANSFORMERS 50 HZ, FROM 50 TO 2500 KVA WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 2: DISTRIBUTION TRANSFORMERS WITH CABLE BOXES ON THE HIGH-VOLTAGE AND/OR LOW VOLTAGE SIDE - SECTION 2: CABLE BOXES TYPE 1 FOR USE ON DISTRIBUTION TRANSFORMERS MEETING THE REQUIREMENTS OF HD 428.2.1 S1 |