    1 Scope
    2 Definitions
          2.1 Moulded indoor busbar bushing
    3 Requirements
          3.1 Application
          3.2 Standard value of rated voltage (Ur)
          3.3 Standard values of rated current (Ir)
          3.4 Minimum nominal creepage distance
          3.5 Dielectric characteristics
          3.6 Dimensions

    Abstract - (Show below) - (Hide below)

    Deals with moulded indoor busbar bushings with rated currents from 1250A up to 5000A, frequencies from 15Hz up to 60Hz, and rated voltages not exceeding 1000V, for insulating liquid filled transformers.

    General Product Information - (Show below) - (Hide below)

    Committee CENELEC TC 36A
    Document Type Standard
    Publisher Harmonization Documents
    Status Superseded

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS 7821-2.2:1998 Three phase oil-immersed distribution transformers, 50 Hz, from 50 to 2500 kVA with highest voltage for equipment not exceeding 36 kV. Distribution transformers with cable boxes on the high voltage and/or low voltage side Cable boxes of type 1 for use on distribution transformers meeting the requirements of BS 7821-2.1
    I.S. HD 428-2-2:1999 THREE-PHASE OIL-IMMERSED DISTRIBUTION TRANSFORMERS 50 HZ, FROM 50 TO 2500 KVA WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 2: DISTRIBUTION TRANSFORMERS WITH CABLE BOXES ON THE HIGH-VOLTAGE AND/OR LOW VOLTAGE SIDE - SECTION 2: CABLE BOXES TYPE 1 FOR USE ON DISTRIBUTION TRANSFORMERS MEETING THE REQUIREMENTS OF HD 428.2.1 S1
    HD 428.2.2 : 200S1 THREE-PHASE OIL-IMMERSED DISTRIBUTION TRANSFORMERS 50 HZ, FROM 50 TO 2500 KVA WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 2: DISTRIBUTION TRANSFORMERS WITH CABLE BOXES ON THE HIGH-VOLTAGE AND/OR LOW VOLTAGE SIDE - SECTION 2: CABLE BOXES TYPE 1 FOR USE ON DISTRIBUTION TRANSFORMERS MEETING THE REQUIREMENTS OF HD 428.2.1 S1