I.S. EN 15655:2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
DUCTILE IRON PIPES, FITTINGS AND ACCESSORIES - INTERNAL POLYURETHANE LINING FOR PIPES AND FITTINGS - REQUIREMENTS AND TEST METHODS
Hardcopy , PDF
English
01-01-2009
17-12-2020
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Ordering information
5 Technical Requirements
5.1 Surface preparation
5.2 Finished polyurethane lining
5.3 Pipe ends
5.4 Repairs
5.5 Marking
5.6 Non porosity
5.7 Hardness
5.8 Adhesion
6 Performance Requirements
6.1 Chemical resistance
6.2 Indirect Impact strength
6.3 Resistance to ovalization
6.4 Elongation at break
6.5 Specific lining resistance
6.6 Abrasion resistance (only for waste
water application)
6.7 Light ageing
6.8 Materials in contact with water intended
for human consumption
7 Test Methods
7.1 Routine tests
7.2 Performance tests
Annex A (informative) - Quality assurance
A.1 General
A.2 Performance test; DN grouping
A.3 Quality assessment system
Annex B (informative) - Lining process and materials
B.1 Lining application process
B.2 Material properties
B.3 Field of use, characteristics of transported
waters
Annex C (informative) - Packaging
Bibliography
Describes the requirements and test methods applicable to factory applied internal polyurethane high duty corrosion protection of buried ductile iron pipes and fittings conforming to EN 545, EN 598 and EN 969 for use at permanent operating temperatures up to 45 Degrees C.
| DocumentType |
Standard
|
| Pages |
24
|
| PublisherName |
National Standards Authority of Ireland
|
| Status |
Superseded
|
| SupersededBy |
| Standards | Relationship |
| EN 15655:2009 | Identical |
| DIN EN 15655:2009-06 | Equivalent |
| BS EN 15655:2009 | Equivalent |
| UNE-EN 15655:2009 | Equivalent |