DISTRICT HEATING PIPES - PREINSULATED BONDED PIPE SYSTEMS FOR DIRECTLY BURIED HOT WATER NETWORKS - PIPE ASSEMBLY OF STEEL SERVICE PIPE, POLYURETHANE THERMAL INSULATION AND OUTER CASING OF POLYETHYLENE

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-2009

Withdrawn date

30-04-2020

Superseded by

I.S. EN 253:2019

€80.00
Excluding VAT
Summarise this standard

For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.

Only cited Standards give presumption of conformance to New Approach Directives/Regulations.


Dates of withdrawal of national standards are available from NSAI.

National Foreword
European foreword
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Test methods
6 Marking
Annex A (informative) - Relation between actual
        continuous operating conditions and
        accelerated ageing test conditions
Annex B (informative) - Calculation of the minimum
        expected thermal life with operation at
        various temperatures with respect to PUR
        foam performance
Annex C (normative) - Calculated Continuous Operating
        Temperature (CCOT)
Annex D (informative) - Guidelines for inspection
        and testing
Annex E (informative) - Radial creep behaviour of the
        polyurethane foam (PUR)
Annex F (normative) - Thermal conductivity of
        pre-insulated pipes - Test procedure
Annex G (informative) - National A-deviations
Annex H (informative) - Main changes from the previous
        edition of EN 253
Annex I (informative) - Waste treatment and recycling
Bibliography

Defines requirements and test methods for straight lengths of prefabricated thermally insulated pipe-in-pipe assemblies for directly buried hot water networks, comprising a steel service pipe from DN 15 to DN 1200, rigid polyurethane foam insulation and an outer casing of polyethylene.

DevelopmentNote
2009 Edition Re-Issued in November 2015 & incorporates AMD 2 2015. (11/2015)
DocumentType
Standard
Pages
58
PublisherName
National Standards Authority of Ireland
Status
Withdrawn
SupersededBy
Supersedes

Standards Relationship
BS EN 253 : 2009 Identical
NF EN 253 : 2009 + A2 2015 Identical
NS EN 253 : 2009 + A2 2015 Identical
NBN EN 253 : 2009 + A2 2015 Identical
DIN EN 253:2015-12 Identical
EN 253:2009+A2:2015 Identical
NEN EN 253 : 2009 + A2 2015 Identical
EN 253:2009 Equivalent
UNE-EN 253:2010 Identical

⚠

A newer version of this standard is available.

€80.00
Excluding VAT