I.S. EN 402:2003
Current
The latest, up-to-date edition.
RESPIRATORY PROTECTIVE DEVICES - LUNG GOVERNED DEMAND SELF-CONTAINED OPEN-CIRCUIT COMPRESSED AIR BREATHING APPARATUS WITH FULL FACE MASK OR MOUTHPIECE ASSEMBLY FOR ESCAPE - REQUIREMENTS, TESTING, MARKING
Hardcopy , PDF
English
01-01-2003
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
Foreword
Introduction
1 Scope
2 Normative references
3 Definition and description
4 Description
5 Classification
6 Requirements
6.1 General
6.2 Ergonomics
6.3 Design
6.4 Materials
6.5 Cleaning and disinfecting
6.6 Mass
6.7 Connections
6.8 Harness
6.9 Handling
6.10 Leak tightness
6.11 Facepiece
6.12 Goggles
6.13 Temperature performance and flammability resistance
6.14 Protection against particulate matter
6.15 High and medium pressure parts
6.16 High, medium and low pressure connections
6.17 Pressure vessel(s)
6.18 Pressure vessel seal
6.19 Pressure reducer
6.20 Pressure safety valve
6.21 Pressure indicator
6.22 Flexible hoses and tubes
6.23 Mechanical strength
6.24 Performance requirements
6.25 Protection against environment
6.26 Practical performance
7 Testing
7.1 General
7.2 Nominal values and tolerances
7.3 Visual inspection
7.4 Mechanical strength
7.5 Resistance to temperature
7.6 Pressure reducer
7.7 Low temperature practical performance
7.8 Practical performance
7.9 Breathing resistance
8 Marking
9 Information supplied by the manufacturer
Annex A (normative) - Methods of measurement of the insulation
resistance of the carrying container
Annex B (informative) - Test results - Uncertainty of measurement
Annex C (informative) - Marking
Annex ZA (informative) - Clauses of this European standard addressing
essential requirements or other provisions
of EU Directives
Bibliography
Provides minimum requirements for lung governed demand self-contained open-circuit compressed air breathing apparatus for escape.
DocumentType |
Standard
|
Pages |
33
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NF EN 402 : 2003 | Identical |
NBN EN 402 : 2003 | Identical |
EN 402:2003 | Identical |
NEN EN 402 : 2003 | Identical |
UNI EN 402 : 2004 | Identical |
NS EN 402 : 2ED 2003 | Identical |
UNE-EN 402:2004 | Identical |
BS EN 402:2003 | Identical |
SN EN 402 : 2003 | Identical |
DIN EN 402:2003-09 | Identical |
EN 148-3:1999 | Respiratory protective devices - Threads for facepieces - Part 3: Tread connection M 45 x 3 |
EN 12021:2014 | Respiratory equipment - Compressed gases for breathing apparatus |
EN 168:2001 | Personal eye-protection - Non-optical test methods |
EN 132:1998 | Respiratory protective devices - Definitions of terms and pictograms |
EN 13274-3:2001 | Respiratory protective devices - Methods of test - Part 3: Determination of breathing resistance |
EN 134:1998 | Respiratory protective devices - Nomenclature of components |
EN 13274-4:2001 | Respiratory protective devices - Methods of test - Part 4: Flame tests |
EN 13274-6:2001 | Respiratory protective devices - Methods of test - Part 6: Determination of carbon dioxide content of the inhalation air |
EN 13274-1:2001 | Respiratory protective devices - Methods of test - Part 1: Determination of inward leakage and total inward leakage |
EN 166:2001 | Personal eye-protection - Specifications |
EN 13274-2:2001 | Respiratory protective devices - Methods of test - Part 2: Practical performance tests |
EN 13274-5:2001 | Respiratory protective devices - Methods of test - Part 5: Climatic conditions |
EN 142:2002 | Respiratory protective devices - Mouthpiece assemblies - Requirements, testing, marking |
Access your standards online with a subscription