I.S. EN 50164-2:2008
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
LIGHTNING PROTECTION COMPONENTS (LPC) - PART 2: REQUIREMENTS FOR CONDUCTORS AND EARTH ELECTRODES
Hardcopy , PDF
07-06-2012
English
01-01-2008
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
1 Scope
2 Normative references
3 Definitions
4 Requirements
4.1 Documentation
4.2 Air termination conductors, air termination rods and down
conductors
4.3 Earth electrodes
5 Tests
5.1 General conditions for tests
5.2 Air termination conductors, air termination rods, earth
lead-in rods, down conductors and earth conductors
5.3 Earth rods
5.4 Joints for earth rods
6 Electromagnetic compatibility (EMC)
7 Structure and content of the test report
7.1 Report identification
7.2 Specimen description
7.3 Conductor
7.4 Standards and references
7.5 Test procedure
7.6 Testing equipment, description
7.7 Measuring instruments description
7.8 Results and parameters recorded
7.9 Statement of pass/fail
Annex A (normative) Environmental test for conductors, air
termination rods, earth rods and earth lead-in rods
Annex B (normative) Requirements for minimum cross sectional
area, mechanical and electrical characteristics, tests
to be applied
Annex C (normative) Requirements for minimum dimensions,
mechanical and electrical characteristics, tests to
be applied
Annex D (informative) Typical example calculation of conductor
resistivity
Describes the requirements and tests for metallic conductors (other than "natural" conductors) that form part of the air termination system and down conductors; and metallic earth electrodes that form part of the earth termination system.
DocumentType |
Standard
|
Pages |
28
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NEN EN 50164-2 : 2008 | Identical |
SN EN 50164-2 : 2008 | Identical |
UNE-EN 50164-2:2009 | Identical |
NBN EN 50164-2 : 2010 | Identical |
NF EN 50164-2 : 2008 | Identical |
BS EN 50164-2:2008 | Identical |
DIN EN 50164-2 : 2009 | Identical |
EN 50164-2:2008 | Identical |
EN 10002-1 : 2001 | METALLIC MATERIALS - TENSILE TESTING - PART 1: METHOD OF TEST AT AMBIENT TEMPERATURE |
EN 62305-4:2011/AC:2016 | PROTECTION AGAINST LIGHTNING - PART 4: ELECTRICAL AND ELECTRONIC SYSTEMS WITHIN STRUCTURES (IEC 62305-4:2010) |
EN ISO 1461:2009 | Hot dip galvanized coatings on fabricated iron and steel articles - Specifications and test methods (ISO 1461:2009) |
ISO 1461:2009 | Hot dip galvanized coatings on fabricated iron and steel articles — Specifications and test methods |
EN 62305-4:2011/AC:2016-11 | Protection against lightning - Part 4: Electrical and electronic systems within structures |
IEC 62305-1:2010 | Protection against lightning - Part 1: General principles |
EN ISO 6988:1994 | Metallic and other non-organic coatings - Sulfur dioxide test with general condensation of moisture (ISO 6988:1985) |
EN 62305-3:2011 | Protection against lightning - Part 3: Physical damage to structures and life hazard |
EN ISO 1460:1994 | Metallic coatings - Hot dip galvanized coatings on ferrous materials - Gravimetric determination of the mass per unit area (ISO 1460:1992) |
IEC TR 60648:1979 | Method of test for coefficients of friction of plastic film and sheeting for use as electrical insulation |
ISO 2178:2016 | Non-magnetic coatings on magnetic substrates Measurement of coating thickness Magnetic method |
EN 50164-1:2008 | Lightning Protection Components (LPC) - Part 1: Requirements for connection components |
IEC 62305-4:2010 | Protection against lightning - Part 4: Electrical and electronic systems within structures |
ISO 1460:1992 | Metallic coatings Hot dip galvanized coatings on ferrous materials Gravimetric determination of the mass per unit area |
ISO 6988:1985 | Metallic and other non organic coatings Sulfur dioxide test with general condensation of moisture |
IEC 60068-2-52:2017 | Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |
IEC 62305-3:2010 | Protection against lightning - Part 3: Physical damage to structures and life hazard |
EN ISO 2178:2016 | Non-magnetic coatings on magnetic substrates - Measurement of coating thickness - Magnetic method (ISO 2178:2016) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.