    INDUSTRIAL COMMUNICATIONS SUBSYSTEM BASED ON ISO 11898 (CAN) FOR CONTROLLER-DEVICE INTERFACES - SMART DISTRIBUTED SYSTEM (SDS)

    Available format(s):  Hardcopy, PDF

    Withdrawn date:  09-06-2016

    Language(s):  English

    Published date:  22-06-2001

    Publisher:  National Standards Authority of Ireland

    For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
    Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

    Dates of withdrawal of national standards are available from NSAI.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Introduction
    General information on licensing
    1 Scope
    2 Normative references
    3 Definitions, abbreviations and symbols
      3.1 Definitions
           3.1.1 Application Layer
           3.1.2 Application Layer Protocol (ALP)
           3.1.3 Application Layer Protocol Data Unit (APDU)
           3.1.4 Application Layer Service
           3.1.5 Autobaud
           3.1.6 Change Of State (COS)
           3.1.7 Change Of Value (COV)
           3.1.8 Confirm
           3.1.9 Data Link Layer Protocol Data Unit (DLPDU)
           3.1.10 Embedded Object
           3.1.11 Embedded Object Identifier
           3.1.12 Indication
           3.1.13 Logical Device
           3.1.14 Network
           3.1.15 Object Model
           3.1.16 Physical component
           3.1.17 Physical Layer Interface PLI
           3.1.18 Primitive
      3.2 Abbreviations
      3.3 Symbols
           3.3.1 (+)
           3.3.2 (-)
           3.3.3 (=)
    4 Relationship with the OSI Reference Model
    5 Characteristics
      5.1 SDS Network
           5.1.1 Network
           5.1.2 Modelling
           5.1.3 Hierarchy
      5.2 SDS Application Layer Services
           5.2.1 Service conventions
           5.2.2 Read service
           5.2.3 Write service
           5.2.4 Event service
           5.2.5 Action service
           5.2.6 Change Of State ON (COS ON) service
           5.2.7 Change Of State OFF (COS OFF) service
           5.2.8 Write State ON (WRITE ON) service
           5.2.9 Write State OFF (WRITE OFF) service
      5.3 SDS Application Layer Protocol
           5.3.1 Application Protocol Data Unit (APDU)
           5.3.2 APDU Forms
           5.3.3 Error Codes
           5.3.4 Data types
      5.4 SDS APDUs embedded in CAN frames
      5.5 Example Short Form APDUs
      5.6 Example Long Form APDUs
    6 Product information
      6.1 Instructions for installation, operation and
           maintenance
      6.2 Marking
    7 Normal service, transport and mounting con
    8 Construction and performance requirements
      8.1 SDS Physical Layer Interface (PLI)
           8.1.1 SDS power PLI
           8.1.2 Transceivers
           8.1.3 Transceivers specifications
           8.1.4 Indicating means
      8.2 SDS Network
           8.2.1 Topology
           8.2.2 SDS power distribution
           8.2.3 Auxiliary power ground connection
      8.3 Electromagnetic Compatibility (EMC)
           8.3.1 General requirements for electromagnetic
                  compatibility tests
           8.3.2 General test conditions for electromagnetic
                  compatibility tests
           8.3.3 Immunity requirements
           8.3.4 Emission requirements
    9 SDS Communication channel type tests
      9.1 General
      9.2 Product Model
      9.3 Object Model test
           9.3.1 General
           9.3.2 Attributes
           9.3.3 Actions
           9.3.4 Events
           9.3.5 Short form services COS ON and COS OFF
           9.3.6 Short form services WRITE ON and WRITE OFF
      9.4 Physical Layer Test
           9.4.1 Transceiver functional test
           9.4.2 Transceiver Input Resistance
           9.4.3 Transceiver input levels
           9.4.4 Transceiver output levels
           9.4.5 SDS power
      9.5 Application Layer Test
           9.5.1 ALP Services
           9.5.2 Logical Device functions
           9.5.3 Network functions
      9.6 System test
           9.6.1 System test set-up
           9.6.2 Non-participative system testing
           9.6.3 Participative system testing
           9.6.4 Other basic system testing
      9.7 Electromagnetic Compatibility Test
           9.7.1 General
           9.7.2 Fast transient/burst immunity

    Abstract - (Show below) - (Hide below)

    Covers the following particular requirements for Smart Distributed System (SDS): - Requirements for interfaces between control devices and switching elements; - Normal service conditions for devices; - Constructional and performance requirements; - Tests to verify conformance to requirements.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher National Standards Authority of Ireland
    Status Withdrawn
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective