• I.S. EN 50329:2007

    Current The latest, up-to-date edition.

    RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  01-01-2007

    Publisher:  National Standards Authority of Ireland

    For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
    Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

    Dates of withdrawal of national standards are available from NSAI.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Introduction
    1 General
    2 General requirements for a traction transformer
    3 Directly-coupled traction transformer
    4 Traction converter transformers
    5 Auxiliary transformers
    6 Traction auto-transformers
    Annex A (informative) - Preferred duty classes
    Annex B (normative) - Insulation characteristics and test
            values
    Annex C (normative) - Determination of losses and of
            equivalent current by means of alternative methods
    Annex E (informative) - Evaluation of traction transformer
            behaviour
    Annex F (informative) - Information for tenders and orders
    Bibliography

    Abstract - (Show below) - (Hide below)

    Specifies specific characteristics of traction transformers, used in traction substation or along the track for the supply of power to a.c. and d.c. traction systems or to provide power to auxiliary services.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes I.S. HD 591. (07/2005) 2003 Edition Re-Issued in June 2010 & incorporates AMD 1 2010. (06/2010) Partially Supersedes 1993 edition of I.S. EN 60146-1-3. (07/2017)
    Document Type Standard
    Publisher National Standards Authority of Ireland
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    HD 428.4 : 200S1 THREE-PHASE OIL-IMMERSED DISTRIBUTION TRANSFORMERS 50 HZ, FROM 50 TO 2500 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - DETERMINATION OF THE POWER RATING OF A TRANSFORMER LOADED WITH NON-SINUSODIAL CURRENTS
    IEC 60076-7:2005 Power transformers - Part 7: Loading guide for oil-immersed power transformers
    R009-002 : 1998 RAILWAY APPLICATIONS - GUIDE FOR THE USE OF THE TERMINOLOGY FOR TESTING PROCEDURES
    EN 50122-1:2011/A4:2017 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRICAL SAFETY, EARTHING AND THE RETURN CIRCUIT - PART 1: PROTECTIVE PROVISIONS AGAINST ELECTRIC SHOCK
    EN 61000-2-12:2003 Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems
    EN 60076-5:2006 Power transformers - Part 5: Ability to withstand short-circuit
    EN 60076-11:2004 Power transformers - Part 11: Dry-type transformers
    IEC 60076-5:2006 Power transformers - Part 5: Ability to withstand short circuit
    HD 538.3 : 200S1 THREE-PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 TO 2500 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 3: DETERMINATION OF THE POWER RATING OF A TRANSFORMER LOADED WITH NON-SINUSOIDAL CURRENT
    EN 50124-1:2017 Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment
    EN 50125-2:2002/corrigendum:2010 RAILWAY APPLICATIONS - ENVIRONMENTAL CONDITIONS FOR EQUIPMENT - PART 2: FIXED ELECTRICAL INSTALLATIONS
    IEC 60076-3:2013 Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air
    EN 50327 : 2003 AMD 1 2005 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS
    IEC 60076-1:2011 Power transformers - Part 1: General
    EN 50152-1 : 2012 AMD 1 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV
    EN 60076-1:2011 POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011)
    EN 50163 : 2004 COR 2013 RAILWAY APPLICATIONS - SUPPLY VOLTAGES OF TRACTION SYSTEMS
    IEC 60905:1987 Loading guide for dry-type power transformers
    EN 50121-5:2017 Railway applications - Electromagnetic compatibility - Part 5: Emission and immunity of fixed power supply installations and apparatus
    IEC 60076-2:2011 Power transformers - Part 2: Temperature rise for liquid-immersed transformers
    EN 61378-1:2011 Convertor transformers - Part 1: Transformers for industrial applications
    EN 60076-2:2011 Power transformers - Part 2: Temperature rise for liquid-immersed transformers
    EN 50328 : 2003 COR 2006 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRONIC POWER CONVERTERS FOR SUBSTATIONS
    IEC 61378-1:2011 Converter transformers - Part 1: Transformers for industrial applications
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective