1 Scope
2 Normative references
3 Physical quantities, units and constants
3.1 Physical quantities
3.2 Constants
4 Definitions
5 Measurement system specifications
5.1 General requirements
5.2 Phantom specifications (shell and liquid)
5.3 Specifications of the SAR measurement
equipment
5.4 Scanning system specifications
5.5 Mobile phone holder specifications
5.6 Other equipment
6 Protocol for SAR assessment
6.1 Measurement preparation
6.2 Tests to be performed
6.3 Measurement procedure
6.4 Post-processing
7 Uncertainty assessment
7.1 General requirements
7.2 Components contributing to uncertainty
7.3 Uncertainty assessment
8 Measurement report
8.1 General
8.2 Items to be recorded in the test report
Annex A (informative) Phantom specifications
A.1 Rationale for the phantom shape
A.2 Tissue equivalent liquids
A.3 Preparation of tissue equivalent
material
A.4 Measurement of the dielectric
properties
Annex B (informative) Calibration of the measurement
equipment (linearity, isotropy,
sensitivity) and uncertainty
assessment
B.1 Introduction
B.2 Assessment of the sensitivity of the
dipolar sensors
B.3 Isotropy
B.4 Linearity
B.5 Lower detection limit
B.6 Boundary effects
B.7 Response time
Annex C (informative) Post-processing techniques and
uncertainty assessment
C.1 Extrapolation and interpolation schemes
C.2 Averaging scheme and maximum finding
Annex D (informative) Measurement system validation
D.1 Simplified performance checking
D.2 System validation
Applicable to any electromagnetic field (EM) transmitting devices with the radiating part of the equipment in close proximity to the human ear including mobile phones, cordless phones, etc. The frequency range is 300 MHz to 3 GHz.
DocumentType |
Standard
|
Pages |
52
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
SN EN 50361 : 2001 | Identical |
DIN EN 50361 : 2002 | Identical |
UNE-EN 50361:2003 | Identical |
EN 50361:2001 | Identical |
NBN EN 50361 : 2002 | Identical |
NEN EN 50361 : 2001 | Identical |
NF EN 50361 : 2001 | Identical |
BS EN 50361:2001 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.