• I.S. EN 55016-1-4:2010

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-4: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNAS AND TEST SITES FOR RADIATED DISTURBANCE MEASUREMENTS

    Available format(s):  Hardcopy, PDF

    Superseded date:  12-02-2022

    Language(s):  English

    Published date:  01-01-2010

    Publisher:  National Standards Authority of Ireland

    For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
    Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

    Dates of withdrawal of national standards are available from NSAI.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    National Foreword
    FOREWORD
    INTRODUCTION (to Amendment 1)
    1 Scope
    2 Normative references
    3 Terms, definitions and abbreviations
    4 Antennas for measurement of radiated radio disturbance
    5 Test sites for measurement of radio disturbance field strength
      for the frequency range of 30 MHz to 1000 MHz
    6 Reverberating chamber for total radiated power measurement
    7 TEM cells for immunity to radiated disturbance measurement
    8 Test sites for measurement of radio disturbance field strength
      for the frequency range 1 GHz to 18 GHz
    9 Common mode absorption devices
    Annex A (normative) - Parameters of antennas
    Annex B (normative) - Monopole (1 m rod) antenna performance
            equations and characterization of the associated antenna
            matching network
    Annex C (normative) - Loop antenna system for magnetic field
            induced-current measurements in the frequency range of 9
            kHz to 30 MHz
    Annex D (normative) - Construction details for open area test
            sites in the frequency range of 30 MHz to 1000 MHz
    Annex E - Void
    Annex F (informative) - Basis for 4 dB site acceptability
            criterion
    Annex G (informative) - Examples of uncertainty budgets
            for site validation of a COMTS using RSM
            with a calibrated antenna pair
    Bibliography
    Annex ZA (normative) - Normative references to international
             publications with their corresponding European
             publications

    Abstract - (Show below) - (Hide below)

    Describes the characteristics and performance of equipment for the measurement of radiated disturbances in the frequency range 9 kHz to 18 GHz.

    General Product Information - (Show below) - (Hide below)

    Development Note For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (07/2017)
    Document Type Standard
    Publisher National Standards Authority of Ireland
    Status Superseded
    Superseded By

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 55016-1-6:2015/A1:2017 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-6: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - EMC ANTENNA CALIBRATION (CISPR 16-1-6:2014/A1:2017)
    CLC/TR 50484:2009 Recommendations for shielded enclosures
    IEC 61169-8:2007 Radio-frequency connectors - Part 8: Sectional specification - RF coaxial connectors with inner diameter of outer conductor 6,5 mm (0,256 in) with bayonet lock - Characteristic impedance 50 Ω (type BNC)
    CISPR 16-4-2:2011+AMD1:2014 CSV Specification for radio disturbance and immunity measuring apparatusand methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty
    EN 55016-2-3:2017 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements
    CISPR 16-1-1:2015 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus
    CISPR 16-1-5:2014+AMD1:2016 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and reference test sites for 5 MHz to 18 GHz
    EN 55016-1-5:2015/A1:2017 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-5: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNA CALIBRATION SITES AND REFERENCE TEST SITES FOR 5 MHZ TO 18 GHZ (CISPR 16-1-5:2014/A1:2016)
    MIL-STD-461 Revision G:2015 REQUIREMENTS FOR THE CONTROL OF ELECTROMAGNETIC INTERFERENCE CHARACTERISTICS OF SUBSYSTEMS AND EQUIPMENT
    IEC 61000-4-20:2010 Electromagnetic compatibility (EMC) - Part 4-20: Testing and measurement techniques - Emission and immunity testing in transverse electromagnetic (TEM) waveguides
    CISPR 16-2-3:2016 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements
    ANSI C63.5 : 2006 ELECTROMAGNETIC COMPATIBILITY - RADIATED EMISSION MEASUREMENTS IN ELECTROMAGNETIC INTERFERENCE (EMI) CONTROL - CALIBRATION AND QUALIFICATION OF ANTENNAS (9 KHZ TO 40 GHZ)
    ETR 273-1-1 : 20001 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); IMPROVEMENT OF RADIATED METHODS OF MEASUREMENT (USING TEST SITES) AND EVALUATION OF THE CORRESPONDING MEASUREMENT UNCERTAINTIES; PART 1 UNCERTAINTIES IN THE MEASUREMENT OF MOBILE RADIO EQUIPMENT CHARACTERISTICS; SUB-PART 1: INTRODUCTION
    EN 61000-4-20:2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-20: TESTING AND MEASUREMENT TECHNIQUES - EMISSION AND IMMUNITY TESTING IN TRANSVERSE ELECTROMAGNETIC (TEM) WAVEGUIDES
    CLC/TR 50481:2009 Recommendations on filters for shielded enclosures
    EN 55016-1-1:2010/A2:2014 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS (CISPR 16-1-1:2010/A2:2014)
    CISPR TR 16-3:2010+AMD1:2012+AMD2:2015 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 3: CISPR technical reports
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective