I.S. EN 55016-4-2:2011
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 4-2: UNCERTAINTIES, STATISTICS AND LIMIT MODELLING - MEASUREMENT INSTRUMENTATION UNCERTAINTY
Hardcopy , PDF
04-02-2020
English
14-10-2011
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions, symbols and abbreviations
4 Compliance criterion for the MIU
5 Conducted disturbance measurements
6 Disturbance power measurements
7 Radiated disturbance measurements in the
frequency range 30 MHz to 1000 MHz
8 Radiated disturbance measurements in the
frequency range 1 GHz to 18 GHz
Annex A (informative) - Basis for U(cispr) values
in Table 1, general information and
rationale for input quantities common to
all measurement methods
Annex B (informative) - Basis for U(cispr) values
in Table 1, uncertainty budgets and rationale
for conducted disturbance measurements
Annex C (informative) - Basis for U(cispr) values in
Table 1 - Disturbance power measurements
Annex C (informative) - Basis for U(cispr) values in
Table 1 - Disturbance power measurements
Annex D (informative) - Basis for U(cispr) values in
Table 1 - Radiated disturbance measurements
from 30 MHz to 1000 MHz
Annex E (informative) - Basis for U(cispr) values in
Table 1 - Radiated disturbance
measurements from 1 GHz to 18 GHz
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Defines the method of applying Measurement Instrumentation Uncertainty (MIU) when determining compliance with CISPR disturbance limits.
DocumentType |
Standard
|
Pages |
63
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NEN EN 55016-4-2 : 2011 AMD 1 2014 | Identical |
NF EN 55016-4-2 : 2012 AMD 1 2014 | Identical |
CISPR 16-4-2:2011+AMD1:2014 CSV | Identical |
DIN EN 55016-4-2 : 2014 | Identical |
UNE-EN 55016-4-2:2012 | Identical |
EN 55016-4-2:2011 | Identical |
BS EN 55016-4-2 : 2011 | Identical |
EN 55016-4-2:2011/A1:2014 | Identical |
CISPR 12:2007+AMD1:2009 CSV | Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of off-board receivers |
CISPR 13:2009+AMD1:2015 CSV | Sound and television broadcast receivers and associated equipment -Radio disturbance characteristics - Limits and methods of measurement |
EN 55016-2-3:2017 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements |
EN 55016-2-2:2011 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-2: Methods of measurement of disturbances and immunity - Measurement of disturbance power |
EN 55013:2013/A1:2016 | SOUND AND TELEVISION BROADCAST RECEIVERS AND ASSOCIATED EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 13:2009, MODIFIED) |
CISPR 16-2-2:2010 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-2: Methods of measurement of disturbances and immunity - Measurement of disturbance power |
EN 55016-1-4:2010/A2:2017 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-4: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNAS AND TEST SITES FOR RADIATED DISTURBANCE MEASUREMENTS (CISPR 16-1-4:2010/A2:2017) |
CISPR 16-1-4:2010+AMD1:2012+AMD2:2017 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements |
CISPR 16-1-1:2015 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus |
CISPR 16-1-3:2004+AMD1:2016 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-3: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Disturbance power |
CISPR 16-2-1:2014 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements |
CISPR TR 16-4-3:2004+AMD1:2006 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-3: Uncertainties, statistics and limit modelling - Statistical considerations in the determination of EMC compliance of mass-produced products |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
CISPR TR 16-4-1:2009 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-1: Uncertainties, statistics and limit modelling - Uncertainties in standardized EMC tests |
ISO/IEC Guide 99:2007 | International vocabulary of metrology Basic and general concepts and associated terms (VIM) |
EN 55022:2010/AC:2011 | INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008) |
CISPR 16-2-3:2016 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements |
EN 55016-1-3:2006/A1:2016 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-3: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANCILLARY EQUIPMENT - DISTURBANCE POWER (CISPR 16-1-3:2004) |
CISPR TR 16-4-4:2007 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-4: Uncertainties, statistics and limit modelling - Statistics of complaints and a model for the calculation of limits for the protection of radio services |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
EN 55012:2007/A1:2009 | VEHICLES, BOATS AND INTERNAL COMBUSTION ENGINES - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT FOR THE PROTECTION OF OFF-BOARD RECEIVERS |
EN 55016-2-1:2014/A1:2017 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 2-1: METHODS OF MEASUREMENT OF DISTURBANCES AND IMMUNITY - CONDUCTED DISTURBANCE MEASUREMENTS (CISPR 16-2-1:2014/A1:2017) |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
EN 55016-1-1:2010/A2:2014 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS (CISPR 16-1-1:2010/A2:2014) |
CISPR TR 16-3:2010+AMD1:2012+AMD2:2015 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 3: CISPR technical reports |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.