• I.S. EN 60034-18-42:2017&A1:2020

    Current The latest, up-to-date edition.

    Rotating electrical machines - Part 18-42: Partial discharge resistant electrical insulation systems (Type II) used in rotating electrical machines fed from voltage converters - Qualification tests

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  26-10-2020

    Publisher:  National Standards Authority of Ireland

    For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
    Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

    Dates of withdrawal of national standards are available from NSAI.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Machine terminal voltages arising from converter operation
    5 Electrical stresses in the insulation system of machine windings
    6 Voltage rating for Type II insulation systems
    7 Stress factors for converter-fed Type II insulation systems
    8 Qualification tests
    9 Qualification of mainwall insulation system
    10 Qualification of turn insulation
    11 Qualification of the stress control system
    12 Preparation of test objects
    13 Qualification test procedures
    14 Qualification test pass criteria
    15 Routine test
    16 Optional screening tests
    17 Analysis, reporting and classification
    Annex A (informative) Contributions to ageing of the mainwall insulation
    Annex B (informative) Examples of circuits for impulse testing
    Annex C (informative) Derivation of the short term endurance test voltage
    Annex D (informative) Derivation of the impulse voltage insulation class for the machine insulation
    Annex E (normative) Derivation of an IVIC in the absence of a manufacturer’s reference life line
    Annex F (informative) Optional screening tests
    Bibliography

    Abstract - (Show below) - (Hide below)

    This part of IEC 60034 defines criteria for assessing the insulation system of stator/rotor windings of single or polyphase AC machines which are subjected to repetitive impulse voltages, such as those generated by pulse width modulation (PWM) converters, and are expected to experience and withstand partial discharge activity during service.

    General Product Information - (Show below) - (Hide below)

    Committee TC 2
    Document Type Standard
    Product Note The date of any NSAI previous adoption may not match the date of its original CEN/CENELEC document.
    Publisher National Standards Authority of Ireland
    Status Current
    Supersedes
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective