I.S. EN 60168:1996
Current
The latest, up-to-date edition.
TESTS ON INDOOR AND OUTDOOR POST INSULATORS OF CERAMIC MATERIAL OR GLASS FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1000 V
Hardcopy , PDF
English
01-01-1996
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
Foreword
Introduction
Section 1. General
1.1 Scope and object
1.2 Normative references
1.3 Definitions
Section 2. Insulators
2.1 Insulator designs and insulating materials
2.2 Values which characterize a post insulator
2.3 Identification of insulators
Section 3. Classification of the tests, sampling
rules and procedures
3.1 Classification of the tests
3.2 Quality assurance
3.3 General requirements for type tests
3.4 General requirements for sample tests
Section 4. Test procedures for electrical tests
4.1 General requirements for high-voltage tests
4.2 Standard atmospheric conditions and correction
factors for electrical tests
4.3 Artificial rain parameters for wet tests
4.4 Mounting arrangements for electrical tests
4.5 Dry lightning-impulse withstand voltage test-Type test
4.6 Dry or wet switching-impulse withstand voltage tests
- Type test
4.7 Dry power-frequency withstand voltage test - Type test
(applicable only to post insulators for indoor use)
4.8 Wet power-frequency withstand voltage test - Type test
(applicable only to post insulators for outdoor use)
4.9 Puncture test - Sample test
4.10 Routine electrical test
Section 5. Test procedures for mechanical and other tests
5.1 Verification of the dimensions - Type and sample test
5.2 Mechanical failing load test - Type and sample test
5.3 Test for deflection under load - Special type test
5.4 Temperature cycle test - Sample test
5.5 Routine thermal shock test (applicable only to
toughened glass insulating parts)
5.6 Porosity test - Sample test (applicable only to
ceramic post insulators)
5.7 Galvanizing test - Sample test
5.8 Routine visual inspection
5.9 Routine mechanical test
Section 6. Tests applicable to post insulators
6.1 Type tests
6.2 Sample tests
6.3 Routine tests
6.4 Summary of tests on post insulators
Annex A (informative) Methods of testing for tolerances
of parallelism, eccentricity, angular deviation,
camber and shed angle of post insulators
Annex B (informative) Methods of routine testing of
unassembled insulator units
Annex C (informative) Bibliography
Annex ZA (normative) Other international publications
quoted in this standard with the references of
the relevant European publications
Applies to post insulators and post insulator units of ceramic material r glass for indoor and outdoor service in electrical installations or equipment operating on electric current with a nominal voltage greater than 1000 V and a frequency not greater than 100 Hz.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
130
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Standards | Relationship |
NF EN 60168 : 95 AMD 2 2001 | Identical |
UNE-EN 60168:1997 | Identical |
SN EN 60168 : 1994 AMD 2 2000 | Identical |
EN 60168:1994/A2:2000 | Identical |
IEC 60168:1994+AMD1:1997+AMD2:2000 CSV | Identical |
NBN EN 60168 : 1995 AMD 2 2001 | Identical |
BS EN 60168:1995 | Identical |
DIN EN 60168 : 2001-12 | Identical |