• I.S. EN 60255-26:2013

    Current The latest, up-to-date edition.

    MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 26: ELECTROMAGNETIC COMPATIBILITY REQUIREMENTS (IEC 60255-26:2013 (EQV))

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  01-01-2013

    Publisher:  National Standards Authority of Ireland

    For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
    Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

    Dates of withdrawal of national standards are available from NSAI.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Definition of environmental levels
    5 Emission
    6 Immunity
    7 Test set-up and procedures
    8 Criteria for acceptance
    9 Test report
    Annex A (normative) - Power frequency immunity tests on
            binary inputs
    Annex B (informative) - Background information for power
            frequency tests
    Annex C (normative) - Application of discharges for electrostatic
            discharge test
    Bibliography
    Annex ZA (normative) - Normative references to international
             Publications with their corresponding
             European publications
    Annex ZZ (informative) - Coverage of Essential Requirements
              of EC Directives

    Abstract - (Show below) - (Hide below)

    Describes the requirements for electromagnetic compatibility for measuring relays and protection equipment.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes I.S. EN 50263. (02/2010) Supersedes I.S EN 60255-11, I.S. EN 60255-22-1, I.S. EN 60255-22-2, I.S. EN 60255-22-3, I.S. EN 60255-22-4, I.S. EN 60255-22-5, I.S. EN 60255-22-6, I.S. EN 60255-22-7 & I.S. EN 60255-25. (09/2013) For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply.(01/2017)
    Document Type Standard
    Publisher National Standards Authority of Ireland
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61000-4-8 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-8: TESTING AND MEASUREMENT TECHNIQUES - POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST
    IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
    EN 61000-4-11:2004/A1:2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017)
    IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
    IEC 61000-4-17:1999+AMD1:2001+AMD2:2008 CSV Electromagnetic compatibility (EMC) - Part 4-17: Testing and measurement techniques - Ripple on d.c. input power port immunity test
    EN 61000-4-2:2009 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
    IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
    CISPR 22:2008 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
    EN 61000-4-3 : 2006 AMD 2 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
    EN 60255-1:2010 Measuring relays and protection equipment - Part 1: Common requirements
    EN 55022:2010/AC:2011 INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008)
    IEC TS 61000-6-5:2001 Electromagnetic compatibility (EMC) - Part 6-5: Generic standards - Immunity for power station and substation environments
    EN 61000-4-8:2010 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
    IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
    IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
    IEC 60255-1:1967 Electrical relays - Part 1: Instantaneous all-or-nothing relays
    EN 61000-4-4:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012)
    CISPR 11:2015 RLV Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
    EN 61000-4-6:2014/AC:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013)
    EN 61000-4-16:2016 Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz
    IEC 61000-4-29:2000 Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
    EN 61000-4-17:1999/A2:2009 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-17: TESTING AND MEASUREMENT TECHNIQUES - RIPPLE ON D.C. INPUT POWER PORT IMMUNITY TEST
    IEC 61000-4-18:2006+AMD1:2010 CSV Electromagnetic compatibility (EMC) - Part 4-18: Testing and measurement techniques - Damped oscillatory wave immunity test
    EN 61000-4-29:2000 Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
    IEC 61000-4-16 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-16: TESTING AND MEASUREMENT TECHNIQUES - TEST FOR IMMUNITY TO CONDUCTED, COMMON MODE DISTURBANCES IN THE FREQUENCY RANGE 0 HZ TO 150 KHZ
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective