I.S. EN 60265-1:1999

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

HIGH-VOLTAGE SWITCHES - SWITCHES FOR RATED VOLTAGES ABOVE 1 KV AND LESS THAN 52 KV

Available format(s)

Hardcopy , PDF

Superseded date

06-09-2011

Superseded by

I.S. EN 62271-103:2011

Language(s)

English

Published date

01-01-1999

For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.

Only cited Standards give presumption of conformance to New Approach Directives/Regulations.


Dates of withdrawal of national standards are available from NSAI.

€104.00
Excluding VAT

1 General
    1.1 Scope
    1.2 Normative references
          1.101 General requirements
2 Normal and special service conditions
3 Definitions
    3.1 General terms
    3.2 Assemblies
    3.3 Parts of assemblies
    3.4 Switching devices
    3.5 Parts of switching devices
    3.6 Operation
    3.7 Characteristic quantities
    3.8 Index of definitions
4 Ratings
    4.1 Rated voltage (Ur)
    4.2 Rated insulation level
    4.3 Rated frequency (fr)
    4.4 Rated normal current (lr) and temperature rise
    4.5 Rated short-time withstand current (lk)
    4.6 Rated peak withstand current (lp)
    4.7 Rated duration of short-circuit (tk)
    4.8 Rated supply voltage of closing and opening devices
          and of auxiliary and control circuits (Ua)
    4.9 Rated supply frequency of closing and opening
          devices and of auxiliary circuits
    4.10 Rated pressure of compressed gas supply for operation
          and/or interruption
          4.101 Rated mainly active load-breaking current (l1)
          4.102 Rated closed-loop breaking current (l2a and l2b)
          4.103 Rated no-load transformer breaking current (l3)
          4.104 Rated cable-charging breaking current (l4a)
          4.105 Rated line-charging breaking current (l4b)
          4.106 Rated single capacitor bank breaking current for
                 special purpose switches (l4c)
          4.107 Rated back-to-back capacitor bank breaking
                 current for special purpose switches (l4d)
          4.108 Rated back-to-back capacitor inrush making
                 current for special purpose switches (lin)
          4.109 Rated earth fault breaking current (l6a)
          4.110 Rated cable- and line-charging breaking
                 current under earth fault conditions (l6b)
          4.111 Rated motor breaking current for special
                 purpose switches (l7)
          4.112 Rated short-circuit making current (lma)
          4.113 Rated breaking and making currents for a
                 general purpose switch
          4.114 Ratings for limited purpose switches
          4.115 Ratings for special purpose switches
          4.116 Ratings for switches backed by fuses
5 Design and construction
    5.1 Requirements for liquids in high-voltage switches
    5.2 Requirements for gases in high-voltage switches
    5.3 Earthing of high-voltage switches
    5.4 Auxiliary and control equipment
    5.5 Dependent power operation
    5.6 Stored energy operation
    5.7 Independent manual operation
    5.8 Operation of releases
    5.9 Low- and high-pressure interlocking and monitoring
          devices
    5.10 Nameplates
    5.11 Interlocking devices
    5.12 Position indication
    5.13 Degrees of protection by enclosures
    5.14 Creepage distances
    5.15 Gas and vacuum tightness
    5.16 Liquid tightness
    5.17 Flammability
    5.18 Electromagnetic compatibility (EMC)
          5.101 Making and breaking operations
          5.102 Requirements for switch-disconnectors
          5.103 Mechanical strength
          5.104 Securing the position
          5.105 Auxiliary contacts for signalling
6 Type tests
    6.1 General
    6.2 Dielectric tests
    6.3 Radio interference voltage (RIV) tests
    6.4 Measurement of the resistance of the main circuit
    6.5 Temperature-rise tests
    6.6 Short-time withstand current and peak withstand current
          tests
    6.7 Verification of the protection
    6.8 Tightness tests
    6.9 Electromagnetic compatibility (EMC) tests
          6.101 Making and breaking tests
          6.102 Mechanical operation tests
          6.103 Operation under severe ice conditions
7 Routine tests
          7.101 Mechanical operating tests
8 Guide to the selection of high-voltage switches for service
    8.1 General
    8.2 Conditions affecting application
    8.3 Insulation coordination
    8.4 Selection of class of switch
9 Information to be given with inquiries, tenders and orders
    9.1 Information to be given with inquiries and orders
          9.102 Information to be given with tenders
10 Rules for transport, storage, erection, operation and
    maintenance
11 Safety
Tables
1 Rated line- and cable-charging breaking currents for
    general purpose switch
2 Nameplate information
3 Supply circuit TRV parameters for mainly active load
    current breaking tests
4a TRV parameters for distribution line closed loop breaking
    tests
4b TRV parameters for parallel power transformer current
    breaking tests
5 Test duties for general purpose switches - Test duties
    for three-phase tests on three-pole operated,
    pole-after-pole operated, and single pole switches
6 Test duties for general purpose switches - Single phase
    tests on three-pole switches operated pole-after-pole and
    single-pole switches applied on three-phase systems
7 Test duties for special purpose switches - Three-phase
    tests on three-pole operated, pole-after-pole operated,
    and single-pole switches
8 Test duties for special purpose switches - Single phase
    tests on three-pole switches operated pole-after-pole and
    single-pole switches applied on three-phase systems
9 Prospective recovery voltage parameter limits for
    single-phase capacitor bank current breaking tests
Figures
1 Three-phase test circuit for mainly active load current
    switching for test duty 1
2 Single-phase test circuit for mainly active load current
    switching for test duty 1
3 Three-phase test circuit for distribution line closed-loop
    and parallel transformer current switching test for test
    duties 2a and 2b
4 Single-phase test circuit for distribution line closed-loop
    and parallel transformer current switching test, for test
    duties 2a and 2b
5 Three-phase test circuit for short-circuit making current
    test for test duty 5
6 Single-phase test circuit for short-circuit making current
    test for test duty 5
7 Prospective TRV parameter limits for single-phase capacitor
    bank current breaking tests
8 Three-phase test circuit for earth fault breaking current
    tests, for test duty 6a
9 Three-phase test circuit for cable-charging breaking
    current tests under earth fault conditions, for test duty
    6b
Annex ZA Normative references to international publications
with their corresponding European publications

Applies to three-phase, alternating current switches and switch-disconnectors having making and breaking current ratings, for indoor and outdoor installations, for rated voltages above 1 kV and less than 52 kV and for rated frequencies from 16 2/3 Hz up to and including 60 Hz. Also applies to the operating devices of theses switches and to their auxiliary equipment.

DocumentType
Standard
Pages
110
PublisherName
National Standards Authority of Ireland
Status
Superseded
SupersededBy

Standards Relationship
NF EN 60265-1 : 2001 Identical
DIN EN 60265-1 : 1999 Identical
EN 60265-1:1998 Identical
SN EN 60265-1 : 1998 Identical
BS EN 60265-1:1998 Identical
NBN EN 60265-1 : 1998 Identical
UNE-EN 60265-1:1999 Identical