I.S. EN 60601-2-10:2015
Current
The latest, up-to-date edition.
MEDICAL ELECTRICAL EQUIPMENT - PART 2-10: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF NERVE AND MUSCLE STIMULATORS
Hardcopy , PDF
English
01-01-2015
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
National Foreword
FOREWORD
INTRODUCTION
201.1 Scope, object and related standards
201.2 Normative references
201.3 Terms and definitions
201.4 General requirements
201.5 General requirements for testing of ME
EQUIPMENT
201.6 Classification of ME EQUIPMENT and
ME SYSTEMS
201.7 ME EQUIPMENT identification, marking
and documents
201.8 Protection against electrical HAZARDS from
ME EQUIPMENT
201.9 Protection against MECHANICAL HAZARDS
of ME EQUIPMENT and ME SYSTEMS
201.10 Protection against unwanted and excessive radiation
HAZARDS
201.11 Protection against excessive temperatures and other
HAZARDS
201.12 Accuracy of controls and instruments and protection
against hazardous outputs
201.13 HAZARDOUS SITUATIONS and fault conditions for
ME EQUIPMENT
201.14 PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS)
201.15 Construction of ME EQUIPMENT
201.16 ME SYSTEMS
201.17 Electromagnetic compatibility of ME EQUIPMENT
and ME SYSTEMS
202 Electromagnetic disturbances - requirements and tests
Annexes
Annex C (informative) - Guide to marking and labelling
requirements for ME EQUIPMENT and ME SYSTEMS
Annex AA (informative) - Particular guidance and rationale
Index of defined terms used in this particular standard
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Annex ZZ (informative) - Coverage of Essential
Requirements of EU Directives
Describes the requirements for the safety of nerve and Muscle STIMULATORS, defined in subclause 201.3.204, for use in the practice of physical medicine, hereinafter referred to as ME EQUIPMENT.
DevelopmentNote |
Supersedes I.S. HD 395-2-10. (03/2011) For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
72
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Supersedes |
Standards | Relationship |
DIN EN 60601-2-10 : 2017 | Identical |
NF EN 60601-2-10 : 2015 AMD 1 2017 | Identical |
BS EN 60601-2-10:2015 | Identical |
UNE-EN 60601-2-10:2001 | Identical |
EN 60601-2-10:2015/A1:2016 | Identical |
SN EN 60601-2-10 : 2015 + A1 2017 | Identical |
EN 60601-2-10:2015/A1:2016 | Identical |
IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
EN 60601-1-2:2015 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.