• I.S. EN 60601-2-10:2015

    Current The latest, up-to-date edition.

    MEDICAL ELECTRICAL EQUIPMENT - PART 2-10: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF NERVE AND MUSCLE STIMULATORS

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  01-01-2015

    Publisher:  National Standards Authority of Ireland

    For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
    Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

    Dates of withdrawal of national standards are available from NSAI.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    National Foreword
    FOREWORD
    INTRODUCTION
    201.1 Scope, object and related standards
    201.2 Normative references
    201.3 Terms and definitions
    201.4 General requirements
    201.5 General requirements for testing of ME
           EQUIPMENT
    201.6 Classification of ME EQUIPMENT and
           ME SYSTEMS
    201.7 ME EQUIPMENT identification, marking
           and documents
    201.8 Protection against electrical HAZARDS from
           ME EQUIPMENT
    201.9 Protection against MECHANICAL HAZARDS
           of ME EQUIPMENT and ME SYSTEMS
    201.10 Protection against unwanted and excessive radiation
           HAZARDS
    201.11 Protection against excessive temperatures and other
           HAZARDS
    201.12 Accuracy of controls and instruments and protection
           against hazardous outputs
    201.13 HAZARDOUS SITUATIONS and fault conditions for
           ME EQUIPMENT
    201.14 PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS)
    201.15 Construction of ME EQUIPMENT
    201.16 ME SYSTEMS
    201.17 Electromagnetic compatibility of ME EQUIPMENT
           and ME SYSTEMS
    202 Electromagnetic disturbances - requirements and tests
    Annexes
    Annex C (informative) - Guide to marking and labelling
            requirements for ME EQUIPMENT and ME SYSTEMS
    Annex AA (informative) - Particular guidance and rationale
    Index of defined terms used in this particular standard
    Annex ZA (normative) - Normative references to
             international publications with their
             corresponding European publications
    Annex ZZ (informative) - Coverage of Essential
             Requirements of EU Directives

    Abstract - (Show below) - (Hide below)

    Describes the requirements for the safety of nerve and Muscle STIMULATORS, defined in subclause 201.3.204, for use in the practice of physical medicine, hereinafter referred to as ME EQUIPMENT.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes I.S. HD 395-2-10. (03/2011) For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
    Document Type Standard
    Publisher National Standards Authority of Ireland
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
    IEC 60601-1-2:2014 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
    EN 60601-1-2:2015 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective