I.S. EN 60601-2-26:2015
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
MEDICAL ELECTRICAL EQUIPMENT - PART 2-26: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF ELECTROENCEPHALOGRAPHS
Hardcopy , PDF
29-05-2023
English
01-01-2015
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
FOREWORD
INTRODUCTION
201.1 Scope, object and related standards
201.2 Normative references
201.3 Terms and definitions
201.4 General requirements
201.5 General requirements for testing of
ME EQUIPMENT
201.6 Classification of ME EQUIPMENT and
ME SYSTEMS
201.7 ME EQUIPMENT identification, marking
and documents
201.8 Protection against electrical HAZARDS
from ME EQUIPMENT
201.9 Protection against MECHANICAL HAZARDS
of ME EQUIPMENT and ME SYSTEMS
201.10 Protection against unwanted and excessive
radiation HAZARDS
201.11 Protection against excessive temperatures
and other HAZARDS
201.12 Accuracy of controls and instruments and
protection against hazardous outputs
201.13 HAZARDOUS SITUATIONS and fault
conditions
201.14 PROGRAMMABLE ELECTRICAL MEDICAL
SYSTEMS (PEMS)
201.15 Construction of ME EQUIPMENT
201.16 ME SYSTEMS
201.17 ELECTROMAGNETIC COMPATIBILITY of
ME EQUIPMENT and ME SYSTEMS
202 ELECTROMAGNETIC COMPATIBILITY - Requirements
and tests
Annexes
Annex AA (informative) - Particular guidance and rationale
Index of defined terms used in this particular standard
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Annex ZZ (informative) - Coverage of Essential
Requirements of EU Directives
Pertains to BASIC SAFETY and ESSENTIAL PERFORMANCE of ELECTROENCEPHALOGRAPHS (EEG) as defined in 201.3.63, hereafter referred to as ME EQUIPMENT.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
70
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
Standards | Relationship |
UNE-EN 60601-2-26:2004 | Identical |
EN 60601-2-26:2015 | Identical |
BS EN 60601-2-26:2015 | Identical |
DIN EN 60601-2-26 : 2016 | Identical |
SN EN 60601-2-26 : 2003 | Identical |
NF EN 60601-2-26 : 2015 | Identical |
IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
EN 60601-2-27:2014 | Medical electrical equipment - Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment |
IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
EN 60601-1-2:2015 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
IEC 60601-2-27:2011 | Medical electrical equipment - Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.