I.S. EN 60645-1:2017
Current
The latest, up-to-date edition.
ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AND SPEECH AUDIOMETRY
Hardcopy , PDF
English
01-01-2017
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
National Foreword
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements by type and class of audiometer
5 General requirements
6 Test signals
7 Transducers
8 Signal level control
9 Reference tone
10 Calibration
11 Electrical output of test signals
12 Audiogram format
13 Test requirements to demonstrate conformity
14 Maximum permitted expanded uncertainty of
measurements U[max]
15 Marking and instruction manual
Annex A (informative) - Relationship between tolerance
interval, corresponding acceptance interval and the
maximum permitted uncertainty of measurement
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Defines general requirements for audiometers designed for use in determining hearing threshold levels, relative to standard reference threshold levels established by means of psychoacoustic test methods, and those designed to perform psychoacoustic tests using speech material.
DevelopmentNote |
Supersedes I.S. EN 60645-4. (05/2015) For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
100
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Supersedes |
Standards | Relationship |
SN EN 60645-1 : 1994 | Identical |
DIN EN 60645-1:2015-11 | Identical |
NBN EN 60645-1 : 2015 | Identical |
EN 60645-1:2017 | Identical |
BS EN 60645-1:2015 | Identical |
UNE-EN 60645-1:2015 | Identical |
BS EN 60645-1:2017 | Identical |
IEC 60318-4:2010 | Electroacoustics - Simulators of human head and ear - Part 4: Occluded-ear simulator for the measurement of earphones coupled to the ear by means of ear inserts |
IEC 60268-3:2013 | Sound system equipment - Part 3: Amplifiers |
EN 60268-7:2011 | Sound system equipment - Part 7: Headphones and earphones |
IEC 60318-6:2007 | Electroacoustics - Simulators of human head and ear - Part 6: Mechanical coupler for the measurement on bone vibrators |
ISO 389-4:1994 | Acoustics Reference zero for the calibration of audiometric equipment Part 4: Reference levels for narrow-band masking noise |
ISO 389-7:2005 | Acoustics Reference zero for the calibration of audiometric equipment Part 7: Reference threshold of hearing under free-field and diffuse-field listening conditions |
EN 60318-1:2009 | Electroacoustics - Simulators of human head and ear - Part 1: Ear simulator for the measurement of supra-aural and circumaural earphones |
IEC 60318-3:2014 | Electroacoustics - Simulators of human head and ear - Part 3: Acoustic coupler for the calibration of supra-aural earphones used in audiometry |
IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
EN ISO 8253-3:2012 | Acoustics - Audiometric test methods - Part 3: Speech audiometry (ISO 8253-3:2012) |
ISO 266:1997 | Acoustics — Preferred frequencies |
EN 61260-1:2014 | Electroacoustics - Octave-band and fractional-octave-band filters - Part 1: Specifications |
EN ISO 389-8:2004 | Acoustics - Reference zero for the calibration of audiometric equipment - Part 8: Reference equivalent threshold sound pressure levels for pure tones and circumaural earphones (ISO 389-8:2004) |
ISO 8253-3:2012 | Acoustics Audiometric test methods Part 3: Speech audiometry |
ISO 389-9:2009 | Acoustics Reference zero for the calibration of audiometric equipment Part 9: Preferred test conditions for the determination of reference hearing threshold levels |
EN ISO 389-4:1998 | Acoustics - Reference zero for the calibration of audiometric equipment - Part 4: Reference levels for narrow-band masking noise (ISO 389-4:1994) |
ISO 4869-1:1990 | Acoustics Hearing protectors Part 1: Subjective method for the measurement of sound attenuation |
EN ISO 389-3:2016 | Acoustics - Reference zero for the calibration of audiometric equipment - Part 3: Reference equivalent threshold vibratory force levels for pure tones and bone vibrators (ISO 389-3:2016) |
IEC 60268-7:2010 | Sound system equipment - Part 7: Headphones and earphones |
EN 24869-1:1992 | Acoustics - Hearing protectors - Subjective method for the measurement of sound attenuation (ISO 4869-1:1990) |
ISO 389-8:2004 | Acoustics — Reference zero for the calibration of audiometric equipment — Part 8: Reference equivalent threshold sound pressure levels for pure tones and circumaural earphones |
EN ISO 389-2:1996 | Acoustics - Reference zero for the calibration of audiometric equipment - Part 2: Reference equivalent threshold sound pressure levels for pure tones and insert earphones (ISO 389-2:1994) |
ISO 389-5:2006 | Acoustics Reference zero for the calibration of audiometric equipment Part 5: Reference equivalent threshold sound pressure levels for pure tones in the frequency range 8 kHz to 16 kHz |
EN ISO 389-5:2006 | Acoustics - Reference zero for the calibration of audiometric equipment - Part 5: Reference equivalent threshold sound pressure levels for pure tones in the frequency range 8 kHz to 16 kHz (ISO 389-5:2006) |
IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
EN 60601-1-2:2015 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
IEC 60318-5:2006 | Electroacoustics - Simulators of human head and ear - Part 5: 2 cm<sup>3</sup> coupler for the measurement of hearing aids and earphones coupled to the ear by means of ear inserts |
EN ISO 8253-2:2009 | Acoustics - Audiometric test methods - Part 2: Sound field audiometry with pure-tone and narrow-band test signals (ISO 8253-2:2009) |
EN 61672-1:2013 | Electroacoustics - Sound level meters - Part 1: Specifications |
ISO 389-1:1998 | Acoustics Reference zero for the calibration of audiometric equipment Part 1: Reference equivalent threshold sound pressure levels for pure tones and supra-aural earphones |
EN 60268-3:2013 | Sound system equipment - Part 3: Amplifiers |
ISO 8253-1:2010 | Acoustics Audiometric test methods Part 1: Pure-tone air and bone conduction audiometry |
EN ISO 8253-1:2010 | Acoustics - Audiometric test methods - Part 1: Pure-tone air and bone conduction audiometry (ISO 8253-1:2010) |
IEC 61260-1:2014 | Electroacoustics - Octave-band and fractional-octave-band filters - Part 1: Specifications |
ISO 389-2:1994 | Acoustics Reference zero for the calibration of audiometric equipment Part 2: Reference equivalent threshold sound pressure levels for pure tones and insert earphones |
ISO 389-3:2016 | Acoustics Reference zero for the calibration of audiometric equipment Part 3: Reference equivalent threshold vibratory force levels for pure tones and bone vibrators |
EN ISO 266:1997 | Acoustics - Preferred frequencies (ISO 266:1997) |
EN 60318-5 : 2006 | ELECTROACOUSTICS - SIMULATORS OF HUMAN HEAD AND EAR - PART 5: 2 CM[3] COUPLER FOR THE MEASUREMENT OF HEARING AIDS AND EARPHONES COUPLED TO THE EAR BY MEANS OF EAR INSERTS |
EN 60318-3:2015 | Electroacoustics - Simulators of human head and ear - Part 3: Acoustic coupler for the calibration of supra-aural earphones used in audiometry |
IEC 60268-17:1990 | Sound system equipment. Part 17: Standard volume indicators |
IEC 60318-1:2009 | Electroacoustics - Simulators of human head and ear - Part 1: Ear simulator for the measurement of supra-aural and circumaural earphones |
ISO 8253-2:2009 | Acoustics Audiometric test methods Part 2: Sound field audiometry with pure-tone and narrow-band test signals |
HD 483.17 : 200S1 | SOUND SYSTEM EQUIPMENT - STANDARD VOLUME INDICATORS |
EN 60318-6:2008 | Electroacoustics - Simulators of human head and ear - Part 6: Mechanical coupler for the measurement of bone vibrators |
EN 60318-4:2010 | Electroacoustics - Simulators of human head and ear - Part 4: Occluded-ear simulator for the measurement of earphones coupled to the ear by means of ear inserts |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.