• I.S. EN 60708:2005

    Current The latest, up-to-date edition.

    LOW-FREQUENCY CABLES WITH POLYOLEFIN INSULATION AND MOISTURE BARRIER POLYOLEFIN SHEATH

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  01-01-2005

    Publisher:  National Standards Authority of Ireland

    For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
    Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

    Dates of withdrawal of national standards are available from NSAI.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    National Foreword
    FOREWORD
    1 Scope
    2 Normative references
    3 Quality assurance
    4 Cable construction
    5 Mechanical requirements
    6 Thermal stability and environmental requirements
    7 Electrical requirements
    Annex A (normative) - Colour code: 10 pair or 5 quad count
    Annex B (normative) - Colour code: sub-unit identification for
            50 pair (25 quad) and 100 pair (50 quad) cables or units,
            using 10 pair or 5 quad count
    Annex C (normative) - Colour code: 25 pair count
    Annex D (normative) - Colour code: unit identification for
            50 pair or quad and 100 pair or quad cables or units,
            using 25 pair or quad count
    Annex E (normative) - Colour code: 25 quad count
    Annex F (normative) - Colour code: unit identification for cables
            with more than 100 pairs, 25 pair count
    Annex G (normative) - Colour code: unit identification for cables
            with more than 100 pairs or 50 quads, using 10 pair or
            5 quad count or 25 quad count
    Annex ZA (normative) - Normative references to
             international publications with their
             corresponding European publications

    Abstract - (Show below) - (Hide below)

    Comprises of general design details and requirements for dimensions and other constructional details as well as mechanical, electrical and environmental characteristics for all types of low-frequency cables with polyolefin insulation (solid or cellular), filled or unfilled, and moisture barrier polyolefin sheath (with integral suspension strand).

    General Product Information - (Show below) - (Hide below)

    Development Note For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
    Document Type Standard
    Publisher National Standards Authority of Ireland
    Status Current

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60028:1925 International standard of resistance for copper
    IEC 60811-4-1:2004 Insulating and sheathing materials of electric and optical cables - Common test methods - Part 4-1: Methods specific to polyethylene and polypropylene compounds - Resistance to environmental stress cracking - Measurement of the melt flow index - Carbon black and/or mineral filler content measurement in polyethylene by direct combustion - Measurement of carbon black content by thermogravimetric analysis (TGA) - Assessment of carbon black dispersion in polyethylene using a microscope
    IEC 60189-1:2007 Low-frequency cables and wires with PVC insulation and PVC sheath - Part 1: General test and measuring methods
    IEC 60304:1982 Standard colours for insulation for low-frequency cables and wires
    EN 60811-1-3:1995/A1:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-3: GENERAL APPLICATION - METHODS FOR DETERMINING THE DENSITY - WATER ABSORPTION TESTS - SHRINKAGE TEST
    EN 60811-4-2:2004 Insulating and sheathing materials of electric and optical cables - Common test methods - Part 4-2: Methods specific to polyethylene and polypropylene compounds - Tensile strength and elongation at break after conditioning at elevated temperature - Wrapping test after conditioning at elevated temperature - Wrapping test after thermal ageing in air - Measurement of mass increase - Long-term stability test - Test method for copper-catalyzed oxidative degradation
    IEC 60794-1-2:2017 Optical fibre cables - Part 1-2: Generic specification - Basic optical cable test procedures - General guidance
    EN 60811-5-1:1999/A1:2004 INSULATING AND SHEATHING MATERIALS OF ELECTRIC AND OPTICAL CABLES - COMMON TEST METHODS - PART 5-1: METHODS SPECIFIC TO FILLING COMPOUNDS - DROP POINT - SEPARATION OF OIL - LOWER TEMPERATURE BRITTLENESS - TOTAL ACID NUMBER - ABSENCE OF CORROSIVE COMPONENTS - PERMITTIVITY AT 23 DEGREE C - D.C. RESISTIVITY AT 23 DEGREE C AND 100 DEGREE C
    IEC 60811-1-2:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Two: Thermal ageing methods
    IEC 61156-1:2007+AMD1:2009 CSV Multicore and symmetrical pair/quad cables for digital communications - Part 1: Generic specification
    EN 60794-1-2:2017/AC:2017-07 OPTICAL FIBRE CABLES - PART 1-2: GENERIC SPECIFICATION - BASIC OPTICAL CABLE TEST PROCEDURES - GENERAL GUIDANCE (IEC 60794-1-2:2017)
    EN 60811-4-1:2004 Insulating and sheathing materials of electric and optical cables - Common test methods - Part 4-1: Methods specific to polyethylene and polypropylene compounds - Resistance to environmental stress cracking - Measurement of the melt flow index - Carbon black and/or mineral filler content measurement in polyethylene by direct combustion - Measurement of carbon black content by thermogravimetric analysis (TGA) - Assessment of carbon black dispersion in polyethylene using a microscope
    EN 60811-1-2:1995/A2:2000 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - THERMAL AGEING METHODS
    IEC 60811-4-2:2004 Insulating and sheathing materials of electric and optical cables - Common test methods - Part 4-2: Methods specific to polyethylene and polypropylene compounds - Tensile strength and elongation at break after conditioning at elevated temperature - Wrapping test after conditioning at elevated temperature - Wrapping test after thermal ageing in air - Measurement of mass increase - Long-term stability test - Test method for copper-catalyzed oxidative degradation
    HD 402 : 200S2 STANDARD COLOURS FOR INSULATION FOR LOW-FREQUENCY CABLES AND WIRES
    IEC 60811-1-1:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
    IEC 60811-5-1:1990+AMD1:2003 CSV Insulating and sheathing materials of electric and optical cables - Common test methods - Part 5-1: Methods specific to filling compounds - Drop-point - Separation of oil - Lower temperature brittleness - Total acid number - Absence of corrosive components - Permittivity at 23 °C - DC resistivity at 23 °C and 100 °C
    IEC 60811-1-3:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric and optical cables - Part 1-3: General application -Methods for determining the density - Water absorption tests - Shrinkage test
    IEC 60811-1-4:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Four: Tests at low temperature
    EN 60811-1-1:1995/A1:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TESTS FOR DETERMINING MECHANICAL PROPERTIES
    EN 60811-1-4:1995/A2:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-4: GENERAL APPLICATION - TESTS AT LOW TEMPERATURE
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective