I.S. EN 60730-2-19:2002
Current
The latest, up-to-date edition.
AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE - PART 2-19: PARTICULAR REQUIREMENTS FOR ELECTRICALLY OPERATED OIL VALVES, INCLUDING MECHANICAL REQUIREMENTS
Hardcopy , PDF
English
01-01-2002
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
FOREWORD
1 Scope and normative references
2 Definitions
3 General requirements
4 General notes an tests
5 Rating
6 Classification
7 Information
8 Protection against electric shock
9 Provision for protective earthing
10 Terminals and terminations
11 Constructional requirements
12 Moisture and dust resistance
13 Electric strength and insulation resistance
14 Heating
15 Manufacturing deviation and drift
16 Environmental stress
17 Endurance
18 Mechanical strength
19 Threaded parts and connections
20 Creepage distances, clearances and distances through
solid insulation
21 Resistance to heat, fire and tracking
22 Resistance to corrosion
23 Electromagnetic compatibility (EMC) requirements - emission
24 Components
25 Normal operation
26 Electromagnetic compatibility (EMC) requirements - immunity
27 Abnormal operation
28 Guidance an the use of electronic disconnection
Figures
Annexes
Annex H (normative) Requirements for electronic controls
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Relates to electrically operated oil valves for use in, on or in association with equipment for household and similar use that use electricity, in combination with fuel in the liquid state such as distillates, residual fuels, etc.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
92
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Standards | Relationship |
IEC 60730-2-19:1997+AMD1:2000+AMD2:2007 CSV | Identical |
DIN EN 60730-2-19 : 2009-01 | Identical |
SN EN 60730-2-19 : 2002 AMD 11 2005 | Identical |
EN 60730-2-19:2002/A2:2008 | Identical |
BS EN 60730-2-19 : 2002 | Identical |
UNE-EN 60730-2-19:2003 | Identical |
NF EN 60730-2-19 : 2002 AMD 2 2008 | Identical |
EN 60730-2-14:1997/A2:2008 | AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE - PART 2-14: PARTICULAR REQUIREMENTS FOR ELECTRIC ACTUATORS |
ISO 4400:1994 | Fluid power systems and components — Three-pin electrical plug connectors with earth contact — Characteristics and requirements |
EN 264 : 1991 | SAFETY SHUT OFF DEVICES FOR COMBUSTION PLANTS USING LIQUID FUELS - SAFETY REQUIREMENTS AND TESTING |
ISO 7005-2:1988 | Metallic flanges — Part 2: Cast iron flanges |
ISO 274:1975 | Copper tubes of circular section — Dimensions |
IEC 60730-2-14:2017 | Automatic electrical controls - Part 2-14: Particular requirements for electric actuators |
EN ISO 228-1:2003 | Pipe threads where pressure-tight joints are not made on the threads - Part 1: Dimensions, tolerances and designation (ISO 228-1:2000) |
ISO 7-1:1994 | Pipe threads where pressure-tight joints are made on the threads Part 1: Dimensions, tolerances and designation |
ISO 7005-1:2011 | Pipe flanges — Part 1: Steel flanges for industrial and general service piping systems |
ISO 301:2006 | Zinc alloy ingots intended for castings |
ISO 6952:1994 | Fluid power systems and components Two-pin electrical plug connectors with earth contact Characteristics and requirements |
ISO 228-1:2000 | Pipe threads where pressure-tight joints are not made on the threads Part 1: Dimensions, tolerances and designation |