I.S. EN 60942:2003
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
ELECTROACOUSTICS - SOUND CALIBRATORS
Hardcopy , PDF
03-01-2021
English
01-01-2003
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Reference environmental conditions
5 Requirements
5.1 General
5.2 Sound pressure level
5.3 Frequency
5.4 Influence of static pressure, air temperature
and humidity
5.5 Total distortion
5.6 Power supply requirements
5.7 Specification and calibration of microphones
5.8 Electromagnetic compatibility
6 Instrument marking and documentation
6.1 Marking of the sound calibrator
6.2 Individual calibration chart for a class LS
sound calibrator
6.3 Instruction manual
Annex A (normative) - Pattern evaluation tests
A.0 Introduction
A.1 Submission for test
A.2 Principal values
A.3 Marking of the sound calibrator and supplied
documentation
A.4 Performance tests at and around reference
environmental conditions
A.5 Environmental tests
A.6 Electromagnetic compatibility
Annex B (normative) - Periodic tests
B.0 Introduction
B.1 Submission for test
B.2 Preliminary inspection
B.3 Performance tests
B.4 Calibration of the sound calibrator with other
models of microphone
B.5 Documentation
Annex C (normative) - Format for the pattern
evaluation report
C.0 Introduction
C.1 Marking
C.2 Submission for test
C.3 Pattern evaluation report
Bibliography
Provides the performance requirements for three classes of sound calibrator: laboratory standard (class LS), class 1 and class 2.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
192
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Withdrawn
|
Standards | Relationship |
UNE-EN 60942:2005 | Identical |
DIN EN 60942:2004-05 | Identical |
BS EN 60942:2003 | Identical |
EN 60942:2003 | Identical |
NBN EN 60942 : 2004 | Identical |
IEC 60942:2003 | Identical |
SN EN 60942 : 2003 | Identical |
NF EN 60942 : 2003 | Identical |
EN 61000-6-1:2007 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments |
IEC 61094-5:2016 | Electroacoustics - Measurement microphones - Part 5: Methods for pressure calibration of working standard microphones by comparison |
EN 61094-5:2016 | Electroacoustics - Measurement microphones - Part 5: Methods for pressure calibration of working standard microphones by comparison |
EN 61094-4:1995 | Measurement microphones - Part 4: Specifications for working standard microphones |
EN 61000-6-3:2007/A1:2011/AC:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-3: GENERIC STANDARDS - EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS (IEC 61000-6-3:2006/A1:2010) |
IEC 61000-6-2:2016 | Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
OIML R 97 : 1990 | BAROMETERS |
IEC 61094-4:1995 | Measurement microphones - Part 4: Specifications for working standard microphones |
ISO 266:1997 | Acoustics — Preferred frequencies |
EN 61094-1:2000 | Measurement microphones - Part 1: Specifications for laboratory standard microphones |
IEC 61094-1:2000 | Measurement microphones - Part 1: Specifications for laboratory standard microphones |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
EN 61094-2:2009 | Electroacoustics - Measurement microphones - Part 2: Primary method for pressure calibration of laboratory standard microphones by the reciprocity technique |
IEC 60050-801:1994 | International Electrotechnical Vocabulary (IEV) - Part 801: Acoustics and electroacoustics |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
IEC 61000-6-3:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments |
EN 61672-1:2013 | Electroacoustics - Sound level meters - Part 1: Specifications |
EN 55022:2010/AC:2011 | INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008) |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 61000-6-1:2016 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments |
IEC 61094-2:2009 | Electroacoustics - Measurement microphones - Part 2: Primary method for pressure calibration of laboratory standard microphones by the reciprocity technique |
CISPR 16-1:1999+AMD1:2002 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1: Radio disturbance and immunity measuring apparatus |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.