I.S. EN 60976:2007
Current
The latest, up-to-date edition.
MEDICAL ELECTRICAL EQUIPMENT - MEDICAL ELECTRON ACCELERATORS - FUNCTIONAL PERFORMANCE CHARACTERISTICS
Hardcopy , PDF
English
01-01-2007
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Environmental conditions
4.1 General
4.2 Transport and storage
4.3 Power supply
5 General information to the USER
5.1 Functional performance characteristics
5.2 Available nominal energies and ABSORBED DOSE RATES
5.3 Available RADIATION FIELDS
5.4 NORMAL TREATMENT DISTANCE
5.5 Available WEDGE X-RAY FIELDS
5.6 Available flattening FILTERS
5.7 Availability
5.8 Influencing quantities
5.9 Maintenance
5.10 Presentation
5.11 Dimensions, clearances, within the RADIATION HEAD, and
in the region RADIATION HEAD to ISOCENTRE, of BEAM
LIMITING DEVICES
5.12 IMRT
6 Standardized test conditions
6.1 General
6.2 Angle settings
6.3 Properties and positioning of the PHANTOM
6.4 Positioning of measuring points
6.5 RADIATION DETECTORS
6.6 STANDARD MEASUREMENT DEPTHS
6.7 RADIATION FIELDS
6.8 Adjustments during test
6.9 Use of RADIOGRAPHIC FILM or alternative imaging method
7 DOSE MONITORING SYSTEM
7.1 General
7.2 Reproducibility
7.3 Proportionality
7.4 Dependence on angular positions
7.5 Dependence on GANTRY rotation
7.6 Dependence on the shape of the RADIATION FIELD
7.7 Stability of calibration
7.8 Stability in MOVING BEAM RADIOTHERAPY
8 Depth ABSORBED DOSE characteristics
8.1 X-RADIATION
8.2 ELECTRON RADIATION
9 Uniformity of RADIATION FIELDS
9.1 X-RADIATION
9.2 ELECTRON RADIATION
9.3 PENUMBRA of RADIATION FIELDS
10 Indication of RADIATION FIELDS
10.1 X-RADIATION
10.2 ELECTRON RADIATION
10.3 Geometry and motion speeds of adjustable BLDs for
X-RADIATION and ELECTRON RADIATION
10.4 Illuminance and PENUMBRA of the LIGHT FIELD
11 Indication of the RADIATION BEAM AXIS
11.1 General
11.2 Indication on entry to the PATIENT
11.3 Indication on exit from the PATIENT
12 ISOCENTRE
12.1 Displacement of the RADIATION BEAM AXIS from the
ISOCENTRE
12.2 Indication of the ISOCENTRE
13 Indication of distance along the RADIATION BEAM AXIS
13.1 Indicating device
13.2 Additional indicating device for equipment with
variable distance between RADIATION SOURCE and
ISOCENTRE and for non-isocentric equipment
14 Zero position of rotational scales
14.1 General
14.2 Information to the USER
14.3 Tests
15 Congruence of opposed RADIATION FIELDS
15.1 Information to the USER
15.2 Test
16 Movements of the PATIENT table
16.1 General
16.2 Vertical movement of the table
16.3 ISOCENTRIC rotation of the table
16.4 Parallelism of table rotational axes
16.5 Rigidity of the table
17 ELECTRONIC IMAGING DEVICE (e.g. EPID)
17.1 Information to the USER
17.2 Tests
Annex A (informative) Format for presentation of functional
performances values
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Index of defined terms
Applicable to medical ELECTRON ACCELERATORS when used, for therapy purposes, in human medical practice.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
210
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Standards | Relationship |
NF EN 60976 : 2008 | Identical |
SN EN 60976 : 1999 AMD 1 2000 | Identical |
EN 60976:2007 | Identical |
UNE-EN 60976:2008 | Identical |
NBN EN 60976 : 2008 | Identical |
DIN EN 60976:2011-02 | Identical |
BS EN 60976 : 2008 | Identical |
IEC 60976:2007 | Identical |
EN 61217:2012 | Radiotherapy equipment - Coordinates, movements and scales |
IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
IEC TR 60788:2004 | Medical electrical equipment - Glossary of defined terms |
IEC TR 60977:2008 | Medical electrical equipment - Medical electron accelerators - Guidelines for functional performance characteristics |
IEC 60580:2000 | Medical electrical equipment - Dose area product meters |
IEC 60601-2-1:2009+AMD1:2014 CSV | Medical electrical equipment - Part 2-1: Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV |
IEC 61217:2011 | Radiotherapy equipment - Coordinates, movements and scales |
EN 60580:2000 | Medical electrical equipment - Dose area product meters |
EN 60601-2-1:2015 | Medical electrical equipment - Part 2-1: Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.