I.S. EN 61005:2017
Current
The latest, up-to-date edition.
RADIATION PROTECTION INSTRUMENTATION - NEUTRON AMBIENT DOSE EQUIVALENT (RATE) METERS
Hardcopy , PDF
English
01-01-2017
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
National Foreword
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions, abbreviations and symbols,
quantities and units
4 General test procedure
5 General requirements
6 Radiation detection requirements
7 Additivity of indicated value
8 Software
9 Electrical characteristics
10 Environmental requirements
11 Mechanical requirements
12 Electromagnetic requirements
13 Documentation
Annex A (informative) - Neutron fluence-to-ambient dose
equivalent conversion coefficients
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Pertains to assemblies designed to measure the ambient dose equivalent (rate) due to neutron radiation in fields that contain neutrons with energies below 20 MeV, and which comprise at least: a) a detection assembly, which may, for example, consist of a detector probe for thermal neutrons and an arrangement of neutron moderating and absorbing media surrounding the detector; b) a measuring assembly with a display for the measured quantity, which may be incorporated into a single assembly with the detector or connected to it by means of a flexible cable.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
120
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Standards | Relationship |
DIN EN 61005 : 2017 | Identical |
NF EN 61005 : 2017 | Identical |
NBN EN 61005 : 2006 | Identical |
BS EN 61005:2004 | Identical |
EN 61005:2017 | Identical |
IEC TR 62461:2015 | Radiation protection instrumentation - Determination of uncertainty in measurement |
IEC 61187:1993 | Electrical and electronic measuring equipment - Documentation |
ISO 8529-3:1998 | Reference neutron radiations — Part 3: Calibration of area and personal dosimeters and determination of response as a function of energy and angle of incidence |
ISO 4037-2:1997 | X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 2: Dosimetry for radiation protection over the energy ranges from 8 keV to 1,3 MeV and 4 MeV to 9 MeV |
ISO/IEC Guide 99:2007 | International vocabulary of metrology Basic and general concepts and associated terms (VIM) |
ISO 8529-2:2000 | Reference neutron radiations Part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field |
ISO 12789-2:2008 | Reference radiation fields — Simulated workplace neutron fields — Part 2: Calibration fundamentals related to the basic quantities |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 60086-1:2015 | Primary batteries - Part 1: General |
IEC 60086-2:2015 | Primary batteries - Part 2: Physical and electrical specifications |
EN 60086-2:2016 | Primary batteries - Part 2: Physical and electrical specifications |
IEC 60086-1:2015 | Primary batteries - Part 1: General |
ISO 4037-1:1996 | X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 1: Radiation characteristics and production methods |
ISO 8529-1:2001 | Reference neutron radiations Part 1: Characteristics and methods of production |
EN 61187:1994/corrigendum:1995 | ELECTRICAL AND ELECTRONIC MEASURING EQUIPMENT - DOCUMENTATION |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
ISO 11929:2010 | Determination of the characteristic limits (decision threshold, detection limit and limits of the confidence interval) for measurements of ionizing radiation Fundamentals and application |
ISO 4037-3:1999 | X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence |
ISO 12789-1:2008 | Reference radiation fields — Simulated workplace neutron fields — Part 1: Characteristics and methods of production |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.