FOREWORD
1 General data
1.1 Scope
1.2 Normative references
1.3 IEC type designation
2 Terminology
3 Dimensional information
3.1 Common features
3.2 General
3.3 Contact arrangement of all connector types
3.4 IP65 and IP67 sealing
3.5 Industrial IEC 60603-7 variant 01 - bayonet coupling
3.6 Industrial IEC 60603-7 variant 02 - snap-in coupling
3.7 Industrial IEC 60603-7 variant 03 - threaded coupling
3.8 Industrial IEC 60603-7 variant 04 - snap-in coupling
3.9 Industrial IEC 60603-7 variant 05 - locking lever coupling
3.10 Industrial IEC 60603-7 variant 06 - snap-in coupling
3.11 Industrial IEC 60603-7 variant 07 - locking lever coupling
3.12 Industrial IEC 60603-7 variant 08 - threaded coupling
3.13 Industrial IEC 60603-7 variant 09 - quarter turn coupling
3.14 Industrial IEC 60603-7 variant 10 - Pulse lock coupling
3.15 Termination and mounting information
3.16 Mounting information for variant 01, fixed connector
3.17 Mounting information for variant 02, fixed connector
3.18 Mounting information for variant 03, fixed connector
3.19 Mounting information for variant 04, fixed connector
3.20 Mounting information for variant 05, fixed connector
3.21 Mounting information for variant 06, fixed connector
3.22 Mounting information for variant 07, fixed connector
3.23 Mounting information for variant 08, fixed connector
3.24 Mounting information for variant 09, fixed connector
3.25 Mounting information for variant 10, fixed connector
4 Gauges - Connectors for the IEC 60603-7 interface
5 Characteristics
5.1 Climatic category
5.2 Electrical
5.3 Transmission characteristics
5.4 Mechanical
6 Test schedule
6.1 General
6.2 Test procedures and measuring methods
6.3 Preconditioning
6.4 Wiring and mounting of specimens
6.5 Arrangement for contact resistance test:
6.6 Arrangement for dynamic stress tests (test phase AP2)
6.7 Basic (minimum) test schedule
6.8 Full test schedule
Annex ZA (normative) Normative references to international
publications with their corresponding European publications
Covers protective housings for upgrading existing 8-way shielded and unshielded connectors utilizing the interface described in the IEC 60603-7 series to IP65 and IP67 ratings according to IEC 60529, for use in industrial environments.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
114
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NF EN 61076-3-106 : 2007 | Identical |
NBN EN 61076-3-106 : 2007 | Identical |
BS EN 61076-3-106:2006 | Identical |
EN 61076-3-106 : 2006 | Identical |
DIN EN 61076-3-106:2007-07 | Identical |
IEC 61076-3-106:2006 | Identical |
IEC 61076-1:2006 | Connectors for electronic equipment - Product requirements - Part 1: Generic specification |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 60512-1-100:2012 | Connectors for electronic equipment - Tests and measurements - Part 1-100: General - Applicable publications |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
EN 61076-1:2006 | Connectors for electronic equipment - Product requirements - Part 1: Generic specification |
IEC 61156-2:2010 | Multicore and symmetrical pair/quad cables for digital communications - Part 2: Symmetrical pair/quad cables with transmission characteristics up to 100 MHz - Horizontal floor wiring - Sectional specification |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60512-1-100:2012 | Connectors for electronic equipment - Tests and measurements - Part 1-100: General - Applicable publications |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 61156-4:2009 | Multicore and symmetrical pair/quad cables for digital communications - Part 4: Riser cables - Sectional specification |
IEC 61156-3:2008 | Multicore and symmetrical pair/quad cables for digital communications - Part 3: Work area cable - Sectional specification |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 60050-581:2008 | International Electrotechnical Vocabulary (IEV) - Part 581: Electromechanical components for electronic equipment |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.