I.S. EN 61268:1999
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
ALTERNATING CURRENT STATIC VAR-HOUR METERS FOR REACTIVE ENERGY (CLASSES 2 AND 3)
Hardcopy , PDF
21-05-2003
English
01-01-1999
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
1 Scope
2 Normative references
3 Definitions
3.1 General definitions
3.2 Definitions related to the functional elements
3.3 Definitions of mechanical elements
3.4 Definitions of insulations
3.5 Definitions of meter quantities
3.6 Definitions of influence quantities
3.7 Definition of tests
4 Requirements
4.1 Standard electrical values
4.2 Mechanical requirements
4.3 Climatic conditions
4.4 Electrical requirements
4.5 Electromagnetic compatibility (EMC)
4.6 Accuracy requirements
5 Tests and test conditions
5.1 General testing procedures
5.2 Tests of mechanical requirements
5.3 Tests of climatic influences
5.4 Tests of electrical requirements
5.5 Tests for electromagnetic compatibility (EMC)
5.6 Tests for accuracy requirements
Tables
1 Standard reference voltages
2 Standard reference currents
3 Clearances and creepage distances for the terminal
block
4 Voltage marking
5 Temperature range
6 Relative humidity
7 Voltage range
8 Variations due to short-time overcurrents
9 Variations due to self-heating
10 Percentage error limits (single-phase meters and
polyphase meters with balanced loads)
11 Percentage error limits (polyphase meters carrying
a single-phase load, but with balanced polyphase
voltages applied to voltage circuits)
12 Influence quantities
13 Temperature coefficient
14 Starting current
15 A.C. voltage tests
16 Voltage and current balance
17 Reference conditions
18 Interpretation of test results
Annexes
A Relationship between ambient air temperature and
relative humidity
B Test circuit diagram for d.c. influence test
C Voltage waveform for the tests of the effect of
voltage dips and short interruptions
D Electromagnet for testing the influence of
externally produced magnetic fields
E Geometric representation of active and reactive
power
F Test schedule
ZA (normative) Normative references to international
publications with their corresponding European
publications
ZB (normative) Special national conditions
Applies only to newly manufactured static var-hour meters of accuracy classes 2 and 3 for the measurement of alternating current electrical reactive energy of a frequency in the range 45 Hz to 65 Hz and, like IEC 60687 and IEC 61036.
DocumentType |
Standard
|
Pages |
104
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
DIN EN 61268 : 1996 | Identical |
IEC 61268:1995 | Identical |
SN EN 61268 : 1996 | Identical |
EN 61268:1996 | Identical |
UNE-EN 61268:1996 | Identical |
NBN EN 61268 : 1996 | Identical |
NF EN 61268 : 1996 | Identical |
BS EN 61268:1996 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.