I.S. EN 61850-8-1:2011
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
COMMUNICATION NETWORKS AND SYSTEMS FOR POWER UTILITY AUTOMATION - PART 8-1: SPECIFIC COMMUNICATION SERVICE MAPPING (SCSM) - MAPPINGS TO MMS (ISO 9506-1 AND ISO 9506-2) AND TO ISO/IEC 8802-3
Hardcopy , PDF
English
01-01-2011
13-05-2020
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Abbreviations
5 Overview
6 Communication stack
7 Objects of IEC 61850
8 Mapping of IEC 61850-7-2 and IEC 61850-7-3 data
attributes
9 Server class model
10 Association model
11 Logical device model
12 Logical node model
13 DataObject, DataAttribute, SubDataAttribute model
14 Data set class model
15 Service Tracking model
16 Setting group control class model
17 Reporting and logging class model
18 Mapping of the generic substation event model (GSE)
19 Transmission of sampled values class model
20 Control class model
21 Time and time synchronization model
22 Naming conventions
23 File transfer
24 Conformance
25 Substation Configuration Language (SCL)
Annex A (normative) - Application protocol specification
for GOOSE and GSE management
Annex B (informative) - Multicast address selection
Annex C (normative) - Overview of ISO/IEC 8802-3 frame
structure for GSE management and GOOSE
Annex D (informative) - SCL conformance
Annex E (informative) - Time scales and epochs
Annex F (normative) - Type extensions to ISO 9506-1:2003
and ISO 9506-2:2003
Annex G (informative) - Example SCL File
Annex H (informative) - Generic Substation State Event
(GSSE)
Annex I (informative) - Certificate management
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Describes a method of exchanging time-critical and non-time-critical data through local-area networks by mapping ACSI to MMS and ISO/IEC 8802-3 frames.
| DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
| DocumentType |
Standard
|
| Pages |
199
|
| PublisherName |
National Standards Authority of Ireland
|
| Status |
Superseded
|
| SupersededBy |
| Standards | Relationship |
| IEC 61850-8-1:2011 | Identical |
| DIN EN 61850-8-1:2012-02 | Identical |
| BS EN 61850-8-1:2011 | Identical |
| NF EN 61850-8-1 : 2012 | Identical |
| NBN EN 61850-8-1 : 2011 | Identical |
| EN 61850-8-1:2011 | Identical |
| UNE-EN 61850-8-1:2011 | Equivalent |