• I.S. EN 61952:2008

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    INSULATORS FOR OVERHEAD LINES - COMPOSITE LINE POST INSULATORS FOR A.C. SYSTEMS WITH A NOMINAL VOLTAGE GREATER THAN 1 000 V - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA

    Available format(s):  Hardcopy, PDF

    Withdrawn date:  31-10-2018

    Language(s):  English

    Published date:  11-12-2008

    Publisher:  National Standards Authority of Ireland

    For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
    Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

    Dates of withdrawal of national standards are available from NSAI.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Abbreviations
    5 Identification
    6 Environmental conditions
    7 Transport, storage and installation
    8 Tolerances
    9 Classification of tests
       9.1 Design tests
       9.2 Type tests
       9.3 Sample tests
       9.4 Routine tests
    10 Design tests
       10.1 General
       10.2 Test specimens for IEC 62217
            10.2.1 Tests on interfaces and connections of end fittings
            10.2.2 Tracking and erosion test
            10.2.3 Tests on core material
       10.3 Product specific pre-stressing for IEC 62217 tests on
            interfaces and connections of end fittings
            10.3.1 Thermal-mechanical pre-stressing
       10.4 Assembled core load tests
            10.4.1 Test for the verification of the maximum design
                   cantilever load (MDCL)
            10.4.2 Tensile load test
    11 Type tests
       11.1 Electrical tests
            11.1.1 Vertical mounting arrangement
            11.1.2 Horizontal mounting arrangement
       11.2 Mechanical tests
            11.2.1 Cantilever failing load test
    12 Sample tests
       12.1 General rules
       12.2 Verification of dimensions (E1 + E2)
       12.3 Galvanizing test (E1 + E2)
       12.4 Verification of the SCL (E1)
            12.4.1 Test procedure
            12.4.2 Acceptance criteria
       12.5 Re-testing procedure
    13 Routine tests
       13.1 Tensile load test
       13.2 Visual examination
    Annex A (informative) Notes on the mechanical loads
            and tests
    Annex B (informative) Determination of the equivalent
            bending moment caused by combined loads
    Annex ZA (normative) Normative references to international
             publications with their corresponding European
             publications
    Bibliography

    Abstract - (Show below) - (Hide below)

    Applicable to composite line post insulators consisting of a load-bearing cylindrical insulating solid core consisting of fibres - usually glass - in a resin-based matrix, a housing (outside the insulating core) made of polymeric material and end fittings permanently attached to the insulating core.

    General Product Information - (Show below) - (Hide below)

    Development Note For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
    Document Type Standard
    Publisher National Standards Authority of Ireland
    Status Withdrawn

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61467:2008 Insulators for overhead lines - Insulator strings and sets for lines with a nominal voltage greater than 1 000 V - AC power arc tests
    IEC 60050-471:2007 International Electrotechnical Vocabulary (IEV) - Part 471: Insulators
    IEC 62217:2012 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
    IEC 60383-1:1993 Insulators for overhead lines with a nominal voltage above 1000 V - Part 1: Ceramic or glass insulator units for a.c. systems - Definitions, test methods and acceptance criteria
    EN 60383-1:1996/A11:1999 INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1 KV - CERAMIC OR GLASS INSULATOR UNITS FOR A.C. SYSTEMS - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
    IEC 61462:2007 Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1 000 V - Definitions, test methods, acceptance criteria and design recommendations
    IEC GUIDE 111:2004 Electrical high-voltage equipment in high-voltage substations - Common recommendations for product standards
    IEC 60507:2013 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
    EN 62217:2013 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
    IEC 60383-2:1993 Insulators for overhead lines with a nominal voltage above 1000 V - Part 2: Insulator strings and insulator sets for a.c. systems - Definitions, test methods and acceptance criteria
    EN 60383-2:1995 Insulators for overhead lines with a nominal voltage above 1 kV - Part 2: Insulator strings and insulator sets for a.c. systems - Definitions, test methods and acceptance criteria
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications