I.S. EN 62439:2008
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
HIGH AVAILABILITY AUTOMATION NETWORKS
Hardcopy , PDF
01-03-2010
I.S. EN 62439-4:2010
I.S. EN 62439-1:2010
I.S. EN 62439-5:2010
I.S. EN 62439-6:2010
I.S. EN 62439-3:2012
I.S. EN 62439-2:2010
English
01-01-2008
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions, abbreviated terms, acronyms, and conventions
3.1 Terms and definitions
3.2 Abbreviated terms and acronyms
3.3 Conventions
3.3.1 General conventions
3.3.2 Conventions for state machine definitions
3.3.3 Conventions for PDU specification
3.4 Reserved network addresses
4 Concepts for high availability automation networks
4.1 Characteristics of application of automation networks
4.1.1 Resilience in case of failure
4.1.2 Classes of network redundancy
4.1.3 Redundancy maintenance
4.1.4 Comparison and indicators
4.2 Generic network system
4.2.1 Network elements
4.2.2 Topologies
4.2.3 Redundancy handling
4.2.4 Network recovery time
4.2.5 Diagnosis coverage
4.2.6 Failures
4.3 Safety
4.4 Security
4.5 Conformance
4.5.1 Conformance to redundancy protocols
4.5.2 Conformance tests
5 MRP - Media Redundancy Protocol based on a ring topology
5.1 MRP Overview
5.2 MRP Media redundancy behaviour
5.2.1 Ring ports
5.2.2 Media Redundancy Manager (MRM)
5.2.3 Media Redundancy Client (MRC)
5.2.4 Redundancy domain
5.2.5 Usage with diagnosis and alarms
5.2.6 Ring diagnosis
5.2.7 Multiple MRM in a single ring
5.2.8 BLOCKED not supported (option)
5.3 MRP Class specification
5.3.1 General
5.3.2 Template
5.3.3 Attributes
5.4 MRP Service specification
5.4.1 Start MRM
5.4.2 Stop MRM
5.4.3 State Change
5.4.4 Start MRC
5.4.5 Stop MRC
5.4.6 Read MRM
5.4.7 Read MRC
5.5 MRP Protocol specification
5.5.1 PDU description
5.5.2 Protocol machines
5.6 MRP Installation, configuration and repair
5.6.1 Ring port parameters
5.6.2 Ring topology parameters
5.6.3 MRM and MRC parameters
5.6.4 Configuration
6 PRP - Parallel Redundancy Protocol
6.1 PRP Principle of operation
6.1.1 Single points of failure
6.1.2 Node structure
6.1.3 Compatibility between singly and doubly attached nodes
6.1.4 Network management
6.1.5 Transition to non-redundant networks
6.1.6 Duplicate handling
6.1.7 Configuration check
6.1.8 Network supervision
6.1.9 Redundancy management interface
6.2 PRP protocol specifications
6.2.1 Installation, configuration and repair guidelines
6.2.2 MAC addresses
6.2.3 Multicast MAC addresses
6.2.4 IP addresses
6.2.5 Nodes
6.2.6 Duplicate accept mode
6.2.7 Duplicate discard mode
6.3 PRP service specification
6.3.1 Arguments
6.3.2 NodesTable
6.3.3 PRP Write
6.3.4 PRP Read
6.4 PRP Management Information Base
6.5 PRP Protocol Implementation Conformance Statement (PICS)
7 CRP - Cross-network Redundancy Protocol
7.1 CRP Overview
7.2 CRP Nodes
7.3 CRP LAN topology
7.4 CRP Key components
7.4.1 CRP General protocol operation
7.4.2 CRP Statistics
7.4.3 CRP Network_Status_Table
7.4.4 CRP Recovery time
7.4.5 CRP Multicast messages
7.4.6 CRP Unicast messages
7.4.7 CRP Redundancy information
7.4.8 CRP Redundancy statistics
7.5 CRP Protocol
7.5.1 CRP Singly attached node
7.5.2 CRP Doubly attached node
7.5.3 CRP Installation, configuration and repair
7.5.4 CRP LRE model attributes
7.5.5 CRP Encoding of the DiagnosticFrame
7.5.6 CRP Encoding of the AnnunciationFrame
7.5.7 CRP Common protocol
7.5.8 CRP Operational messages
7.5.9 CRP services
8 BRP - Beacon redundancy protocol
8.1 BRP Overview
8.2 BRP Principle of operation
8.2.1 General
8.2.2 Network topology
8.2.3 Network components
8.2.4 Rapid reconfiguration of network traffic
8.3 BRP stack and fault detection features
8.4 BRP Protocol specification
8.4.1 MAC addresses
8.4.2 EtherType
8.4.3 Fault detection mechanisms
8.4.4 End node state diagram
8.4.5 Beacon end node state diagram
8.5 BRP Message structure
8.5.1 General
8.5.2 IEEE 802.3 tagged frame header
8.5.3 Beacon message
8.5.4 Learning_Update message
8.5.5 Failure_Notify message
8.5.6 Path_Check_Request message
8.5.7 Path_Check_Response message
8.6 BRP Fault recovery time
8.7 BRP Service definition
8.7.1 Supported services
8.7.2 Common service parameters
8.7.3 Set node parameters service
8.7.4 Get node parameters service
8.7.5 Add node receive parameters service
8.7.6 Remove node receive parameters service
8.7.7 Get node status service
Annex A (informative) Classification of networks
Annex B (informative) Availability calculations
Annex C (normative) Network management information base
Annex D (informative) PRP algorithm as pseudo-code
Bibliography
Applies to high-availability automation networks based on the ISO/IEC 8802-3 (Ethernet) technology.
DocumentType |
Standard
|
Pages |
210
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
EN 62439:2008 | Identical |
IEC 62439:2008 | Identical |
IEC 61784-1:2014 | Industrial communication networks - Profiles - Part 1: Fieldbus profiles |
ISO/IEC 15802-3:1998 | Information technology Telecommunications and information exchange between systems Local and metropolitan area networks Common specifications Part 3: Media Access Control (MAC) Bridges |
IEEE 802-2014 | IEEE Standard for Local and Metropolitan Area Networks: Overview and Architecture |
IEEE 802.3-2012 | IEEE Standard for Ethernet |
ISO/IEC 11801:2002 | Information technology Generic cabling for customer premises |
IEEE 802.1Q-2014 | IEEE Standard for Local and metropolitan area networks--Bridges and Bridged Networks |
IEEE 802A : 2003 | LOCAL AND METROPOLITAN AREA NETWORKS: OVERVIEW AND ARCHITECTURE - AMENDMENT 1: ETHERTYPES FOR PROTOTYPE AND VENDOR-SPECIFIC PROTOCOL DEVELOPMENT |
IEEE 802.1D-2004 | IEEE Standard for Local and metropolitan area networks: Media Access Control (MAC) Bridges |
ISO/IEC 10731:1994 | Information technology Open Systems Interconnection Basic Reference Model Conventions for the definition of OSI services |
IEC 61918:2013 | Industrial communication networks - Installation of communication networks in industrial premises |
IEC 60050-603:1986 | International Electrotechnical Vocabulary (IEV) - Part 603: Generation, transmission and distribution of electricity - Power systems planning and management |
EN 61918:2013/AC:2014 | INDUSTRIAL COMMUNICATION NETWORKS - INSTALLATION OF COMMUNICATION NETWORKS IN INDUSTRIAL PREMISES (IEC 61918:2013, MODIFIED) |
EN 61784-2:2014 | Industrial communication networks - Profiles - Part 2: Additional fieldbus profiles for real-time networks based on ISO/IEC 8802-3 |
IEEE 1588-2008 REDLINE | IEEE Standard for a Precision Clock Synchronization Protocol for Networked Measurement and Control Systems |
ISO/IEC 14496-4:2004 | Information technology — Coding of audio-visual objects — Part 4: Conformance testing |
EN 61784-1:2014 | Industrial communication networks - Profiles - Part 1: Fieldbus profiles |
IEC 61784-2:2014 | Industrial communication networks - Profiles - Part 2: Additional fieldbus profiles for real-time networks based on ISO/IEC 8802-3 |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.