• I.S. EN 62585:2012

    Current The latest, up-to-date edition.

    ELECTROACOUSTICS - METHODS TO DETERMINE CORRECTIONS TO OBTAIN THE FREE-FIELD RESPONSE OF A SOUND LEVEL METER (IEC 62585:2012 (EQV))

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  01-01-2012

    Publisher:  National Standards Authority of Ireland

    For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
    Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

    Dates of withdrawal of national standards are available from NSAI.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Reference environmental conditions
    5 Uncertainties of measurement
    6 General requirements for measurement of
       adjustment value and corrections
    7 Submission and inspection
    8 Determination of the adjustment value at
       the calibration check frequency
    9 Determination of corrections for the typical
       effects of reflections from the case of the sound
       level meter and diffraction of sound around the
       microphone
    10 Determination of corrections for the deviation
       of the microphone free-field frequency response
       from a uniform frequency response
    11 Determination of corrections for the use of
       windscreens and similar accessories
    12 Determination of corrections over a range of
       frequencies when a sound calibrator is recommended
       for use by the sound level meter manufacturer
    13 Determination of corrections over a range of
       frequencies when a comparison coupler is
       recommended for use by the sound level meter
       manufacturer
    14 Determination of corrections over a range of
       frequencies when an electrostatic actuator is
       recommended for use by the sound level meter
       manufacturer
    15 Documentation
    Annex A (normative) - Calibration check frequency
            - Determination of the adjustment value
    Annex B (normative) - Determination of the effects
            of reflections from the case of the sound level
            meter and diffraction of sound around the
            microphone
    Annex C (normative) - Determination of the effects
            of the use of windscreens and similar accessories
    Annex D (informative) - Determination of corrections
            for use with sound calibrators to determine
            equivalent free-field response at all frequencies
            of interest
    Annex E (informative) - Determination of corrections
            for use with comparison couplers to determine
            equivalent free-field frequency response at all
            frequencies of interest
    Annex F (informative) - Determination of corrections
            for use with electrostatic actuators to determine
            equivalent free-field frequency response at all
            frequencies of interest
    Annex G (informative) - Comparison techniques
    Annex H (informative) - Exact one-twelfth-octave
            frequencies
    Annex I (informative) - Example calculations of
            expanded uncertainty of measurement
    Bibliography
    Annex ZA (normative) - Normative references to
             international publications with their
             corresponding European publications

    Abstract - (Show below) - (Hide below)

    Gives information on the corrections required over a range of frequencies in order for a periodic test of a sound level meter to be performed according to IEC 61672-3.

    General Product Information - (Show below) - (Hide below)

    Development Note For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
    Document Type Standard
    Publisher National Standards Authority of Ireland
    Status Current

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61672-2:2013+AMD1:2017 CSV Electroacoustics - Sound level meters - Part 2: Pattern evaluation tests
    IEC 61094-5:2016 Electroacoustics - Measurement microphones - Part 5: Methods for pressure calibration of working standard microphones by comparison
    IEC 61183:1994 Electroacoustics - Random-incidence and diffuse-field calibration of sound level meters
    IEC TS 61094-7:2006 Measurement microphones - Part 7: Values for the difference between free-field and pressure sensitivity levels of laboratory standard microphones
    IEC 60942:2003 Electroacoustics - Sound calibrators
    IEC 61094-1:2000 Measurement microphones - Part 1: Specifications for laboratory standard microphones
    IEC 61094-3:2016 Electroacoustics - Measurement microphones - Part 3: Primary method for free-field calibration of laboratory standard microphones by the reciprocity technique
    ISO/IEC Guide 99:2007 International vocabulary of metrology Basic and general concepts and associated terms (VIM)
    IEC 61094-8:2012 Measurement microphones - Part 8: Methods for determining the free-field sensitivity of working standard microphones by comparison
    IEC 61094-2:2009 Electroacoustics - Measurement microphones - Part 2: Primary method for pressure calibration of laboratory standard microphones by the reciprocity technique
    IEC 61672-3:2013 Electroacoustics - Sound level meters - Part 3: Periodic tests
    IEC 61094-6:2004 Measurement microphones - Part 6: Electrostatic actuators for determination of frequency response
    IEC 61260:1995 Electroacoustics - Octave-band and fractional-octave-band filters
    ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective