• I.S. EN 771-1:2011

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    SPECIFICATION FOR MASONRY UNITS - PART 1: CLAY MASONRY UNITS

    Available format(s):  Hardcopy, PDF

    Withdrawn date:  07-09-2015

    Language(s):  English

    Published date:  12-05-2011

    Publisher:  National Standards Authority of Ireland

    For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
    Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

    Dates of withdrawal of national standards are available from NSAI.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    National Foreword
    European foreword
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Materials and manufacture
    5 Requirements for clay masonry units
    6 Description, designation, designation code
      and classification of clay masonry units'
    7 Marking
    8 Assessment and verification of constancy of performance
      (AVCP)'
    Annex A (normative) - Sampling for product type
            determination tests and for independent
            testing of consignments'
    Annex B (informative) - Additional information
    Annex C (informative) - Guidelines for test frequencies
            for designing a FPC system to demonstrate conformity
             of finished products with the requirements of
             the standard and the declaration of the manufacturer
    Annex ZA (informative) - Clauses of this European Standard
             addressing the provisions of the EU Construction
             Products Regulation'
    Bibliography

    Abstract - (Show below) - (Hide below)

    Defines the characteristics and performance requirements for masonry units manufactured from clay for which the main intended uses are protected or unprotected masonry structure (e.g. facing and rendered masonry, loadbearing or non-loadbearing masonry structures, including internal linings and partitions, for building and civil engineering).

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes I.S. 91, I.S. 189 & I.S. 190. (11/2010) 2011 Edition Re-Issued in September 2015 & incorporates AMD 1 2015. (09/2015)
    Document Type Standard
    Publisher National Standards Authority of Ireland
    Status Withdrawn
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    S.R. 325:2013+A2:2018/AC:2019 RECOMMENDATIONS FOR THE DESIGN OF MASONRY STRUCTURES IN IRELAND TO EUROCODE 6

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 998-2:2016 Specification for mortar for masonry - Part 2: Masonry mortar
    EN 772-9:1998/A1:2005 METHODS OF TEST FOR MASONRY UNITS - PART 9: DETERMINATION OF VOLUME AND PERCENTAGE OF VOIDS AND NET VOLUME OF CALCIUM SILICATE MASONRY UNITS BY SAND FILLING
    ISO 12491:1997 Statistical methods for quality control of building materials and components
    EN 772-7:1998 Methods of test for masonry units - Part 7: Determination of water absorption of clay masonry damp proof course units by boiling in water
    EN 772-1:2011+A1:2015 Methods of test for masonry units - Part 1: Determination of compressive strength
    EN 772-19:2000 Methods of test for masonry units - Part 19: Determination of moisture expansion of large horizontally perforated clay masonry units
    EN 1745:2012 Masonry and masonry products - Methods for determining thermal properties
    EN 772-21:2011 Methods of test for masonry units - Part 21: Determination of water absorption of clay and calcium silicate masonry units by cold water absorption
    ISO 12572:2016 Hygrothermal performance of building materials and products Determination of water vapour transmission properties Cup method
    EN 772-5:2016/AC:2017 METHODS OF TEST FOR MASONRY UNITS - PART 5: DETERMINATION OF THE ACTIVE SOLUBLE SALTS CONTENT OF CLAY MASONRY UNITS
    EN 772-16:2011 Methods of test for masonry units - Part 16: Determination of dimensions
    EN ISO 12572:2016 Hygrothermal performance of building materials and products - Determination of water vapour transmission properties - Cup method (ISO 12572:2016)
    EN 1996-1-1:2005+A1:2012 Eurocode 6 - Design of masonry structures - Part 1-1: General rules for reinforced and unreinforced masonry structures
    EN 772-20:2000/A1:2005 METHODS OF TEST FOR MASONRY UNITS - PART 20: DETERMINATION OF FLATNESS OF FACES OF MOSONRY UNITS
    EN 772-3:1998 Methods of test for masonry units - Part 3: Determination of net volume and percentage of voids of clay masonry units by hydrostatic weighing
    EN 1996-3:2006/AC:2009 EUROCODE 6 - DESIGN OF MASONRY STRUCTURES - PART 3: SIMPLIFIED CALCULATION METHODS FOR UNREINFORCED MASONRY STRUCTURES
    EN 1996-1-2:2005/AC:2010 EUROCODE 6 - DESIGN OF MASONRY STRUCTURES - PART 1-2: GENERAL RULES - STRUCTURAL FIRE DESIGN
    EN 1052-3:2002/A1:2007 METHODS OF TEST FOR MASONRY - PART 3: DETERMINATION OF INITIAL SHEAR STRENGTH
    EN 1996-2:2006/AC:2009 EUROCODE 6 - DESIGN OF MASONRY STRUCTURES - PART 2: DESIGN CONSIDERATIONS, SELECTION OF MATERIALS AND EXECUTION OF MASONRY
    EN 772-11:2011 Methods of test for masonry units - Part 11: Determination of water absorption of aggregate concrete, autoclaved aerated concrete, manufactured stone and natural stone masonry units due to capillary action and the initial rate of water absorption of clay masonry units
    EN 772-13:2000 Methods of test for masonry units - Part 13: Determination of net and gross dry density of masonry units (except for natural stone)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective